CFX Opus 96 Real-Time PCR Instrument 0.2 mL, 96 Wells Product Details: Brand BioRad Model Name/Number CFX Opus 96 Sample Capacity/Format 96 wells Multiplex analysis Up to 5 targets per well Dimensions (W x D x H), cm/in 33x56x36 / 13x22x14 Cat No 12011319 Description CFX Opus is the newest real-time PCR system in our robust CFX Family. The CFX Opus 96 Real-Time PCR System can analyze 96 wells and offers a number of new features: More uniform thermal performance Expanded connectivity Wi-Fi, ethernet, and USB Cloud connectivity: Operate CFX Opus on our BR.io cloud platform or with desktop CFX Maestro Software Network storage drive access for excellent data management Shuttle optical system yields consistent optical measurements across your sample plate SpecificationsThermal CyclerMaximum ramp rate, C/sec5Average ramp rate, C/sec3.3Heating and cooling methodPeltierLid, C30 110 Temperature Range, C4 100Accuracy, C ±0.2 of programmed target at 90 C Uniformity, C ±0.3 well-to-well after 10 sec of arrival at targetGradientOperational range, C30 100Programmable span, C1 24Optical DetectionExcitation6 filtered LEDs Detection6 filtered photodiodes Range of excitation wavelengths, nm450 684 Range of emission wavelengths, nm510 730Sensitivity Detects 1 copy of target sequence in human genomic DNADynamic range10 orders of magnitudeScan TimeAll channels, sec12 FAM/SYBR Green only, sec3SoftwareOperating systemWindows 10Multiplex analysisUp to 5 targets per wellSystemSample capacity, wells96 Sample size, µl150 (10 50 recommended) Communication interface USB 2.0 Electrical approvalsIEC, CE Dimensions (W x D x H), cm/in33x56x36 / 13x22x14Weight, kg/lb22/48
Hi-PCR Coronavirus (COVID-19) Multiplex Probe PCR Kit Product Details: Number of Reactions(Preps)/Kit : 100 Rxns Per Box Brand : HIMEDIA Storage Temperature : -10 to -20 C Detection : Probe Based Target : E, N and RdRp gene. Cat No : MBPCR243 Description A ready to use Rt-PCR Kit for Detection of Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease 2019 (COVID-19). SARS-CoV-2 is a coronavirus, subgenus Sarbecovirus, 150-200nm in diameter with a genome size of about 30 Used For A ready to use Rt-PCR Kit for Detection of Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease 2019 (COVID-19).
HPV is a virus that causes papillomas (benign tumors), and about 200 types have been discovered so far. Some types of HPV are known to be the direct cause of cervical cancer, head and neck cancer, etc. In particular, in the case of cervical cancer, more than 99% of the causes are reported to be caused by HPV. If it is detected early, it is easy to treat, but if it is detected late, the 5-year survival rate is less than 15% even with treatment, so regular check-ups are very important. SML Genetree has developed the world's first Ezplex�® HPV NGS Kit to diagnose HPV using the NGS method. Unlike the existing methods that only detected up to 20 to 40 types and only positive-negative, NGS was introduced to provide positive results for 45 types of HPV (up to 100 types including for export) according to the amount of DNA detected in steps 1 to 3 Semi-quantitative inspection of the level is possible. It has a high level of automation that is close to full automatic. The time has been shortened so that up to 480 people can be analyzed within 16 hours with one analysis, and it is possible to distinguish HPV species that were difficult to distinguish precisely. Unlike the existing sequencing method, the NGS method has been highly evaluated for its potential as a precision medical technology that can dramatically reduce time and cost by analyzing numerous DNAs at high speed. As a result of clinical efficacy evaluation with more than 2500 clinical specimens in large domestic hospitals, it is a product with high sensitivity and specificity compared to existing tests.
Ezplex MTBC/NTM Real-time PCR Kit is an in vitro diagnostic test that simultaneously detects Mycobacterium tuberculosis complex (MTBC) and 20 types of nontuberculous mycobacteria (NTM). Sensitivity : Multiple gene targets for MTBC and NTM. Clinical Performance: Validated clinical performance. Fast Results: Testing can be completed within 2 hours post extraction.
Ezplex Respiratory Pathogens Real-time PCR Kit is an in vitro diagnostic test for the qualitative detection of 19 respiratory viruses and 6 types of pneumonia-causing bacteria through nucleic acids isolated and extracted from human throat swabs using real-time polymerase chain reaction Comprehensive Panel- One test can identify 19 respiratory viruses and 6 bacterial species simultaneously. Sensitivity Detection of all targeted viruses and bacteria with high sensitivity. Convenience Genetree Viewer analysis software available for users to conveniently produce test results. Clinical Performance: Clinical testing confirmed the high sensitivity and specificity. Stability: Shelf life of up to 12 months. Analytical Specificity: Testing of 31 species of microorganisms showed no cross reactivity.
Ezple Respiratory Pathogens Real-time PCR Kit is an in vitro diagnostic test for the qualitative detection of 19 respiratory viruses and 6 types of pneumonia-causing bacteria through nucleic acids isolated and extracted from human throat swabs using real-time polymerase chain reaction.
MTBC/NTM Real-time PCR Kit is an in vitro diagnostic test that simultaneously detects Mycobacterium tuberculosis complex (MTBC) and 20 types of nontuberculous mycobacteria (NTM).
HP-CLA Real-time PCR kit is an in vitro diagnostic test that qualitatively detects helicobacter pylori and Clarithromycin-resistant mutations from human gastric biopsy tissues. Contains multiple gene targets to detect Helicobacter clarismycin-resistant mutations. Genetree Viewer analysis software is provided, allowing users to conveniently check results.
HLA-DRB1 NGS typing Kit is an in vitro diagnostic test that detects and distinguishes allelic genes of HLA-DRB1 in human leukocyte antigens at high resolution using next-generation sequencing. Ezplex's unique amplicon approach simplifies the traditional complex NGS Library construction process and provides dedicated software optimized for HLA typing for easy analysis. The Ezplex�® HLA-DRB1 NGS typing Kit accurately reads the HLA-type Acuracy % (95% Confidence Interval) in DRB1 Locus within a total of 35 hours from DNA extraction to NGS results analysis to help with pre-transplant testing.
SFTS Virus Real-time PCR Kit is an in vitro diagnostic test intended for the qualitative detection of the Dabie bandavirus that causes Severe Fever with thrombocytopenia Syndrome using nucleic acid RNA extracted from human blood or serum. Clinical evaluation performed with human blood specimens confirmed clinical accuracy. High reproducibility with similar results were confirmed various tests.
Real time PCR instrument. With 16-, 48-, or 96- wells. with 4-. 5-. or 6- channels.
Fosun RT-PCR COVID19 test kit whitelisted BSA L2 Lab professional use only, cold storage container required at additional cost Detection time 1H2, full process 2H, overall coincidence rate 97.49% $7 per test, available in 24/48/96 per kit. MOQ 300K test, EXW TT. Please inquire for further technical information.
Authorized agent for Turkish manufacturer of RT-PCR for COVID test kit; comes with US FDA EUA Approval Packing : 100 tests/kit
OUR AUTHORIZED BIO TECH FATORY HAD QUICKLY TEST KIT (Saliva in 10 minutes 94.6-99.7% accurate, the world's most advanced, Europe, Canada, big seller) ANS PCR FROM SOUTH Korea Pls Send The Loi To Long Turn International Consulting Group Ltd
Specification: 50T/kit or 100T/kit vial; 48T/kit or 96T/kit 0.1mL 8 strips/0.2mL 8 strips. Canine distemper virus(CDV) is caused by a single-stranded RNA virus of the family . The disease is highly contagious via inhalation. The distemper virus real time PCR detection kit is intended for the qualitative detection of Canine distemper virus in samples by using real time PCR systems.
GOLD STANDARD for diagnosis novel coronavirus. This kit is based on one-step RT-PCR technique. Used for the in vitro qualitative detection of novel coronavirus (2019-nCoV) ORF1ab and N gene in the throat swabs, sputum specimens of suspected pneumonia patients infected by novel coronavirus, suspected clustering cases and others needing diagnosis or differential diagnosis for novel coronavirus. No cross-reaction, sensitivity is 500 copies/ml. CFDA/CE. Applicable Instruments include ABI 7500 & LightCycler480.
RT-PCR direct Detection Kit is intended to be used to achieve direct detection of Severe acute respiratory syndrome coronavirus 2 viral RNA from nasal swabs, nasopharyngeal swabs and oropharyngeal swabs from patients with signs and symptoms of infection who are suspected of COVID-19. This product provides dual-detections of two independent genes of a single tube. gene and N gene is amplified and detected in FAM and HEX channel, respectively. An internal control is set with a Cy5 labeled probe using the RNase P gene of human as the target, to monitor the amplification effect of the detection system. Our nucleic acid detection reagent can be transported at room temperature by freeze-drying technology, and can be stored at low temperature for a long time for one and a half years, and maintain good effectiveness.
Dear sir we are korean trading company we supply the covid-19 test kit from korean factory we supply 1.RT-PCR test kit 2.Antibody test kit 3.Antigene test kit
Multiplex One Step RT-qPCR Probe Kit is a multiplex quantitative PCR kit based on RNA as template. In the process of the experiment, reverse transcription and quantitative PCR were carried out in the same tube, which simplified the experimental operation and reduced the risk of contamination. In this kit, the first strand cDNA was efficiently synthesized by heat-resistant Hifair V reverse transcriptase and quantitatively amplified by UNICON HotStart Taq DNA polymerase. The kit mainly contains optimized MP buffer, enzymes mix, etc. The buffer solution already contains Mg2+ and dNTP. In addition, the factors that can effectively inhibit the non-specific PCR amplification and improve the amplification efficiency of multiple qPCR reactions are added, which can ensure the amplification efficiency and carry out up to four reactions. Quantity: 100 T, 1000 T, 10000 T Applications: RT-qPCR, 4-plex reaction Sample Type: RNA template main enzyme: Hifair V Reverse Transcriptase,UNICON HotStart Taq DNA Polymerase Category: IVD PCR Research Area: RT-qPCR
UE had been striving to develop and enhance our products to empower anesthesiologists to convey a sense of expertise in all possible conditions, being fully aware that anesthesiologists race against time to save lives, and the primary step is tracheal intubation in a few precious seconds. UE integrates R&D, manufacturing, sales, and after-sales service. Our products are CE, FDA, South Korea KFDA, and CFDA approved and have complied with local regulatory requirements from different countries. Display 3" TFT LCD, 720x480 px Tilt and Rotation 0-110 tilt, 0-270 rotate Memory 32G, take> 400k photos, record 16 hrs of video Bettery Life 3.5 hrs on a full charge