Application: CNG, LPG, LNG, AIR Body Material: Aluminium Pressure (absolute): 0~400kPa Accuracy:1% for pres. & temp. Thermal compensation:Yes Pressure response time: 1ms Temperature sensor:NTC 10KΩ (B25/50=3950) Temperature response time:2s Working Temp: -40~120 Socket Thread: M12x1.25 (defalt), M12x1 Connector type: C4 Mate Connector: AMP 1-967640-1 Burst Pressure:1600kPa Protection: IP67
PCFS-IR2125A level sensor contact type, it is used for tube. The principle is infrared, output signal is analog. When there is no water, the sensor outputs low voltage value; When there is water, the sensor outputs a high voltage signal. The size can be customized. The photoelectric liquid level switch has high precision, low price, high reliability and wide application environment, it is less affected by strong acid, alkali and viscosity. Photoelectric level sensors can be used for higher liquid level accuracy requirements.
Application: Siren and alarms is widely used in fire fighting, car, office, residential building and security equipment etc Specifications: Dc resistance: 19 ohm +/- 10% Impedance: 100 ohm +/- 25% at 1khz Frequency range: 2000hz +/- 20% S.P.L: >= 90db at 10cm 2000hz 9vp-p square wave >= 95db at 30cm 1000hz 12vp-p square wave Export standard carton
Agecho ultrasonic sensors salient features: Agecho ultrasonic sensors are available with output options such as analog current 4-20ma analogue voltage 0-5v on/off signal trigger output for multi-sensor application pulse width serial ttl serial rs 232c. Agecho is very useful non-contact type of sensing or presence or counting of object. On/off type signal is also available. Agecho sensing range: 200mm to 1000mm … up to … 6000mm. (19.7feet) (0-200mm is dead band). Agecho accuracy is 1% of the full scale. Agecho operating voltage 12v dc with reverse polarity protection.(24v dc optional) Agecho is self-calibrated. Microcontroller is present in each sensor. This provides direct distance/depth reading with better calibration and communication with the controller module. Agecho is very easy to install rugged design for use in dusty and humid conditions suitable for outdoor as well as indoor use. Agecho very useful for non-contact distance/level measurement. The distance of the target is measured not just its presence but gives directly 4-20ma serial or pulse width data proportional to the distance of the target. Agecho operating temperature 0 to 65 degree celsius. Agecho temperature compensated measurement for better accuracy (optional). Agecho unaffected by ambient light object color or any other optical characteristic. Works with hard materials like metal sheet plywood or soft materials like cloth and paper rubber etc.
Professional; improving; cooperation; win-win: these are our philosophy. We believe quality is the life of company and honesty is the basic rule of market. We will try our best to offer satisfying service. And welcome your cooperation. All size you want
Cylindrical close to switch Lj series 1 Lj series 2 Pr series E2e series Close to switch models and meaning
OUTPUT : 4-20 MA SUPPLY : 24 VDC TYPE :2 WIRE PRESSURE TRANSMITTER CAPSULE TYPE PROTECTION CLASS : IP 65 PROCESS CONNECTION : 1/2 " BSP;1/2"NPT ;1/4"BSP;1/4"NPT FIXED RANGE CAPSULE TYPE
Performance Sensitivity na/ppm at 2ppm co 420 to 650 Response time t90 (s) from zero to 10ppm co < 25 Zero current na in zero air at 20°c +30 to -130 Noise* ±2 standard deviations (ppb equivalent) 4 Range ppm limit of performance warranty 1000 Linearity ppb co error at full scale, linear at zero, 500ppm co 20 to 35 Overgas limit maximum ppm for stable response to gas pulse 2000 * tested with alphasense isb low noise circuit Environmental Sensitivity @ -20°c (% output @ -20°c/output @ 20°c) @ 5ppm co 40 to 70 Sensitivity @ 50°c (% output @ 50°c/output @ 20°c) @ 5ppm co 110 to 125 Zero @ -20°c na -30 to +30 Zero @ 50°c na -50 to -200 Cross sensitivity Filter capacity ppm·hrs h2s 250, 000 H2s sensitivity % measured gas @ 5ppm h2s < 1 No2 sensitivity % measured gas @ 5ppm no2 < 1 Cl2 sensitivity % measured gas @ 5ppm cl2 < 1 No sensitivity % measured gas @ 5ppm no < -3 So2 sensitivity % measured gas @ 5ppm so2 < 0.1 H2 sensitivity % measured gas @ 100ppm h2 at 20oc < 10 C2h4 sensitivity % measured gas @ 100ppm c2h4 < 1 Nh3 sensitivity % measured gas @ 20ppm nh3 < 0.1 Key temperature range °c -30 to 50 Specifications Pressure range kpa 80 to 120 Humidity range % rh continuous 15 to 90 Storage period months @ 3 to 20°c (stored in sealed pot) 6 Load resistor o (isb circuit is recommended) 33 to 100 Weight g < 13 Isweek provide smoke, gas, humidity&temperature, uv, fluid or other kinds of sensors More details welcome to inquiry: skype:isweek_laura
Optical, Ultrasonic, Conductive, Fibre, Float, Inductive, Magnetic, Capacitive, Laser, Loop Detectors, HMD, Light Curtain, Sensor Inductive Sensor / Capacitive Sensor Proximity Sensor, Photoelectric Sensor, Level Sensor, Ultrasonic Sensor, Wind Sensor, Motion Sensor, Magnetic and Light Curtains, etc