Product Description Major technical data: Accuracy class: 1.0 Power consumption: 20 years. Main functions: 1) Measurement of 50hz for 3-phase active power 2) 4 tariffs and 8 time periods for user's option 3) RS 485 communication functions 4) Manual and remote control program, and remote-metering functions 5) To record the parameters automatically through CMRI. Features: 1) High accuracy, reliability, overload capability 2) Low power consumption 3) Smt technology and re-flow soldering technology 4) Light weight, small size, easy to install. Model: DTSF318/DSSF318 Standard: IEC 62052-11 IEC 62053-21 IEC 62056-21 Productivity: 100.000pcs/year.
Single phase long life electronic energy meter Major technical data: Name of product: single phase long life electronic energy meters Type: dds 318 Accuracy class: 1.0 Power consumption :< 6va Rated voltage: 220v 240v Rated current: 2.5(10) a 5(30) a 10(50) a Application: By adopting advanced pcb and smt technology, dds318 single phase long life electronic energy meter is used to measure the energy of 50hz single phase a.C power. Salient feature: 1.High accuracy:1.0class 2.High overload capacity: 6 times of overload. 3.High reliability: long operating life. 4.Low power consumption, small size, light weight, tamper proof and easy to install. 5.Smt and re-flow soldering technology is adopted. Meter has strong capability for disturbance. Emc can comply with requirement of iec61036-2000. 6.With impulse output interface for direct calibration of the meterf+s accuracy, or for measurement of the impulse input in case of mass-metering. 7.Power indicator to test the optical power end and calibrate the accuracy of the meter. 8.Electric power line carrier system and telephone remote-metering system can be supplied for userf+s option. 9.It can be changed into single phase plc electronic energy meter
Features: 1) high accuracy, reliability, overload capability 2) low power consumption 3) smt technology and re-flow soldering technology Major technical data: 1) accuracy class: 1.0 2) power consumption: less than 4va 3) rated voltage: 200v 4) rate current: 2.5(10)a, 5(25)a, 10(40)a Main functions: 1) measurement of single-phase 50hz active power and power consumed 2) set up maximum load, overload warning and power off 3) warning of remained energy and remind user for payment 4) re-read power consumed, remained energy and number of prepayments for power 5) power off when no energy in the meter 6) parameter transferring through ic card Salient features: 1) high accuracy: 1.0 class 2) high overload: 6 times of overload 3) high reliability: long operating life 4) low power consumption, tamper-proof, light weight, small size and easy to install 5) register displays consumed power, and led displays status of consumed power 6) smt technology and re-flow soldering technology are adopted. Meter has strong Capability for disturbance. Emc can comply with requirement of iec 61036-2000 High overload capacity, high reliability of relay Single-phase and 3-phase pre-payment electronic energy meters can share one set Light weight, small size, easy to install Of prepayment control system
DEM031 single phase electronic multi-rate watt-hour meter Application Type DEM031 single phase DIN rail watt-hour meter is a kind of new style single phase electronic multi-rate watt-hour meter, energy data display adopt 7 digits wide temperature type crystal display, with many functions of multi-rate (time-of use) energy measurement, infrared carrier wave communication and RS485 serial port communication reading meter, etc. The meter completely accord with relevant technical requirements of class 1 and class 2 single phase energy meter stipulated in National standard GB/T17215-2002 and international standard IEC61036. it has following features: Good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.1. May select 35mm DIN rail installation or installation on the board. 2. Have 3 tariffs, 12 daily period of times, may select single tariff function in weekend. 3. Inner emplaced clock, after power cut down, the message is preserved forever, inner emplaced spare batteries and free of maintenance. 4. The direction of electric power can be distinguished automatically, accident is checked automatically. 5. Infrared carrier wave communication and RS48 5 serial port communication, meter is set up by program and password is protected. Technical parameters Type Accuracy Rated voltage) Rated current A) Starting Current Insulation Performance DDSF977(DEM031) Class 1 220V 2.5(10),3(15),5(30),10(50),15(90),20(100),5(40),5(100) 0.4%lb AC voltage 2KV for 1 minute impulse voltage 6kv DDSF977(DEM031) Class 2 220V 2.5(10),3(15),5(30),10(50),15(90),20(100),5(40),5(100) 0.5%lb AC voltage 2KV for 1 minute impulse voltage 6kv
DIN-Rail Single Phase Energy Meter with Counter(DDS-1Y-M) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Long terminal block; Nameplate inside; Measure power accurately; Anti-creep. Technical Data: Rated voltage: 110V, 220V, 230V, 240V; Rated current: 5(30)A, 5(60)A, 10(80)A, 5(80)A; Frequency: 50-60Hz Connection mode: Direct type Display: Counter 6+1=999999.9kWh Accuracy Class: 1.0 Power consumption: Un1W (when 220V 20A) Start current: 0.004Ib Standard work temperature: -20-45degree. Crelative humidity: 85%. Size: 115*78*65mm.
Single Phase DIN-Rail Energy Meter (DDS-1Y-L) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 and IEC62056-21(IEC1107) DIN-rail standard: "SO"43864. Function and characteristic: Single measurement(optional RS485 or RS485 Modbus) High accuracy of measure, convenient installation; Logical design of Anti-creep. Technical data: Rated voltage: 110V, 120V, 220V, 230V Rated Current: 1.5(6)A, 5(60)A, 10(100)A Frequency: 50-60Hz Connection mode: CT type; Direct type Display mode: LCD 5+2 = 99999.99kWh Accuracy Class: 1.0 Power consumption: 1W (when 220V 20A) Start current: 0.004Ib Constant: 12800 imp/kWh; 800/1600/3200/6400 imp/kWh Standard work temperature: -20-45 degree Climate work temperature: -30-55 degree Relative humidity: 85%. Size: 100*76*65 mm.
Three Phase Double Tariff Meter (DTS353) Executive Standard: IEC62052-11 2003; IEC62053-21 2003 DIN-rail standard: "SO"43864. Function and characteristic: Two tariffs; Double LCD; Control tariff by exterior controller; Two display window for two different tariffs T1, T2. Technical data: Rated Voltage: 3*220V/380V; 3*230V/400V Rated Current: 3*5(30)A; 3*10(60)A; 3*10(100)A Frequency: 50-60Hz Connection Mode: Direct type Display: LCD 5+1=99999.9kWh Accuracy Class: 1.0; Power Consumption: Less than 0.6W; Less than 0.3VA Start current: 0.004Ib Constant: 800/1600/3200/6400imp/kWh. Size: 122*100*65mm.
Single Phase kWh Meter Executive Standard: IEC62052-11 2003; IEC62053-21 2003 Function and characteristic: Infrared function; Measurement accurately. Technical data: Rated current: 1.5(6)A 5(30)A 10(40)A 5(60)A 20(80)A Rated voltage: 110V 220V 230V 240V Display mode: LCD 6+1=999999.9kWh Accuracy class: 1.0 Frequency: 50Hz (60Hz) Impulse constant: 800/1600imp/kWh Connetion mode: CT type; Direct type. Size: 153*118*50mm.
Stepper motor counters Electronic counters of energy meters 120k one container