Weight Measurement Function: By Hours, minutes and seconds unit, Display the status of the usage of liquid gas and it can be used being installed on storage tank or tank lorry and can be carried as a portable measuring instrument. PC Monitoring Function: As the remained liquid goes below 10% of its capacity, it automatically alarms to supplement liquid gas. Thus, the appropriate time for supplement of liquid gas can be decided on time. Alarm Function: the liquid remaining of the storage tank is less than 10%, The alarm sound provides information that you can setting the a liquid supply time. Diversity Of Power Supply: Use the usual 220volt electric, in case of power outage, the built-in battery will supply the charged electricity, in addition built-in battery is operated and available for tank lorry using the car battery. Option (Printer : additional purchase): Receipt Output Function; Portable thermal transfer printer can use the output value measuring of storage tank and tank lorry without visiting a long measuring place directly by the output as a receipt.
Xl5135v-1 ac220v power supply--measuring dc voltage--voltmeter Technical index: Digit display: 1999 Operating temperature:0~40 Relative humidity:20%~80% Power supply:ac220v Installation method:inlay Tapping size:76 x 39 (mm) Dimension: (w) 79mm x (h) 42.5mm x (d) 25.5mm Resolution: 10mv Input impedance: 100mª+ Max. Input voltage:ía10v Full range:ía199.9mv.
1.General PZ96 Series power analyzer specializes in measuring the data of all kinds of AC networks, such as the currents, the voltages, the powers, the energies etc... It may be used for local display, or it is connected with the control equipment in measuring and controlling system. They are a kind of programmable analyzer. With the 4 key on the front, we can set their parameters according to the network which we measure. They have many option functions. They can be equipped RS-485 communication with Modbus-RTU protocol; or they can output analog signal. With logic input or logic output, we can realize controlling other equipment remotely They are a kind of analyzer with excellent cost performance, since they regroup the functions of traditional electric transmitter and digital meters. Therefore they are widely being used in kinds of control system, SCADA system and power management system. 2.Technical feature - Input Network: Single-phase network; 3-phase balanced network, 3-phase unbalanced, 3 wires; 3-phase unbalanced, 4 wires Measurable: 26 parameters (3I, 6U, F, 4P, 4Q, 4cos, 4E) Frequency: 45í½65Hz Voltage: AC 100V, 400V (programmable); Overload: 480V (continuous), 800V/30s; Consumption: < 0.2VA Current: AC 1A, 5A (programmable); Overload: 6A (continuous), 50A/30s; Consumption: < 0.2VA Thermal drift: 100Mª+ - Environment Work T: -10Cí½+45C Storage T: -20Cí½+70C Relative humidity: 5%í½95% (no condensation) Altitude: í_2500m 3.Options - Display (L): LED or LCD display, the brightness can be set - Communication (/C): RS485 (Modbus-RTU); 1 start bit, 8 data bit, 1 stop bit, no parity, speed (1200/2400/4800/9600/19200) - Alarm output(/J): 1 passive relay (1A/30VDC, 1A/250VAC); alarms of over voltage, low voltage and over current; The hysteresis and the delay can be set - Analog output(/M): DC4~20mA, DC0~20mA( load < 600ª+), DC0~5V,DC1~5V( load > 1kª+); Number: /M, /M3 (1 or 3 analog outputs) - Logic options(/K) 4 logic inputs and 2 logic outputs Logic Input: dry contact Input, supplied inside, optoisolator Logic output: NO-NC contact; 1A/30VDC,5A/250VAC ( to control other equipments) - Accuracy: 0.2 Note: /M and /K can not be chosen simultanously. 4. Specification 96 * 96 mm PZ96-E3 3 Phase LED PZ96L-E3 3 Phase LCD 72 * 72 mm PZ72-E Single Phase LED PZ72L-E Single Phase LCD 80 * 80 mm PZ80-E Single Phase LED PZ80-E3 3 Phase LED PZ80L-E Single Phase LED PZ80L-E3 3 Phase LCD 120 * 120 mm PZ42-E3 3 Phase LED PZ42L-E3 3 Phase LCD 144 * 144 mm PZ144-E3 3 Phase LED
The product is used to measure the pH of given aqueous sample.The Range is from 0pH to 14pH.It is given with automatic temperature sensor.
Digital panel meter Digital panel meter which is various and artistic in appearance design is used for dual slope, high precise a/d changeover circuit and high light led cassette setting specification. It is very convenient for user to fix the equipment.
We offer many kinds of industrial measuring instruments and meters, you are welcome to link to: www.Windofwest.Diytrade.Com for more information. Cartons
DEM101 three phase electronic prepayment watt-hour meter Application 1. After power cut down, data reserved forever, The direction of electric power can be distinguished automatically, and has function of anti-stealing electricity. 3. May select many kinds of IC card, have IC card with code and data against false. 4. May select 6 digits LED display or 7 digits LCD display. 5. May select payment controls by kWh or money. Technical parameters Name Type Accuracy Rated voltage) Rated current A) Connection Mode Three phase four wire electronic prepayment watt-hour mete31(2),31.5(6),33(6) Input through current transformer Three phase four wire electronic prepayment watt-hour meter DTSY223(DEM101) Class 1 3380/220 35(25),310(50),315(60),320(80),320(100) Directly input Three phase three wire electronic prepayment watt-hour meter DSSY223(DEM101) Class 1 3380 31(2),31.5(6),33(6) Input through current transformer Three phase three wire electronic prepayment watt-hour meter DSSY223(DEM101) Class 1 3380 35(25),310(50),315(60),320(80),320(100) Directly input
Function random phase measurement, AC current and leak current measurement, AC Voltage detection, distinguish the inductive circuit and capacitive circuit, sequence of three-phase voltage detection and connection group of transformer detection, etc. Power supply DC9V alkaline dry battery LR6f-6 continuous duty :300h LCD 3-1/2 LCD display Dimension Width *length* thick·ª92mmf-192mmf-50mm LCD dimension Display domain·ª64mmf-54mm ·+font high·ª40mm Clamp mouth ¬+7.5mm ·+¬+40mm lectotype·¼ Measuring range phase·ª0~360fp·+current·ª0~200mA/2A/10A·+voltage·ª0~20V/200V/500V resolution phase·ª1fp·+current·ª0.1mA·+voltage·ª0.01V Measurement accuracy ·+50Hz,23f¦f+1f¦·+40-60%RH·¼ phase·ªf+3fp current·ªf+1%f+2dgt Voltage·ªf+1.2%f+2dgt line voltage Line test under AC500V Sampling speed About 3 times /s Signal frequency sine wave 45Hz~55Hz ¬-=0.05 Data hold Data holding function·ªdisplayed by fªDHfª symbol Back light function Blue back light ,suit for dark occasion Automatic shutdown After starting up 15min·+it shutdown automatically to reduce battery consumption Battery voltage When battery voltage is low ,battery low voltage symbol will filker to remind replacing battery; Quality Core about590g·+with battery·¼·+long flat nose current pliers about ·ª175gf-2·+big round tongs clamp·ª120g Work temperature and moisture -10f¦~40f¦·+85%rh below Storage temperature and moisture -20f¦~60f¦·+70%rh below Driving point impedance AC voltage driving point impedance·ª2M¬+·+when test phase U1-U2·ª40K¬+ Insulation intension fª10M¬+9·+Between wire of meter and crust·+two voltage input port·¼ Voltage bear Between port of voltage input and box, split core type currenttransformator and clamp handle& winding coil: 1000V/50Hz, 1min experiment can be reach when sine wave AC voltage 500V/50Hz between port of voltage input. 92*192*50(mm)
DDS22 Single-phase Electronic Watt-hour Meter adopts special large-scale integrated circuit, high-performance parts as well as advanced SMT technology. Therefore, the meter is characterized with high accuracy, tamper-proof function, high anti-interference, and long service life. The meter is easy to operate and can meet the customers' requirements well for its reasonable design. It is the optimum product for customers and public utilities. Functions and Characteristics: Accuracy Class: 1.0class The meter adopts special anti-magnet impulse meter reading mechanical register to prevent strong disturbance form external AC, DC magnetic field. Flat error curve, stable for temperature and time, and reliable. To cumulate both direct and reverse energy, prevent tamper of reversal of lines. Light weight, reliable structure. Easy to be handled and installation. Anti-tamper in condition that load is connected between the line and the earth. The meter can also prevent U ring short circuit and other tampers. Low consumption: ≤ 0.6W Distant-motion-width-determination pulse output and multifunctional output ports . 20units/Pack