V-cell air filter widely use for medium filtration in industry and commercial field. That is medium filter in clean room hvac system. Characteristics: 1: the v-cell air filter use for filter more than 0.5um particles and dust in hvac air conditional system , that particular design for hvac project at low resistance with big air volume. 2: the filter media adopt the pp media or ultra-thin glass fiber with high dust holding capacity , the hot-melt glue spacing each pleats in regular so that achieve high dust volume , all of the media area can be used in completely . 3: the polypropylene plastic frame can be incineration when use out . 4: the filter with flange can replace by pocket air filter. The sealant around the media so that the air filter without any air leaking 5: the v-cell air filter efficiency range: f6, f7, f8, f9(en779). Dimension and parameter: Dimension (w*h*d) (mm) Pack Air flow (m3/h) Media area (m2) Holding dust(g) Primary resistance (by0.5m/s) Final Resistance Efficiency (0.3um) 287x287x292 2 900 4.63 280 ¡´60 250-300 F6 ¡´80 300-400 F7 ¡´100 300-400 F8 ¡´120 400-450 F9 592x592x292 3 2850 15 900 ¡´60 250-300 F6 ¡´80 300-400 F7 ¡´100 300-400 F8 ¡´120 400-450 F9 592x592x292 4 3800 20 1200 ¡´60 250-300 F6 ¡´80 300-400 F7 ¡´100 300-400 F8 ¡´120 400-450 F9 592x490x292 4 3100 16.44 1000 ¡´60 250-300 F6 ¡´80 300-400 F7 ¡´100 300-400 F8 ¡´120 400-450 F9 592x287x292 4 1750 9£®26 550 ¡´60 250-300 F6 ¡´80 300-400 F7 ¡´100 300-400 F8 ¡´120 400-450 F9 Customized size is available .
High purification rank, low resistance, super-thin and light weight, easy install and low operated cost . Mini-pleats hepa filter widely use for electronic, pharmacy, food, semiconductor, Atomic force, precise instrument and cosmetics field and so on, which occasional request high purification rank. Dimension and parameter: Dimension (w*h*d) (mm)Air flow (m3/h)Media area (m2)Holding dust(g)Primary resistance (by0.5m/s)Final ResistanceEfficiency (0.3um) 305x305x502001.810099.99% H13-h14 484x484x505004.6300
A suitable solution for. Airborne substances, viruses and other fine particles in the nanoscale range are filtered out of the air with a separation efficiency of 99.995 % and the activated charcoal filter also removes odours. The integrated CO2 sensor alerts you should additional ventilation be required.
Mini-pleat construction with Al frame Glass fiber media pack EN1822 U15 and U16 grade MPPS 99.9995% ~ 99.99995%
HEPA Filter Combination HEPA filter
Air filter compressed air filter 1). Separator filter (HF9) For bulk liquid removal plus a 3 micron coalescer (5ppm w/w maximum remaining oil content) Two-stage filtration * First stage: two stainless steel orifice tubes provide 10 micron mechanical separation * Second stage: in-depth fiber media captures solid and liquid particles to 3 micron 2). Air line filter (HF7) For removal of liquid water and oil; removes solid particles to 1 micron (1.0 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two-stage filtration * Firt stage: captures larger particles with alternate layers of fiber media and media screen * Second stage: coalesces aerosols and captures solid particles with multiple layers of epoxy bonded, blended fiber media 3). High efficiency oil removal filter (HF5) For coalescing fine water and oil aerosols; removes solid particles to 0.01 micron (0.01 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * First stage: multiple layers of bonded, blended fiber media for fine coalescence * Second stage: multiple layers of bonded, blended fiber media for fine coalescence Outer coated, closed cell foam sleeve 4). Ultra high efficiency oil removal filter (HF3) For coalescing ultra-fine oil aerosols; removes solid particles to 0.01 micron (0.001 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * First stage: coated, closed cell foam sleeve acts as pre-filter and flow disperser * Second stage: multiple layers of matrix blended fiber media for ultra-fine coalescence Outer coated, closed cell foam sleeve 5). Oil vapor removal filter (HF1) For removal of oil and hydrocarbon vapors normally absorbable by activated carbon; removes solid particles to 0.01 micron (0.003 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * first stage: stabilized bed of finely divided carbon particles removes the majority of the oil vapor * Second stage: multiple layers of fiber media with bonded micro fine carbon particles remove the remaining oil vapor Multiple layers of fine media prevent particle migration Outer coated, closed cell foam sleeve prevents fiber migration Designed life is 1000 hours under rated conditions.
External frame : metal (aluminum alloy or by your requirement) Sealant : polyurethane glue separator : Hot glue Gasket : Ethylene vinyl acetate (EVA) Filter media : Glass fiber Use the highest temperature, humidity : 80, 80%. Various size according to customer require.
Without gasket size:610mm*610mm*69mm Efficiency:H13 Frame£ºAluminum Frame Media:Fiberglass Filter Paper Faceguard:Aluminum Net 635mm*635mm*100mm about 3kg