1.Special ripper process, corrugated paper has high intensity structure 2.Using the imported 100% wood puip,fine percolation and absorbing water to ensure drip wet the wall completely 3.Products involves surface active agent, absorb water naturally, fast speed of pervation, lasting effectiveness 4.Special water-proof gule and paper soaking resin, corrosive resistance and anti-mildew, double service time. 5.Spatial crossing linking technology and specific stereoscopic structure, it can provide the largest evaporative surface for the heating exchanging between water and air 6.Cooling efficiency as high as 85% 7.We offer the high quality product with competitive price 8.The cooling pad can be customized Specification Height:1500mm/1800mm/2000mm width:600mm Thickness:100mm/150mm/200mm "Wet curtain - fan" of the vertical ventilation cooling combination is the most economical and effective measures to cool the greenhouse in summer. Years from the application of a real show, even in the heat of the day reported, the rational design and installation of a fan of wet curtain cooling system can still control the greenhouse temperature at 30 ¡ãC, in order to heat the greenhouse to reduce the adverse effects minimum.In the summer, your production needs Jienuo wet curtain to help. RDER the principle of wet curtain cooling RDER wet curtain cooling system of the cooling process is in the base core ¡§C RDER paper pad completed. Fiber in corrugated paper thin surface layer of water film, when the outdoor air is dry and hot fan suction pad through the paper, the water film on the water will absorb heat from the air and then evaporating the water vapor, so that after treatment The cool, moist air to enter the interior of the. This natural process as if the wind across the water. The external environment, the air dry bulb temperature and wet bulb temperature at each moment is different. Dry bulb temperature and humidity bulb temperature is low, the more hot weather and the wet bulb temperature difference greater. Wet curtain can reduce the temperature depends on the temperature difference between dry and wet bulb air to listen and wet curtain time efficiency, cooling the product value is both stable operation of the cooling effect of wet curtain is usually the same. Can be seen in more hot weather, wet curtain cooling the better. Wet curtain cooling Evaporative Cooling pad design of the greenhouse Greenhouse heat source from: heat conduction, thermal radiation. Heat conduction and thermal radiation heat load depends on the weather conditions, greenhouse structures and greenhouse shade treatment. All of these lead to increased greenhouse heat and humidity should be ruled out by the wind, so suitable for indoor ventilation is a good pad - fan based cooling system. The following is the calculation of greenhouse ventilation rate often used when the rated ventilation Experience: Calculate the required ventilation rate, the pad area in determining when to consider the pad area must consider the efficiency of the wet curtain, resistance and the economy to achieve the right balance between. Pad installed the more the better the cooling effect of course, the ventilation resistance is also smaller, but the investment is higher; and vice versa. Therefore, we propose to choose the light of experience following the curtain wind speed: 100 mm thick pad :1.2-1.5 m / s. Green House Evaporative Cooling Pad