Model JAGUAR A6 Heating System Number of heating zones UP 6/BOTTOM6 Number of cooling zones 1 Length of heating zones 2400MM Heating mode Up:hot air; bottom: IR Cooling Mode Force air Conveyor System Max. Width of PCB 350mm Mesh belt width 400mm Transmission Direction LR(or RL) Transmission Net Height 880±20mm Transmission type Mesh Conveyor speed 0-1000mm/min Fixed rail side Front rail fixed(option:rear rail fixed) Control system Power supply 5 line 3 phase 380V 50/60Hz Total power 28kw Starting power 24kw Normal power consumption 4KW Warming time About 20 mins Temp. setting range Room temperature-300 Temp. control method PID close loop control & SSR driving Temp. control precision ±1 Temp. deviation on PCB ±2 Data storage Process Data and status storage (80 GB) Nozzle plate Aluminum Alloy Plate Abnormal Alarm Abnormal temp. (extra-high/extra-low temp.) Board dropped alarm Tower light:yellow-warming, Green-normal, Red-abnormal General Dimension(L*W*H) 35007001320mm Weight 600KG Color Computer gray