1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Clenbuterol in the pork. The coupling antigen is pre-coated on the micro-well stripes. The Clenbuterol in the testing sample competes with the coupling antigens pre-coated on the micro-well stripes for the antibodies against Clenbuterol. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the testing sample has a negative correlation with the content of Clenbuterol in it. This value is compared to the standard curve and the content of the corresponding Clenbuterol is subsequently obtained.

2. Technical specifications
Sensitivity : 0.1 ppb
Detection limit:
Tissue0.1ppb
Urine, serum0.1ppb
Feed50 ppb
Recovery rate
Urine, serum9010%
Tissue8010%
Feed8015%
Cross-reaction rate:
Clenbuterol100%
Terbutalin< 1%
Salbutamal< 19%
Ractopamine< 1%



96 well
Oct-24-07
 
1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Florfenicol in the tissue (chicken,pork), fish, shrimp , honey. The coupling antigen is pre-coated on the micro-well stripes. The Florfenicol in the testing sample competes with the coupling antigen pre-coated on the micro-well stripes for the antibody against Florfenicol. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the testing sample has a negative correlation with the content of Florfenicol in it. This value is compared to the standard curve and the content of the corresponding Florfenicol is subsequently obtained.

2. Technical specifications
Sensitivity : 0.5ppb
Detection limit:
Honey1.5ppb
Meat,liver,shrimp ,fish0.5ppb
Recovery rate
Honey70%10%
Meat,liver,shrimp ,fish80%10%
Cross-reaction rate:
Florfenicol100%
Thiamphenicol¼T0.1%
Chloramphenicol¼T0.1%



96 wells
Apr-12-10
 
Tetracycline residue rapid test device.






40 pcs/kit.
May-16-24
Supplier From Ahmedabad, Gujarat, India
Jan-09-18
Buyer From Mumbai, Maharashtra, India
Sep-29-15
Supplier From Bangkok, Chatuchak, Thailand
Feb-05-23
Supplier From India
Sep-13-13
Supplier From Jiaxing, Zhejiang, China
Jul-14-14
Supplier From Shanghai, China

Verification Status