One-Step Troponin I /CK-MB/ Myoglobin Rapid Test is intended for the qualitative determination of cardiac disease in human serum, plasma or whole blood.
Product Details:
Brand : Boditech Med Incorporated
Size : 25 T
Samples : Human whole blood/ serum/ plasma/control
Specimen volume : 10 Microliter
stored at 4 - 30 DegreeC
Cat No : CFPC-77
NT-proBNP
Helping to diagnose heart diseases and evaluate the severity level
BNP and NTproBNP are peptides that are continuously produced in the heart. When the muscles in the left ventricle over-stretch as in heart failure, the secretion of these peptides into blood increases. One may utilize the level of NTproBNP in blood to assess the cardiac event and its severity. Both of BNP and NTproBNP can be used to show different aspects of the heart failure.
INTENDED USE:
ichroma NT-proBNP is a fluorescence Immunoassay (FIA) for the quantitative determination of NT-proBNP in human whole blood/serum/plasma. It is useful as an aid in the diagnosis of persons suspected of having congestive heart failure.
For in vitro diagnostic use only.
PRINCIPLE :
The test uses a sandwich immunodetection method; the detector antibodies in buffer bind to antigens in the sample, forming antigen-antibody complexes, and migrate onto the nitrocellulose matrix to be captured by the other immobilized-antibodies on test strip.
More antigens in the sample will form more antigen-antibody complexes which lead to stronger fluorescence signal by detector antibodies, which is processed by instrument for ichromaâ?¢ tests to show NT-proBNP concentration in the sample.
The One Step Test for NT-proBNP (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine NT-proBNP in human serum, plasma, or whole blood specimens. One monoclonal antibody and one polyclonal antibody are employed to identify NT-proBNP specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of NT-proBNP.
Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of NT-proBNP is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The cardiac troponin i fast test kit (colloidal gold) is intended for use together with the fia8000 quantitative immunoassay analyzer (fia8000). The product employs colloidal gold immunochromatogrphy to determine ctni in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify ctni specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of ctni.
Then insert test card into the fia8000 quantitative immunoassay analyzer, the concentration of ctni is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for PCT (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine PCT in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify PCT specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of PCT.
Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of PCT is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for NAGL (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine NGAL in human urine specimen. Monoclonal antibody and polyclonal antibody are employed to identify NGAL specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of NGAL.
Then insert test card into the FIA8000 Quantitative Immunoassay Analyzer, the concentration of NGAL is measured quantitatively and displayed on the screen. The result can be transmitted to the lab or hospital information system.
The One Step Test for B2-MG (colloidal gold) is intended for use together with the FIA8000 Quantitative Immunoassay Analyzer (FIA8000). The product employs colloidal gold immunochromatogrphy to determine B2-MG in human serum, plasma, or whole blood specimens. Two monoclonal antibodies are employed to identify B2-MG specifically, resulting in a purplish red streak appears on the test line. The color intensity of the test line increases in proportion to the concentrations of B2-MG.