Pipe fittings are the general names of parts and components that play the role of connection, control, direction change, diversion, sealing and support in the pipeline system. Steel fittings are pressure fittings. According to the different processing technology, it is divided into four categories, namely, butt welding pipe fittings (divided into weld and no weld), socket welding and threaded pipe fittings, flange pipe fittings. According to the application: 1. pipe fittings for connecting pipes are: flanges, live joints, pipe hoops, clamps, clamps, throat hoops, etc. 2. changing the direction of the pipe: bends, bends. 3. pipe fittings changing pipe diameter: variable diameter (different diameter pipe), different diameter elbow, branch pipe table, reinforcing pipe. 4. pipe fittings with additional piping branches: three links, four links. 5. pipe fittings for pipe sealing: gasket, raw material belt, thread hemp, flange blind plate, pipe plug, blind plate, head, welding plug. 6. pipe fittings for pipe fixing: clasp, hook, ring, bracket, bracket, pipe clamp, etc. According to the connection :1, welded pipe fittings 2, threaded pipe fittings 3, clamping pipe fittings 4, clamping pipe fittings 5, socket pipe fittings 6, rubber ring connection pipe fittings According to the material divided into 1, cast steel pipe fittings 2, forged steel pipe fittings 3, alloy pipe fittings 4, stainless steel pipe fittings. Pipe fittings are widely used in municipal, petrochemical, west-to-east gas transmission, ships and nuclear power.
This is chemical setting Furan based chemical resistant mortar which is combination of Liquid and Powder, when mixed in proper proportion from workable mortar which after setting and curing give of liquid and give black highly cross linked composites. Furan When set and cured is resistant to highly corrosive acids, alkalis and to powerful organic solvents such as ketones, Aromatic and Chlorinated solvents. It has extreme resistant to Acidic & alkalis, Salts, Greases and Detergents. It resists to Organic & Inorganic acids at their boiling temperature. It is suitable against mild chlorine Gas (dry) phosphorous trichloride, pyridine at room temperature. Furan is especially useful where resistance to mixed media such as aqueous acids /alkalis and organic solvents is needed in chemical plant process and waste streams. Carbon filled Furan is used against corrosive effect of hydrofluoric acid & its salts. PREPARATION OF FURANE MORTAR : Mortar consist of Furan solution and Furan powder. The average mixing ratio necessary to obtain mortar with good working consistency is 1 part by weight Solution & 3 part by weight powder. The ratio will vary slightly depending on temperature and working conditions.Stir the liquid thoroughly before using. Place liquid in a suitable shallow mixing pan. Add powder by weight in the solution mix thoroughly and rapidly until all lumps are dispersed and the mortar is completely homogenous. Spread out the mortar in a thin layer, not more than ¾ thick, to dissipate the heat of reaction and lengthen the working life. Batch size can be varied depending upon the temperature and the speed with which the masons are working. Very large batches will become stiff quite rapidly. Make sure that all the Furan Motrar is used from the pan before another batch is mixed.When working at temperature above 40 C, very small batches not more than 2 Kgs, should be prepared. When working at temperature below 15C the liquid should be kept warm.
* PHOSCAST Phoscast : Phosphate Bonded Castables * PURPOSE customers using FBC boilers (Particularly underbed feed FBC boilers) for the protection of inbed coils against erosion potential by applying highly abrasive resistant refractory on inbed coils above fuel feed system. BACKGROUND * Two of such actions are providing special alloy studs on inbed coils and applying highly abrasive resistant refractory on the outer bottom loops of inbed Coils which are above the fuel feed nozzles. * GANESHAS has taken number of approaches to identify the key factors affecting erosion rates with an objective to enhance the life of inbed tubes as well as implementing the corrective action to reduce the erosion rates. Phosphate coatings are often used to protect steel parts against rusting and other types of corrosion * Erosion of inbed coils in fluid bed combustor is unavoidable phenomenon however the rate of metal wastage and thus the life of tubes depends on various factors like ash & fuel properties, design of Combustor / feeding system, flue gas velocities operating conditions etc. It has been also observed that maximum erosion prone inbed coils are those which come above fuel feed nozzles and an area of approximately 1 to 1.5 mts around fuel feed systems are badly affected. APPLICATION Phoscast-90 XR can be applied by ramming with wooden mallet having adequately large head @" dia x 5" length x 10â?? Jong handle). The desired lining or repair thickness is built up in several courses while ramming the mass to uniform thickness. Phoscast refractory should never be trawled to obtain smooth surface; ramming only should finish surface. Any excess mass is to be sliced off with trowel edge and then finished by ramming again for bed coil. Tube application of AFBC boiler, the material pasty mass should be finger pressed into the studs of the tube with maximum force. Finish should be given by pressing the hand palm against material applied, using surgical type thin rubber hand gloves.
APPLICATION OF SK-HB K-SILICATE MORTAR : * K-SILICATE is used for jointing Acid Resisting brick in construction of vessels in suited for construction of fume chambers and stacks handling hot, dry Acid fumes and vapors. It is also used for jointing chemical resisting stoneware pipes. K-SILICATE cement is good bedding material for Acid â?? Resisting bricks and tiles. The concrete surface needed protection should be dryed, clean and rough. The bricks or tiles will be set with K-SILICATE cement over concrete surface applied with a suitable an impermeable interliner. When Bedding and Jointing Materials are the same. On the treated surface bricks or tiles are bedded to a thickness of about 6 mm and tamp gently with a wooden piece till the paste squeezes out of joints. The paste that is squeezed out of the joint should be removed by trowel with good finishing. After the mortar of the joint is dryed treat the joints with 20% Hydrochloric Acid Solution by means of brush. A.R.lining should be always in contact with Acid and not with water. Concrete subtract like Floor, Wall, tanks and similar surface should be protected with a membrane of Bitrok Mastic or compound steel tanks should be protected with rubber or PVC subjected to chemical conditions and temperature of chemical media. The Brick lining is recommended over the protective layer of Bitrok Mastic. When Bedding and Jointing Materials are Different. Spread the silicate type mortar about 6 to 8 mm thick on the back of the tile or brick. Press the tile on the bed leaving required space for joints between tiles for bricks. After the bedding mortar is set, fill Mp the joints with specified cement.PRODUCT DATA SHEET FOR SK-HB ( K-SILICATE) MORTAR A general purpose cement for acid conditions Resistant to High & medium concentrations of most of the common organic and inorganic acids except Hydroflouric acid. Recommended where the concentration of the acid is high suitable for high temperature. Unsuited to aqueous solutions, alkaline conditions. PREPARATIONS OF MORTAR : * Measure 1 part by weight of K-SILICATE solution into a suitable mixing pan. * Add slowly and gradually 3 parts by weight K-SILICATE mortar and mix thoroughly to form a smooth mortar. * In hot season very large batches of mortar will become stiff quite rapidly therefore small batches, not exceeding 4 to 8 kgs. Will be prepared. * The cement mortar will be used before it starts setting.
R-123 Refrigerant (Hydrochlorofluorocarbon) Overview: R-123 was specifically developed as a replacement for R-11 in low-pressure centrifugal chillers. It is widely used in modern systems engineered with the correct materials and sizes to meet specific cooling needs. However, retrofitting existing R-11 chillers to R-123 may require replacing certain components like seals, gaskets, and other system parts to ensure proper operation and avoid leaks. Key Features: ASHRAE Safety Rating: R-123 has an ASHRAE rating of B1, meaning it has low toxicity but requires more stringent safety measures. Lower personal exposure levels are allowed during normal daily operation, but machinery rooms must follow specific requirements as per ASHRAE Standard 15 (Safety Code for Mechanical Refrigeration). Retrofitting Considerations: When converting from R-11 to R-123, modifications may be necessary, including the replacement of gaskets and seals to achieve optimal operational conditions and leak prevention. Low-Pressure Performance: R-123 is optimized for low-pressure centrifugal chiller systems, providing efficient cooling and performance in large industrial and commercial applications. Safety Requirements: Personal Exposure: Extra precautions must be taken due to the B1 rating, which permits lower exposure levels during service and daily operation. EPA Certification: An EPA certification card is required to purchase R-123 or any other CFC and HCFC refrigerants, in compliance with environmental safety regulations. Applications: Low-Pressure Centrifugal Chillers: R-123 is primarily used in large industrial and commercial systems, providing efficient cooling in these specialized environments. Retrofitting R-11 Chillers: It serves as an effective replacement for R-11, though retrofitting may require careful modification of existing systems.
Supplier: Hot rolled steel sheet,430 stainless steel coil,301 stainless steel,304 stainless steel strip,steel strip,steel banding,steel coils,stainless steel,steel pipe,steel tube, seamless steel pipe, welded steel pipe/tube,stainless steel pipe,glavanized steel wire,galvanized steel coil,galvanized steel sheet,roofing sheet,corrugated steel sheet,gas spring tubes,precision steel tube and fabricating metals,rolling springs,shutter springs,shutt door components,spring box,bia stable steel spring coil,65mn/c75 /sk5 steel strip
Name Bluing steel strap Painting steel strap Primary color Galvanized steel strap Color blue black, blue, green, coffee color, grey primary, white galvanize Surface finish blue & oiled painted & waxed primary & oiled galvanized Material Q195 / Q235 / Q345B / DB460 / high tensile steel Elongation 3-6% / 6-8% / 8-12% Tensile strength 600-700Mpa / 700-780Mpa / 780-880Mpa / 880-980Mpa Enwind type Ribbon / Oscillated Width 9.5-50mm (Width tolerance: 0.1mm) Thickness 0.27-2.5mm (Thickness tolerance: 0.02mm)
Supplier: Fertilizer, bitumen, sesame seeds, sugar, charcoal, cashew nuts, and cement
Services: Oil and gas, customs brokerage, freight forwarding, logistics, and mining
Buyer: Fertilizer, bitumen, sesame seeds, sugar, charcoal, cashew nuts, cement
Supplier: We are importers and exporters of
1) recycle paper and tyre, paper product duplex, occ and ncc, ceramic tiles & sanitary wares, plastic recycle product ldpe.
2) industrial items : all kind of tarpaulin, pp corrugated sheets, ptfe lined pipes , fitting flanges , bar cutting and bending machineries, wood processing machineries,
3) oil & gas industries: all mech items pipes/ fittings // flangs and mech packages
4) soda ash, bicarb, free flowing edible and industrial salts etc
5) fmcg, atop, namkeens, foodstuff, pulses, grains, spices & besan, sarabati fresh chakki atta & maida. etc
Services: Import export trading