The RBBF Clamp-on Ultrasonic Flow Meter is a fixed-mount, low cost transit-time ultrasonic flow meter with clamp-on transducers for non-invasive liquid flow rate measurement. Our microprocessor-based, user friendly field programmable creates no interruption of the process flow and has low installation costs. This versatile series of flow meters is available in a variety of configurations. Available transducer types include clamp-on, in-line, and insertion. Wall-mount, panel-mount, pipe-mounted and compact din-rail mounted display types are also offered. Additional available features include pulse, 0-20mA & 4-20mA outputs, RS-232 communication, user-selectable engineering units, and a data logger function.
Ultrasonic thickness meter Ultrasonic thickness gauge series Tr-8812 /tr-8811 tr-8810 Measuring range:1.0~225mm /1.2~200mm / 1.2~200mm 0.05~9 inch /0.06~8 inch /0.06~8 inch Sound velocity: 500~9000m/s. Resolution : 0.1mm. Accuracy: +/-(0.5%n+0.1).Operating conditions : 0~400c/10~90%rh. Dimensions: 120*62*30mm /160*68*32mm . Weight: 164g/208g
Features and benefits Range up to 8m/12m 6 mm range accuracy Easy remote operation, diagnosis and adjustment with KEY/LCD or PC Low processing power Capable 2-wire, loop powered, intrinsically safe inner temperature compensation to ensure accuracy of measurement Non-contact measurement Easy mounting via 1¿÷ NPT Low cost Application Continuous, non-contact level measurement in fluids, pastes, sullies and coarse bulk materials Characteristics Measuring Range Solids applications: 4m/6m (transducer dependent) Liquid applications: 8m/10m (transducer dependent) Measuring Resolution 2mm Accuracy 0.25% of range or 6mm, whichever is greater Max. Pulse Frequency 43.5KHz Operating Temperature -20..+80í+ Operating Pressure 0.7..3 mbar Power Supply 15..30V Power Consumption 51 mW ... 800 mW PCB Size Driver board(Ñ+:84mm), Main CTL board(Ñ+:80mm) PCB Material FR4 LCD Size 128*64dot Description ANL-4012 Ultrasonic Level Measurement Instruments use sound waves to determine level. A piezoelectric crystal inside the transducer mounted on top of the tank converts electrical pulses into sound energy that travels in the form of a wave at the established frequency and at a constant speed in a given medium. The sound waves are emitted in bursts and received back at the transducer as echoes. The Ultrasonic Level Measurement Instrument measures the time for the bursts to travel down to the reflecting surface and return. This time will be proportional to the distance from the transducer to the surface and can be used to determine the level in the tank. Ultrasonic systems are accurate within a range of approximately 8m. A typical installation consists of two parts: A Transducer, consisting of both a transmitter and receiver. Ultrasonic energy is transmitted from the í¦headí¦ in the direction of the liquid surface. When the ultrasonic waves contact the surface, they are reflected back to the receiver in the head. Electronics, which produce, control and time the ultrasonic pulses which are transmitted and received by the head. The electronics also transmit control signals to remote monitoring devices such as displays and process control systems.
Applications: *Measture the cast iron thickness,aluminum thickness,quartz glass thickness,PVC thickness,PE thickness,red copper thickness etc. Details: Case Material: Aluminum Alloy Operating Principle: Ultrasonic Measuring Range (metric / Imperial):0.75~400 mm ( 45 # steel, Depend on Probe ) Sound Velocity: 500~9,990 m/s Resolution:0.01 mm / 0.1 mm Accuracy: � (0.5%n + 0.05) For more details,please do not hesitate to contact us.Thank you!
Open Channel Flow Meters
flow meter
Weight Measurement Function: By Hours, minutes and seconds unit, Display the status of the usage of liquid gas and it can be used being installed on storage tank or tank lorry and can be carried as a portable measuring instrument. PC Monitoring Function: As the remained liquid goes below 10% of its capacity, it automatically alarms to supplement liquid gas. Thus, the appropriate time for supplement of liquid gas can be decided on time. Alarm Function: the liquid remaining of the storage tank is less than 10%, The alarm sound provides information that you can setting the a liquid supply time. Diversity Of Power Supply: Use the usual 220volt electric, in case of power outage, the built-in battery will supply the charged electricity, in addition built-in battery is operated and available for tank lorry using the car battery. Option (Printer : additional purchase): Receipt Output Function; Portable thermal transfer printer can use the output value measuring of storage tank and tank lorry without visiting a long measuring place directly by the output as a receipt.
Sound level meter Sound level meter series Application :used to test the sound level of environment , mechanic, vehicle, ship and other noise .Fit for industry , enviromental protecting , working , sanitation, teaching research and other departments. Tr-5868p / tr-5858/tr-5866/tr-5826 Standard :gb/t3785, iec651 type2, ansis1.4type 2 . Measuring range : Lp : A : 30-130db / l:35-100db h:80-130db C ; 35-130db Line:40-130db / 35-130db Ln:0-100% Dc output : 10mv=1db resolution: 0.1db. Accuracy:1db.Lcd display, Power supply :4*1.5vaaa battery / 1*9v6f22 battery /4*1.5vaa battery Dimensions : 236*63*26mm / 195*72*31mm / 233*68*32mm Weight(not including battery) 170g/195g/158g/175g
1.Better than 1% accuracy 2. 0.2% of repeatability 3. 4¡á16 english letters lcd display 4. Operate with clamp on transducers 5 rs 232 interface or 1-channel isolated oct output 6. Pipe diameters from 15mm to 6000mm 7. Ni-mh battery operation of over 12 h 8.90~230vac power supply 9. Internal data logger 10. Bilingual interface in chinese and englis. 1setone carton