ADVANTAGE 1. Precise: The most advanced CE Cleared multi-frequency(25HZ, 50HZ, 100HZ) bioelectrical impedance body composition analyzer; 2. Expert: Totally 26 values of body composition analysis with height measurement; 3. Quick: Provides highly accurate whole body in under 20 seconds; 4. Two Printers: Inbuilt micro thermal printer and HP Color printer included at no charge. The thermal printer works speedily and conveniently and offers optional A4 size color printout; 5. Save and Output: SD card can transfer the test data to computer, and with the first letter of the customer' s name will find the test data easily.
Professional Iriscope for PC Standard Component 1. Main body (DC/IN electrical source commutator , Joint for USB line ) ,Iris lens dustproof- box 2.handset ( fuzzy ---3 second auto controller ) Japanese CCD 3.Iris lens 30X 4.USB lines 5.Instruction Warranty (Chinese edition) 6.Portable mini-aluminum box 7. A set of Iris analysis program 8.iris lens lid Accessory (sold saperately) 1.Professional Skin lens 50X 2. Professional hair lens 200X 3. Upgrade automatic analysis software Function 1.adjust brightness automatically , delete the photos ,adjust the focus ,quick fixed photos with white balance .high stability of color. Connect with computer directly without outside power and easy to operate. 2. the software can save and correct the client information and details of products ,after take photos ,you can analysis the iris picture and compare the picture .can print the analysis report ( adjust the focus to 1-3X ) ,save the photos according to the time you take photos 3..add hair lens ,see the injured hair , hair character , dander and scalp bacterium 4.Upgrade the copyright according clients need . This machine will help the client know his health condition frankly ,including the problem which you have get in the former ,now and future .and the Iridology will be your health counselor, tell you how to keep away from the illness and sub-health. Accessories : a basic iridology book .one piece of iris studying VCD ,iris chart ,12 basic iris symptom chart The postfix of our Item No "A" means this Iriscope can be used with TV and you can capture the iris picture use the capture key which on the top of the handset. and before use this to capture iris picture you should plug in the electric with the transformer ,after you capture the iris picture on the screen of the then according to the marks on the iris picture to explain the health condition of the clients .as we know TV cannot memory the iris pictures. "U" means this Item connect with the computer through the USB port ,and we provide our software with it , and you can use the software to help you save the iris picture , clients information and to analysis the iris , it doesn't need the outside power , this one is more suitable for the one who have a computer and want to check the client. "AU" means it can be used either on TV or computer and also can be connected with TV & PC at the same time. it include the function of "A" & "U" net weight :2.6kg Spec : 33x28.5x11.5 cm Portable Aluminum Box
YJ-8501 Anesthesia Machine is equipped with an accurate dedicated anesthetic vaporizer and a safety device for preventing cyanosis and a necessary alarm system. During the anesthesia, the patient's respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient. Pneumatically driven and electrically controlled system Built-in ventilator, 8.4 LCD display screen Closed; Semi-Closed; Semi-Open working mode Applied for Adult and Pediatric
ZXE-E Type Automatic Cardiovascular Function Diagnostic Meter (1) Integrated Design Automatic Cardiovascular Function Diagnostic Meter is based on the principle of pulse pressure according to the theory of the model sub-room network analysis about elastic chamber model of human circulatory system and the formula derived by a linear correlation algorithm. These formulas will be able to reflect cardiac function, vascular status, blood status and microcirculation function in 35 cardiovascular function parameters and the 64 pieces of professional aided diagnostic information through the non-linear compensation and parameter modification from clinical experience. Automatic Cardiovascular Function Diagnostic Meter is a latest diagnostic equipment in the market with its feature "portable integration" model, and a total weight 3Kg, size 420 í- 260 í- 130 (slant) mm. The panel of the Analyzer is embedded 7 "blue backlit LCD screen and touch buttons; the front of the ramp is embedded high-speed thermal printer to provide menu and print the report in Chinese. If the products is for export, we can change the menu in other languages. Automatic Cardiovascular Function Diagnostic Meter (integrated design) is light and portable, simple to operate, with reliable quality, elegant style, and low prices, which is very popular with customers. It is especially suitable for volunteer team activities to promote medicine and health products. The integrated design is one of the best-selling model at present. It has truly professional and portable integrated design. The system consists of dedicated computer, bright liquid crystal display modules, special micro-thermal, printers, and pulse sensors . With auto-detection of 35 cardiovascular function parameters, and 64 pieces of exported diagnostic information, the Automatic Cardiovascular Function Diagnostic Meter can automatically print diagnostic report. Size: 37X33X14cm3. Weight: 3kg.
Supplier: Chemical composition, physical performance analysis, testing instruments and equipment suppliers and service providers. the products series are:lab equipment, icu equipment, medical imaging equipment , cold chain medical deep freezer.
Services:
Place of Origin: China Brand Name: OEM Model Number: BP68302 Type: Pathological Analysis Equipments Size: 13cmx2.3cm Net weight: 15g/set Material: ABS Printing: Silk screen printing Contents: 5pcs spare Monofilaments
Place of Origin: China Brand Name: OEM Model Number: ECG1200G Power Source: Electric Warranty: 1 Year After-sale Service: Repair and Replacement Power Supply Mode: Built-in Battery Material: Plastic Shelf Life: 1years Quality Certification: ce Instrument classification: Class II Safety standard: None Type: Pathological Analysis Equipments Product name: 12 Channel ECG Machine Certificate: CE ISO Display: LCD Display Dimension: 340mm(L) * 320mm(W) * 85mm(H) Weigh: 3.2Kg Power supply: AC/DC AC: 100V~240V(50/60Hz) DC: 14.8V/3500mAh rechargeable lithium battery Paper size: 210mm(W)*20m(L)
KMNPack's Biological indicators are a special type of living microbial products that can be used to confirm the performance of sterilization equipment, the verification of sterilization procedures, and the monitoring of sterilization effects in production processes. It is defined as a defined resistance to a specific sterilization process and is available in the inner packaging for the carrier KMNPack Biological Indicator Rapid Reader adopts spectrum analysis technology to monitor the fluorescence changes of the Bacillus Stearothermophilus with special enzyme to rapidly judge whether there is surviving spores.The Reader is compatible with most popular rapid readout biological indicators in the market and can be used to validate the sterilization efficacy of sterilizers.The Rapid Reader is able to make judgments within 20~180 minutes to ensure implantation operations can be carriedout in time,and in the meantime,a report can be printed for traceability.
Product description Partial discharge comprehensive analyzer is the dedicated product to measure and analyze the insulation ability of electrical equipment. This system adopts modern electronic and computer integrated technology with the functions of signal amplification(analog signal, electronic signal, digital signal), filtration, data sampling, data processing, figure display, test report generation automatically so that it may finish the measurement, location and analysis of the partial discharge. Technical index Technical characteristics Number of interfaces Free-running 4 interfaces Sampling rate 1M. 5M. 10M selected Sampling accuracy 12bit Range changing -40dB, -20dB, 0dB, 20dB, 40dB ,60dB, totally 6 types Measurement frequency range 3db bandwidth 10kHz 1MHz Digital filtering 10kHz 1MHz freely selected Program controlled filter subsection Nonlinear error in the range 10% Measurement range 0.1pC~100,000pC Sensibility 0.1pC Capacity range of the measured product 6pF 250 F Frequency range of test power 50 500Hz Display Display screen 12 TFT true color touchable LCD screen Resolution 1024 768 Interface USB 3 types, use of external mouse, keyboard or other USB devices. Power mode AC 220V; Frequency 50Hz; Power 300W Electric signal interface 4 BNC interfaces, use of signal input. Optical signal interface 4 types, use of signal input Network interface 1 type Landing button External landing General instruction CPU Basic frequency 1.60GHz Ram 2.0GB Hard disk 128GB SSD System Windows Xp Operating environment Size Weight 15.8kg