Siemens, merlin gerin, abb, westinghouse, honeywell, ge, schneider, allen bradley, moeller, aeg, fuji, furnas, albright, lovato, benshaw, hager, l&t, brook, chint, danfoss, omron, teco, sprecher, stromberg, togami, joslyn clark, eaton, matsushita. Specific contactors, low voltage contactor, magnetic contactors, solid-state contactor, definite purpose contactors, modular contactor, low noise contactor, miniature contactor, standard contactor, contactors for special applications
TeSys D contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). It provides a 220V 50/60Hz AC coil and 1NO+1NC built-in auxiliary contacts. Multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)
1. GMC electrical magnetic ac contactor is suitable for using in the circuits up to the rated voltage 660V AC 50HZ or 60HZ, rated current up to 95A, for making frequently starting & controlling the AC motor. 2. 09-220A GMC AC Contactor can be Combined with the auxiliary contact block, thermal relay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. 3. With the thermal relay, it is combined into the electromagnetic starter.
CJX7/A Types 3 Phase Electrical Contactor is mainly used in power system with AC 50Hz(or 60Hz), the rated working voltage up to 660V, under the application category of AC-3, when the rated working voltage 380V, the rated operating current to 300A electrical, for the long-distance range making and breaking the electric circuit, and combines the electromagnetism starter with the suitable thermal overload relay or the electronic protector to protect against the possible overload electric circuit during operation(running).
CJ19 electrical Switch-over Capacitor Contactor is mainly applicable to a power line of AC 50Hz or 60Hz, rated working voltage up to 380V. It is used to put a low voltage parallel connected capacitor in operation or switch it off in a low voltage reactive power compensation device. The contactor is equipped with a surge suppressor, which can effectively reduce the surge current passing through the capacitor at switching on and suppress the over-voltage at switching off.The product is in conformity with the standards IEC947-4-1.
LP1-D series DC operated AC contactor is suitable for use in the circuits up to rated voltage 660V AC 50Hz or 60Hz,and in rated current 9-95A in AC-3/380V load circuits It for remote controlling circuit making,breaking and frequent starting AC motors It can also combine with the auxiliary contact group,air delayer,thermal relay devices etc
Overview The AF Series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available UA16-30-10 RA UA26-30-10 AF9-30-10 AF1250-30-11 UA16-30-10 RA UA26-30-10 AF12-30-10 AF1350-30-11 UA16-30-10 RA UA26-30-10 AF16-30-10 AF1650-30-11 UA16-30-10 RA UA26-30-10 AF26-30-11 AF2050-30-11 UA26-30-10 RA UA30-30-10 AF30-30-11 AF2650-30-11 UA26-30-10 RA UA30-30-10 AF40-30-11 A9-30-11 UA26-30-10 RA UA30-30-10 AF50-30-11 A12-30-11 UA26-30-10 RA UA30-30-10 AF63-30-11 A16-30-11 UA30-30-10 RA UA50-30-00 AF75-30-11 A26-30-11 UA30-30-10 RA UA50-30-00 AF95-30-11 A30-30-11 UA30-30-10 RA UA50-30-00 AF110-30-11 A40-30-11 UA30-30-10 RA UA50-30-00 AF116-30-11 A50-30-11 UA50-30-00 RA UA63-30-00 AF140-30-11 A63-30-11 UA50-30-00 RA UA63-30-00 AF145-30-11 A75-30-11 UA50-30-00 RA UA63-30-00 AF146-30-11 A95-30-11 UA50-30-00 RA UA63-30-00 AF185-30-11 A110-30-11 UA63-30-00 RA UA75-30-00 AF205-30-11 A145-30-11 UA63-30-00 RA UA75-30-00 AF210-30-11 A185-30-11 UA63-30-00 RA UA75-30-00 AF260-30-11 A210-30-11 UA63-30-00 RA UA75-30-00 AF265-30-11 A260-30-11 UA75-30-00 RA UA95-30-11 AF300-30-11 A300-30-11 UA75-30-00 RA UA95-30-11 AF305-30-11 A320-30-11 UA75-30-00 RA UA95-30-11 AF370-30-11 AF460-30-11 UA75-30-00 RA UA95-30-11 AF400-30-11 AF580-30-11 UA110-30-11 UA110-30-11 UA110-30-11 AF750-30-11 UA110-30-11 UA110-30-11 UA110-30-11
Power Contactor Range Rating: 9A~200A Poles: 3Pole & 4Pole Available Brands : Scheneider, Siemens, ABB, Larsen & Toubro, Eaton, C&S, Legrand, Havells, BCH
GSC1 series AC Contactors are used in the circuit of 50Hz or 60Hz frequency with rated current up to 95A under usage category AC-3 at 380V AC. These AC contactors comply with IEC60947-4: Rated Isolation Voltage: up to AC690V Rated Voltage: 220V AC or 380V AC or 415V AC or 440V AC or 660V AC Rated Current under usage category AC-3 at 380V AC (A) : 9A, 12A, 18A, 25A, 32A, 38A, 40A, 50A, 65A, 80A, 95A Rated Thermal Current (A): 25, 25, 32, 40, 50, 50, 60, 80, 80, 125, 125 Controlled Load Power at 380V AC (KW): 4, 5.5, 7.5, 11, 15, 18.5, 18.5, 22, 30, 37, 45 Electrical Life (104) under usage category AC-3: from 60 to 100 Operation Frequency under usage category AC-3 (times per hour): from 300 to 1000 Mechanical Life (104): from 600 to 1000 Contact number: 3P+NO or 3P+NC, 3P+NO+NC if Rated current being over 38A. Frequency: 50Hz or 60Hz Coil Voltage: AC24V or AC48V or AC110V or AC220V or AC380V. Contact: 90% Silver and 10% Ni or 88% Sliver and 12% Cadmium Oxide.