Electricity System SPD, M-GDT, MOV, Signal System SPD Feeder System SPD
Brands : Siemens, Schnieder, Abb, Legrand, Chint, Havells, L&T, C&S, HPL etc Voltage : 275, 440, 255 Breaking Capacity : 10kA,12.5 kA, 25kA, 40kA, 80kA Modules : 1,2,3,4,5,6,7,8 If you have been looking for Schneider, ABB, L&T, Siemens, Chint, havells, HPL, Hager etc SPD dealers, your search ends here as you can get the best SPD distributors in countries such as USA, UK, Australia, Sweden, Africa, Middle east, Europe, Asia etc. You can purchase SPD of the finest quality and rest assured to get the best in terms of both durability and performance
Surge protective device, spd, distribution box, floor box, junction box, weather protected box
Class B / Type I Class C / Type II Class D / Type III Data Surge Protection PoE Surge Protection Signal Surge Protection
DK-20 power supply series modular surge protective device(SPD) is designed according to IEC61643 standard. It is accordance with the criterion of Low-voltage Surge Protective Devices-Part 1: Surge Protective Devices Performance Requirements and Test Method of Low-voltage Power Distribution System. With good sealing, it is designed as module and 35mm DIN-Rail Mounting. With working indication window, temperature control circuit breaker and built-in over-current protective� circuit, the modular SPD can release automatically to avoid fire danger when it breaks down. With remote alarm connector, it is convenient for remote monitoring. The main module and the base are replaceable. The lightning protection modes is L-PE, N-PE (2P/4P) or L-N-PE (1+1) / (3+1).
Techwin DIN rail 40kA Class C surge protection deviceSPDTüV certificated for Three-phase 380V AC system APPLICATIONS: Class C Surge Protective Device for AC Power System. A. Power distribution box(cabinet) B. AC cabinet, cabinet air conditioner, C. PV inverter, Solar inverter, inverter charger, inverter cabinet D. Switching mode power supplySMPS Box, SMPS cabinet high-frequency switching mode power supply,UPS system E. Data center, IDC power system, Column head cabinet F. Charging station/charging point Sensitive electronic equipment pulse width modulation(PWM box) Automatic control panels, motor control panels IT,TT,TN-C,TN-S,TN-C-S and other power supply system. FEATURES: DIN rail mounting for easy installation Plug connectors for quick and easy connection or rewiring 40kA maximum surge current Thermal disconnect device Status indicators visually verify protection level Surge protection device with N-PE residual current spark gap as 3+1 circuit Remote alarm function ISO 90012008 certificatedISO14000:2004 certificated and OHSAS180002007 certificated High quality products with TüV, CE, UL certificate TECHNICAL PARAMETER ModelM40B3+N Electrical parameter Nominal working voltage Un 50/60Hz 220/380V, 230/440V Max. continuous operating voltage Uc385V Nominal discharge current8/20µsIn20kA Max. discharge current 8/20µsImax40kA Protection level @20kA , 8/20µs Up1500V Let through voltage @3kA , 8/20µs800V Response time tA25ns Protection modeL1/L2/L3-N, N-PE General data Dimension90 (H)Ã?72 (W)Ã?65(L)mm Weight per unit500g Mounting35mm DIN rail Recommend cross-sectional areaL/N 10mm2 PE16mm2 IP codeIP20 Working conditionsTemperature: -40 to 80, Relative humidity: 95 Test standardsIEC61643-1, UL94-V0, ROHS
DK-40 power supply series modular surge protective device(SPD) is designed according to IEC61643 standard. It is accordance with the criterion of Low-voltage Surge Protective Devices-Part 1: Surge Protective Devices Performance Requirements and Test Method of Low-voltage Power Distribution System. With good sealing, it is designed as module and 35mm din-rail mounting. With working indication window, temperature control circuit breaker and built-in over-current protective� circuit, this SPD can release automatically to avoid fire danger when it breaks down. With remote alarm connector, it is convenient for remote monitoring. The main module and the base are replaceable. The lightning protection modes is L-PE, N-PE (2P/4P) or L-N-PE (1+1P) / (3+1P).
APPLICATIONS: Techwin Industrial POE (Power over Ethernet) SPD (Surge Protection Device) is specially designed for Ethernet switches. The POE switch will not be damaged by lightning overvoltage, induced overvoltage, and electrostatic discharge. CAT5e and CAT5 compatible IEEE 802.3afï¼?803.1at 10/100 Base-T Ethernet protection LAN, FDDI, CDDI, ATM,WLAN PDH, SDH, SPDH Industrial control Industrial POE, With High reliability and high stability Surge protection for power supply system, SPD for low-voltage installations and device.CCTV system.
FEATURES: DIN rail mounting for easy installation Plug connectors for quick and easy connection or rewiring 25kA Iimp capability Thermal disconnect device Status indicators visually verify protection level Surge protection device with N-PE residual current spark gap as 3+1 circuit Remote alarm function ISO 9001ï¼?2008 certificatedï¼?ISO14000:2004 certificated and OHSAS18000ï¼?2007 certificated High quality products with CE, Rohs certificates
Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure. Surge Protection Device (SPD) It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component. SPD for Power Supply System Series Selection Guide The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity. The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose. SPD for power supply system specification selection principle Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage. TT System: Uc 1.55Uo (Uo is low voltage system to null line voltage) TN System: Uc 1.15Uo IT System: Uc 1.15Uo(Uo is low voltage system to line voltage) Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone. SP1 Series Normal Working Conditions -Altitude not exceed 2000m -Ambient air temperature: Normal range: -5 ºC~+40 ºC Extend range: -40 ºC~+80 ºC -Relative Humidity: 30% - 90% under indoor temperature condition - At the place without obviously shaking and shock vibration - Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust) Classification -As per Nominal Discharge Current: 5,10,20,30,40,60KA(8/20 µs) - As per Maximu
Photovoltaic System with CE & TUV DC1000V-40ka Surge Protective Device (SPD) 1. Product Function Products are mainly used in the DC power supply lighting protection and over-voltage operation protection function. 2. Main features: Use high quality varistor, reliable high-quality assurance and stable performance Modular design, can be charged plug, easy to test or replace With remote alarm device, easy for remote monitoring Adopt temperature control circuit technology, over-current and over-voltage double automatic protection circuit With working and fault display, degradation status is clear at a glance Fast response time, large discharge current capacity, low residual voltage easy to install, maintain simple
APPLICATIONS: Techwin Industrial POE (Power over Ethernet) SPD (Surge Protection Device) is specially designed for Ethernet switches. The POE switch will not be damaged by lightning overvoltage, induced overvoltage, and electrostatic discharge. CAT5e and CAT5 compatible IEEE 802.3af803.1at 10/100 Base-T Ethernet protection LAN, FDDI, CDDI, ATM,WLAN PDH, SDH, SPDH Industrial control Industrial POE, With High reliability and high stability Surge protection for power supply system, SPD for low-voltage installations and device.CCTV system. FEATURES: Multi. Protection circuits, Gas-Tube+ TVS technology Dual protection in Common mode and differential mode TVS array technology, low capacitance Multi-Strike Capability Patent technology TECHNICAL PARAMETER Model POE5-48 Power Parameter Working voltage Un 48V Max. continuous operating voltage Uc 60V Nominal discharge current8/20µsIn 5kA Max. discharge current 8/20µsImax 10kA Protection level 8/20µsUp 150V Protection line 4/5, 7/8 Ethernet Parameter Max. continuous operating voltage Uc 5V Limiting voltage (10/700µs) Up Line-Ground â?¤500V Line-Line â?¤20V Nominal discharge current8/20µsIn 3kA Max. discharge current 8/20µsImax 5kA Adapt transmission rate 100Mbps Insertion loss â?¤0.5dB Protection line 1/2, 3/6
3P+N 40kA lightning surge protection device This surge protective device( hereinafter referred to as SPD) are suitable for AC 50/60Hz, rated voltage up to 380v IT,TT,TN-C, TN-S,TN-C-S and other power supply system, it protect to indirect and direct lightning effect or other transient over voltage SPD design according with GB18802.1/IEC61643-1 standard. Specification details: Model PQ2-40 Poles 4P Max. continious working voltage(Uc) 420V AC(can customized) Nominal discharge current(In) 20kA Max.discharge current(In) 40kA Voltage protection level(Up) 1.8kV Matched circuit breaker/Fuse 32A Response time
Product description Low voltage surge protective device Rated release current: 5, 10, 15, 20ka Voltage protection level: 1.0, 1.5, 1.8, 2.0kv Product feature Ebs1u surge protector protect electric and electronics equipment against transients, originating from lighting, switching of transformers, lightings and motors. These transients can cause premature ageing of equipment, down time, or complete destruction of electronic components. Surge protector are strongly recommended to install to protect sensitive and expensive electrical equipment such as tv, video, washing machine, pc etc. The main protection spds can be installed directly after the main switch or type s rccb in any supply system such as tt, tns, tncs. Product specification/models Model: ebs1u surge protector Standard: 61643-1 Max. Continuous working voltage: 140, 275, 320, 385, 400, 420, 440v Rated release current in (ka): 5 10 15 20 Max. Release current: 5, 10, 15, 20ka Voltage protection level: 1.0, 1.5, 1.8, 2.0 kv Rated voltage ue (v): 230/400 Poles: 1, 1p+npe, 2, 2+npe, 3, 3+npe, 4 Rated frequency: 50/60hz Protection level: c, d Response time:less than 25ns Standard export carton
DK-nDCt/RJ45 series network signal surge protective device(SPD) is designed according to IEC61312 standard. It is suitable for lightning protection of computer, switch and other network equipment. With features of integration metal structural design, high discharge capacity and fast response, it can ensure the equipment to work properly.
Djx specialized in carbon graphite materials and products for more than twenty years, we are confident to provide you high quality products with the most reasonable price, please join us to enjoy our quality and services. Djx supplies graphite plate for spd surge protection device with various sizes, customerized products are available depending on your pictures and drawings, we will recommend the most suitable graphite material for you, please contact us for more details. Based on the disadvantage of traditional gap surge protector (spd), and combined with the material characteristics of graphite and thompson gas discharge theory, a large scale of experiments on the new type of graphite gap spd were completed by open circuit voltage wave generator and icgs impact system. The results show that, after the high voltage trigger capacitance device was added to the new type of graphite gap spd, every gap was triggered step by step so that the voltage protection level was reduced. At the same time, the graphite gap spd is better than traditional gap spd on time delay characteristics, and is able to achieve the arc extinction requirements before the power frequency voltage dropped to zero. In addition, graphite belongs to non-metal materials; it won't produce plasma under high temperature, which can improve the stability of device and delay aging.
LZA-C Series.
800_080 BT P B80 385 RM Main Features: * Small volume, high discharge capacity * Reliable protection thanks to double control disconnector * Quick response * Low voltage protection level and with double terminals connection * Green window will change when fault occur, also in the same time provide remote alarm terminal * Core components are from international well known supplier Application: This product is designed to protect low voltage devices from surge damage, used in power supply system such as power distribution-room, distribution-cabinet and other important power supply system. Widely used to protect mobile communication station, telecommunication centre, civil aviation, finance, and so on. Specifications: Technical data Rated voltage (max. continuous voltage) Uc 385V Nominal discharge current(8/20) In 35kA Max. discharge current Imax 80kA Voltage protection level at 20kA Up í_1.8kV Response time tA í_25ns Operating temperature range -40íµí¡+80íµ Cross-sectional area 1.5mm2~25mm2(solid)/35mm2(flexible) Mounting on 35mm DIN rail Test standards GB 18802.1-2002; IEC 61643-1:1998-02 Dimension 3 mods
Video signal arrestor Applications: Designed for monitor device not to be spoiled by lightning over-voltage, induced over-voltage and static discharge. Video camera E1, pdh, sdh, spdh Digital hard disk video cassette recorder Industrial control Features: Multi. Protection circuits, gas-tube+ tvs technology Dual protection in common module and different module Tvs array technology, low capacitance Multi-strike capability Specifications: Type d12bf d12bf-4d12bf-16 Electrical specifications Impedance75++ Max operating voltage12v Nominal discharge current (8/20++s)3ka Max. Discharge current (8/20++s)5ka Protection level (3ka 8/20++s) Line to line40v Line to pe160v Adapt transmission rate100mbps Insertion lossf 0.5db Response time f 5ns Mechanical specifications Connectorbnc female to malebnc female to female Number of protection ports1416 Diamension (mm)82.7*25*25130*73*25 481*84*47 Working environments Operating temperature minimum-40 Operating temperature maximum85 Operating humidity95%
Applications: Designed for monitor device not to be spoiled by lightning over-voltage, induced over-voltage and static discharge. Video camera E1, pdh, sdh, spdh Digital hard disk video cassette recorder Industrial control Features: Multi. Protection circuits, gas-tube+ tvs technology Dual protection in common module and different module Tvs array technology, low capacitance Multi-strike capability Specifications: TypeD12bfD12bf-4D12bf-16 Electrical specifications Impedance75+ Max operating voltage12v Nominal discharge current (8/20s)3ka Max. Discharge current (8/20s)5ka Protection level (3ka 8/20s)Line to line40v Line to pe160v Adapt transmission rate100mbps Insertion loss_0.5db Response time _5ns Mechanical specifications ConnectorBnc female to maleBnc female to female Number of protection ports1416