Execution standard GB 1094.1-2 power transformer general rules, power transformer temperature rise GB 1094.3 power transformer insulation level and insulation test GB 1094.5 "power transformer capacity to withstand short circuit" GB/T 6451 technical parameters and requirements of three-phase oil-immersed power transformer GB/T 15164 load guide for oil-immersed power transformer IEC76 power transformer GB 2536 "transformer oil" 800KVA~31500KVA three-phase double-winding non-excitation voltage regulating power transformer:
Dry type transformers shall be installed in accordance with the manufacturer's requirements, and shall be equipped with temperature measuring devices, generally 630kVA and above transformers. A,1000kVA and above oil-immersed transformer shall be equipped with an outdoor signal thermometer and can take distant signals. Product features: A, tank using corrugated sheet, it has the respiratory function to compensate for temperature change caused by the oil volume change, so the product without oil storage tank, obviously reduce the height of the transformer. B, because the corrugated film replaces the storage tank, the transformer oil is isolated from the outside, thus effectively preventing the entry of oxygen and water and the decrease of insulation performance. C, according to the above five performance, to ensure the oil-immersed transformer within the normal operation of the don't need an oil change, greatly reduces the maintenance cost of transformer, and prolong the service life of the transformer. D. In addition to the small capacity of copper wire, copper foil is usually used in the cylinder structure. The high voltage winding adopts multi-layer cylindrical structure to balance the ampere-turns distribution of the winding, the leakage is small, the mechanical strength is high, and the anti-short circuit capability is strong. E, iron core and winding each adopt the fastening measure, the height of the device, the low voltage lead wire and other fastening parts are equipped with self-locking anti-loose nuts, adopt the non-lifting structure, can withstand the shock of transportation. F, coil and iron core adopt vacuum drying, the transformer oil adopts vacuum filter oil and oil filling process, which minimizes the moisture in the transformer.
Dry type transformers shall be installed in accordance with the manufacturer's requirements, and shall be equipped with temperature measuring devices, generally 630kVA and above transformers. A,1000kVA and above oil-immersed transformer shall be equipped with an outdoor signal thermometer and can take distant signals. Product features: A, tank using corrugated sheet, it has the respiratory function to compensate for temperature change caused by the oil volume change, so the product without oil storage tank, obviously reduce the height of the transformer. B, because the corrugated film replaces the storage tank, the transformer oil is isolated from the outside, thus effectively preventing the entry of oxygen and water and the decrease of insulation performance. C, according to the above five performance, to ensure the oil-immersed transformer within the normal operation of the don't need an oil change, greatly reduces the maintenance cost of transformer, and prolong the service life of the transformer. D. In addition to the small capacity of copper wire, copper foil is usually used in the cylinder structure. The high voltage winding adopts multi-layer cylindrical structure to balance the ampere-turns distribution of the winding, the leakage is small, the mechanical strength is high, and the anti-short circuit capability is strong. E, iron core and winding each adopt the fastening measure, the height of the device, the low voltage lead wire and other fastening parts are equipped with self-locking anti-loose nuts, adopt the non-lifting structure, can withstand the shock of transportation. F, coil and iron core adopt vacuum drying, the transformer oil adopts vacuum filter oil and oil filling process, which minimizes the moisture in the transformer.
Low loss, low noise level, high stability This series product possesses four low and one high characteristics which are: low lose. Low noise, low temperature rising.Low partial discharge and high reliability, as well as core-hoisting free and no leakage. With the approval of national transformer quality inspection and testing center. Allthe index of the transformer achieve jb/t3837 standard
This standard is applicable to three-phase double winding oil immersed power transformer with voltage class 35kV, rated capacity 50 ~ 31500kVA and frequency 50Hz. Â This standard is not suitable for dry and damp heat belt type power transformer and power plant, transformer substation own three phase power transformer.
Performance parameters of S13 type 10kV double winding series: Type rated capacity (KVA) connection group label voltage combination (KV) no-load loss (W) load loss no-load current (%) short circuit resistance (%) High pressure range low Dy Yy. 10 10 Yyn0 / S13 - M - or Dyn11 10 6.3 6 + / - 5% Plus or minus 2 x 2.5% or + 3 x 2.5% -1 x 2.5% 0.4 40 360 340 2.8 4.0. S13-M-20, 70, 525, 500, 2.5. S13-M-30, 30, 80, 630, 600, 2.3. S13-m-5050 100 910 870 2.0. S13-m-63, 110, 1040, 1040, 1.9. S13-m-80 130 1310 1250 1.9. S13-m-100, 100, 150, 1580, 1580, 1580. S13-M-125, 125, 170, 1890, 1800, 1.7. S13-m-160, 200, 2310, 2200 1.6. S13-M-200, 240, 2730 2600 1.5. S13-m-250, 250, 290, 3,050, 1.4. S13-m-315 315340 3830 3650 1.4. S13-m-400, 4410, 452043001.3. S13-m-500, 480, 5410, 5150, 5150. S13-M-630 630 570 6200 6200 1.1. S13-m-800, 700, 7500, 7500, 1.0. S13-m-1000, 830, 10300 10300 1.0. S13-m-1250, 1250, 970, 12000, 0.9. S13-m-1600 1,170 14500 14500 0.8. S13-m-2000, 1510, 17800, 17800.0.8, 5.0. S13-M-2500, 1780 20700 20700 0.7. S13-m-3150 3150 2100 24300 24300 0.7.
Product features 1. The transformer core is made of imported high quality cold rolled silicon steel, which greatly reduces the no-load loss and no-load current, and the core is bound to ensure the tightness of the core and reduce the noise. 2. The high and low voltage winding is made of anaerobic copper, and the low-voltage winding 500kVA and the following are double-layered cylindrical structures. A double helix or four-helix structure is used in 630kVA and above. Multi-layer cylindrical structures are used for high voltage windings. 3. The transformer connection group adopts Dyn11 to reduce the influence of harmonics on the power grid and improve the quality of power supply. 4. The transformer is full seal structure, extending service life, free of hanging core and maintenance. 5. The measured noise is below the standard. After normal transportation, the series of transformers can be installed with relevant parts, and the test of acceptance test can be put into operation.
Our oil-immersed power transformers have stable operation, high safety and efficiency, low price and wide application. Oil-immersed power transformers are integrated with production, sales and installation, with strong strength and good reputation. Our oil-immersed power transformers have stable operation, high safety and efficiency, low price and wide application. Oil-immersed power transformers are integrated with production, sales and installation, with strong strength and good
Power Transformer (35kV) Oil-immersed Transformer Products structure and technical features The oil-immersed transformer produced by our factory have these advantages: low loss, low noise, high short circuit strength and good appearance. We company create these prefect products of that each parameter has reached to advanced level among domestic similar products by combining advanced manufacture equipments and technology. Structure features: Core and main body: it is used iron core cutting line ,all inclined ladder joints and improving flux trend to eliminate flux saturation phenomenon of iron core in joints . By doing these, it reduces the no-load loss, no-load current and noise of transformers. Adopting pulling-plank structure, in order to strengthen the ability of withstanding short-circuit, we put many nails around pressing planks and bracing plates are used as support between H.V and L.V yoke, make the iron core be a whole. The iron core sheet are coated by glue which are specialized for silicon steel , so that all silicon steels can be bonded together to make the iron core be  integral one, this effectively enhances mechanical strength and plays a positive role in the core anti-rust. The low part of the body and the oil tank are supported through bracing plates adopt" high intensity electric laminated" technology, to guarantee the low part of oil-immersed transformer's body safe and reliable. Coil: The high-voltage(HV) coil adopts an interleaved-continuous structure, The low-voltage(LV) coil adopts an interleaved-continuous or spiral structure, are independently provided with voltage-regulating winding to balance the ampere turn of each winding-up, effectively lower the mechanical force to minimal level. In the transformer winding, there is a zigzag oil guide structure so as to fully cool all areas inside the winding, lower the temperature rise of the winding and the hot points of the winding and prolong the service life of insulation. Oil tank: the tank's structure of oil-immersed transformer is bell jar type or suspended type, have a good looking and high mechanical strength. It adopts" flanged joint" technology in every key point (such as annular tubes, pressure valves, switches,etc.), which effectively avoid leaking oil. Technical Parameter and features Technical specification 1,voltage:35kV 2,voltage regulation: on load tap regulation ,off circuit tap regulation 3,capacity range:
35kv grade transformer is with the following characters: low loss, low noise, protection for thunder and lighting, and anti-shortcut capacity, beautiful appearance etc. It is made by advanced assembling lines and method, with qualified parts. It is with for remote functions: remote communication, remote test, remote adjustment, remote control. By remote control from a computer, the power station could be free from supervision in the office. Type "9" 35kv grade series energy saving transformer has passed the test by national mechanical and industrial bureau, and national power group. 35kv grade series transformer mainly use in power network, and the projects of power distribution. Main functions and characters • core is with advanced three steps: vertical and horizontal and horizontal cut, lap and multi-stage. It disperses the air distribution, improve the magnetic path. Decrease the empty loading loss, current and noise. • core with dragged panel, pressed the coil, particular glue for silicon steel; a set of measures to increase the mechanical strength. • new structure of high and low voltage wrapping, reasonable arrangement for oil tube and connection, increase the capacity of mechanical strength and anti-shortcut. • oil box is bell type or core suspension type, the wall of oil box is as wave form. Packed in wooden case
main parameter of 69kv CT Rated current ratio: 2000/1600/1500/1200/1100/800/500/400/300 : 5 A Rated output capacity of each corresponding ratio: 200/160/150/120/110/80/45/35/25 VA Winding accuracy class: 0.2/5P20/5P20/5P20 CNMEs business activities cover national and international engineering, Generation Stations, Electrical Engineering Equipment, all kinds of electrical equipment, Test And Design and so on. The activities consist of the industries of high voltage power transmission and distribution, diesel power generation, thermal power generation, Transformer Test Laboratory Design, Electrical Lab Design And Solution, Power Plant Design and so on.
4cst, 6cst, 8cst, etro4, etro6, naphthenic base oil, equinas 4 group 3 base oil, equinas 6 group 3 base oil, equinas 8 group 3 base oil, equinas tfo 60i high quality inhibited transformer oil, equinas tfo 60u high quality un inhibited transformer oil, drilling fluid, melamine powder, clinker, urea, chemicals, base oils and other petroleum products, industrial salt.Marine transportation and logistics marine ship and cargo survey and inspections
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Current ) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A 1.5 50 30 200 7.5 500 10 3 50 60 200 15 500 10 5 50 100 200 25 500 10 10 50 200 220/380 50/26 500 10
Product specifications Rated power: 2500kVA Voltage: 22/0,4kV Winding connection: Dyn11 No-load loss (Po): 1850 W Short-circuit loss(Pk): 21000 W Max. no-load current(I0): 1.5% Short circuit voltage(Uk ): 6% Standard: : TCVN 6306 (IEC 60076); Decision 62 / Q EVN (Vietnam), ISO 9001:2015; ISO 14001:2015 (International).
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity High Frequency Voltage Output Voltage High Frequency Voltage Output Currentm) Low Frequency Voltage input Change Tempera- ture raised 30 minute V A YD G1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G 5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G 20 20 50 400 380 53 500 10 YD G 30 30 50 600 380 79 500 10 YD G 40 40 50 800 380 105 500 10 YD G 50 50 50 1000 380 132 500 10
Product Details: Name:Auto transformer Usage:Power Phase:Three Coil Structure:Thyroidal Rated capacity:30-3000kvaT Type:Oil immersed Input Voltage:5-35kV Output Voltage:0.4/0.23kV Material:Copper Cooling Method:Oil Natural Frequency:50/60Hz Rated voltage:20KV
Base oil sn60, 70, 100, 150, 350, 400, 500, 550, 600, 650; jet fuel a1, jp54, crude oil, bitumen 50,60/70, 90/100 & all grades of bitumen, used cooking oil, transformer oil, industrial oil, all types of grease, lng/lpg, used motor or engine oil, all types of motor oil, lubricants, additives and types of petroleum products.
Product description The test transformer calls the booster, it is the basic test equipment used by the power station, supplying and distributing the electrical power system and the scientific research unit. Which used in the insulated intension test on all kinds of electrical products, electrical equipments and insulated materials, testing the insulated level of products, discovering the insulated objection of quizzee, scaling the capacity burdened voltage Oil Immersed Testing Transformer 1 Technical index Model Capacity KVA High Frequency Voltage Output Voltage KV High Frequency Voltage Output Current mA) Low Frequency Voltage input Change Tempera- ture() raised/ 30 minute V A YD G -1.5 1.5 50 30 200 7.5 500 10 YD G 3 3 50 60 200 15 500 10 YD G-5 5 50 100 200 25 500 10 YD G10 10 50 200 220/380 50/26 500 10 YD G20 20 50 400 380 53 500 10 30 50 600 380 79 500 10 40 50 800 380 105 500 10 50 50 1000 380 132 500 10 100 100 100 500 263 1000 10 150 100 1500 500 300 1000 10 200 100 2000 500 400 1000 10
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission. Product Description The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission. S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior. Product Features Good Economic Performance The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series. Long Service Life Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil wont contact with air, so that extend the service life effectively. High Operation Reliability Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal. Small Installation Area S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
Soda ash light / dense 99.2% sodium bicarbonate caustic soda flakes 99% sodium sulphate anhydrous (ssa) 99% sodium sulphite flakes (ssf) 60% sodium metabisulphate hydrogen peroxide (h2o2) 50% formic acid 85% glacial acetic acid paraffin wax liquid paraffin (white oil) lp 100 menthol crystal fumed silica deg (di ethylene glycol) mono ethylene glycol (meg) poly ethylene glycol (peg), base oil 150n, bs 150, 600n bitumen 60/70 rpo (rubber process oil) lioh (lithium hydroxide) hco (hydrogenated castor oil) 12 hsa (hydroxy stearic acid) ferrous sulphate heptahydrate additive for lubricating oil aromatic chemicals.Exporting of chemicals & other products