CV7-V Ultrasonic Wind Speed Sensor Description The CV7 is easily integrated into measurement and monitoring systems. The CV7-V is powered by 8-30 VDC power supply and it outputs RS232/RS422 (5V level signal) / NMEA0183. CV7-V Ultrasonic Wind Speed Sensor Application Static wind sensor A conventional wind vane/anemometer features mechanical rotating parts. These moving parts expose the sensor to failure. CV7 series was extensively tested in Marine applications for both precision and robustness. Configurable wind sensor CV7-V can be programmed and configured for : angle correction, smoothing time constant, units of measurement and interface format. CV7-V connexion CV7-V can be used connected to a PC and any systems featuring an NMEA® input port and specific pieces of equipment using conventional formats. In PC mode, this bidirectional sensor can be set up for angle correction, damping, measure units and interface format. Quality All LCJ Capteurs are designed and manufactured in the Nantes region in France where they are fully tested throughout the manufacturing process. CV7-V Ultrasonic Wind Speed Sensor Specification: Output data format: NMEA0183; MWV, XDR Information transmited: Instant. W. Speed, Instant. W. Angle, avaibility Output rate: 2 Hz / 30 Hz measurement Wind module sensitivity: 0.12 m/s Wind module resolution: 0.05 m/s Wind module dynamic: 0.12 to 40 m/s Direction sensitivity: +/-1.5 degree Direction resolution: 1 degree Power supply: 8 V to 30 V DC Electrical consumption: 9 mA Op. temp. without icing: -15 degree C to +55 degree C Cable: 25 m / 4x0.22 mm2 Connection: 4 wires Weight of the head: 100 gr Weight of unit assembly: 200 gr with mounting part Mounting: Vertical ; 300 aluminium arm, 16 mm