Power supply (AC/DC) AC 85-265V/DC 85-330V Power consumption:
Power supply (AC/DC) AC 85-265V / DC 85-330V Power consumption:
FU2200A Ethernet power meter has the PC software and the data logger function, which can set by end users from 1min to 60min intervals to record. You can read the data through a PC. Also, you can share the data in the Internet LAN. By the way, it can measure the harmonics. Back of power meter FU2200A with Ethernet port as photo shows here. FEATURES True-RMS measuring parameters ANSI and IEC 0.2 accuracy class Power quality analysis 4 quadrant energy 2MB onboard memory, can be extended to 16M Data logging High-speed RS485, Ethernet port (option) Measure individual harmonics from 2nd to 63st (option) TOU, 4 Tariffs, 6 Seasons, 6 Schedules Three years warranty With PC management software; web browse data APPLICATIONS Metering of distribution feeders, transformers, generators, capacitor banks and motors Medium and low voltage systems Commercial, industrial, utility Power quality analysis Data logging Monitoring system Power Supply (AC/DC) AC85-400V / DC85-330V Power consumption:
Using electrical parameters means using several analog or digital single-function products such as ammeters, voltmeters or watt meters. BJ194E-2SY, with its four direct access keys and LCD displays, helps you use all the parameters in 3P3W or 3P4W LV installation. These parameters can be centralized on a PC or PLC through an RS 235 link using MODBUS protocol. The casing is designed so that the installer can easily fit the meter to the door of a cabinet. To facilitate and optimize the operators work, the BJ194E uses one of the most functional principles for integrating communications or metering.
Using electrical parameters means using several analog or digital single-function products such as ammeters, voltmeters or watt meters. The BJ-194e-3S4 is a digital LV three-phase measurement device. It displays simultaneously on the 3 phases the most frequent values for an electrical installation or for monitoring generator sets.
Using electrical parameters means using several analog or digital single-function products such as ammeters, voltmeters or watt meters. BJ194E-9SY, with its four direct access keys and LCD displays, helps you use all the parameters in 3P3W or 3P4W LV installation. These parameters can be centralized on a PC or PLC through an RS 235 link using MODBUS protocol. The casing is designed so that the installer can easily fit the meter to the door of a cabinet. To facilitate and optimize the operators work, the BJ194E uses one of the most functional principles for integrating communications or metering.
Especially developed for indication and supervision of the three-phase circuit, can expand the measurement range, replaces old analogical meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, can expand the measurement range, replaces old analogical meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Data: 1.Measuring current:0-5A 2.Measuring voltage:0-100V 3.Accuracy class:1.5 4.Operating temperature:-20~50 5.N.W:195G G.W:245G 6. Product Description Composition: Glass window, ABS Resin frame and case, PC glass fiber base mounting fitting included. Scale Plate: The normal scale plate is made of alloy-aluminium material white printed with black scales,Values, units, technique symbols, etc. Scale plate with special requirements are available upon request. Such as color, scale with lighting functions and PVC noctilucence are available upon request. Color: Black base and frame , white scale plate and meter body. Pointer: Normaly, the pointer is made of alloy-aluminium, it is black, and red, white are available Upon request. Anti-static: All meters are subject to anti-static treatment to minimize the static-effect to the accuracy of the meters. Damping and Overshoot: The overshoot is less than 15% when the pointer is at the 2/3 of the scale. Damping and overshoot can be customized according to userâ??s requirements. Accuracy: BE-96W A/V-Class 1.5 BE-96W COSΦ-4degree in phase angle BE-96W HZ-Class 1.5 FULL SCALE DEFLECTION:250 degree Service condition: -20~+50 degree; Operating position: Generally, meter is installed in vertical position. Other installation position can be customized (please specify the desired angle).The accuracy class is just valid for the Corresponding installation mode. Insulation Test: The test Voltage for BE&BP series is 2KV RMS for 1 minute with the frequency 50Hz. Safety Precautions: Meters with damaged bezels or glass faceplates must be disconnected from the mains. Scale plate, front frames and windows may only be replaced under voltage-free conditions. The meter should be kept clean, if the meter is used in a manner not specified by the manufacturer, the protective function may be impaired. Meters with Auxiliary Lighting In order to read the indicating values in darkness,KDSI provides Meters with lighting functions.Power can be AC/DC:12V,24V,110V.
New 194J series Smart Power Manager is the more powerful meter than 194Y series power analyzer. With higher precision and more measurement parameters. This meter is the latest series meter developed in 2015 by Blue Jay tech. It is the ideal choice for monitoring and controlling of power distribution systems. Application ·Provide remote fire alarm. ·Temperature data reading. ·Harmonic analyze. ·Remote data reading. ·Alarm station with voltage-free digital inputs. Features ·Class 0.2 power and energy ·Current measuring .../5 or .../1 A ·Backlit LCD display ·Expandable input / output modules (up to 3 modules) ·With RS-485 Modbus/RTU Communications ·Measured varies of power parameter. (Max demand/unbanlance/crest factor/K factor...) ·Optional 2 channel Digital Input (DI) and 3 channel Digital Output (DO) ·Record and read multi- tariffs ratio, Up to 3 months ·Provide max 50 lists SOE record function ·ITF Technology: galvanic insulation protection inputs outputs ·Universal series power supply (85-265VAC/DC)
BJ194E-9S4, with its four direct access keys and LED displays, helps you use all the parameters in 3P3W or 3P4W LV installation. These parameters can be centralized on a PC or PLC through an RS 235 link using MODBUS protocol. The casing is designed so that the installer can easily fit the meter to the door of a cabinet. Applications 1. Metering of distribution feeders, transformers, generators, capacitor banks and motors 2. Medium and low voltage systems 3. Commercial, industrial, utility Features 1.Class 0.2 or 0.5 power and energy 2.Current measuring .../5 or .../1 A 3.Option RS-232 Modbus/RTU Communications 4.Expandable input / output modules (up to 3 modules) 5.ITF Technology: galvanic insulation protection inputs outputs 6.Universal series power supply
Especially developed for indication and supervision of the low-medium voltage three phase electrical network measurement also can be used in DC circuit. It can replaces other analogical panel meter reducing installation manpower and optimizing the used one of spaces in the panel. Features: ·Class 0.5(192 series)/0.5S(193 series) electrical parameter measurement ·Current measuring .../5 or .../1 A ·Measurement function cover: Current, Voltage, total three-phase power, power factor, frequency ·RS-485 MODBUS-RTU Communications ·Expandable input / output modules (1 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Large character LED Screen display ·Optional various install sizes
Product Description ADL10-E Single Phase Electric Energy Meter General ADL rail- installation Electricity meters is a new generation electricity meter developed by Acrel Co,.Ltd, resulting from many years experience in designing Electricity meters. LCD display and electricity pulse output function is installed in the power meter; clock, rate period parameters can be set also. Data swap with the super ordination machine via RS485 communication interface greatly facilitate the power automated administration. This power meter has advantages of smaller volume, high precision, good EMC, easy installation etc, meet the related technical requirements of electronic power meter in the IEC62053-21,IEC 62053-22 standard. Technical Parameters Voltage Reference voltage AC 220V Reference frequency 45-65 Hz Consumption
Current : 99t1-a sq48-a Voltage : 99t1-v sq48-v Frequency : 99t1-hz sq48-hz Power : 99t1-kw sq48-kw Power factor : 99t1-cos sq48-cos
AEM-DRB Multi-Circuit Power Meter (DIN rail) Because of the climate change and global warming crisis caused by excessive carbon dioxide emissions, energy conservation and carbon reduction have become an important issue for the protection of the planet and policy work that must be addressed; The EU also plans to set up a carbon economy model to tax carbon emissions and forcefully call for carbon reduction to protect the planet. Now is no longer facing the social responsibility of energy conservation and carbon reduction slogan, but the cost of market competitiveness impact. In response to this trend and customer power monitoring needs, ADTEK used high-performance advanced microprocessors and high-resolution fast sampling AD converters to design and develop AEM-DRB multi-loop power meters, combining the three advantages of small size, easy installation and reduced unit cost, and based on longterm customer experience, designed a number of innovative features to meet the diverse applications of different fields. The AEM-DRB series of multi-loop power meters are designed for multi-loop power measurement requirements. It has 2 independent and isolated main circuit inputs, up to 24 single phase or 8 three-phase circuits, and different circuit phase wires can be mixed and matched. It is suitable for diversified use in various power loop occasions,which greatly saves costs. It also has standard RS485 Modbus communication, input, output interface, LCD display,demand, TOU, data logging function and 2MB memory capacity. The second port of communication is also optional,which makes the application more diversified. Din rail mounting, compact and easy installation, programming through computer and push buttons easy to use.
This AN8721PV3(F) series AC/DC power analyzer adopts STM32 controller as the core and supplemented by FPGA, using direct sampling and intelligent identification technology, widely used in electrical measurements of single-phase electrical equipment, such as voltage, current, power, power factor, frequency, electrical energy, time etc., wide range, 4-window LED highlight, simple operation, U disk read/write, serial communication, parameter alarm, voltage/current ratio settings and other functions, multi-purpose, accurate and durable. Features: AC/DC universal wide-range, DC ~ 4kHz bandwidth, load adaptability; Reliable, stable, compact, light; High measurement speed, up to 0.25s refresh rate; Voltage/current ratio setting, easy expansion; Voltage, current, power over-limit sound and light alarm, quick identification of abnormal products; Standard RS-232 or RS-485 serial port, MODBUS communication, test automation; Optional digital I/O, remote input and alarm signal output. Applications: Strict industrial site type test; High temperature aging room test; Home appliances, commercial appliances line standby power measurement; Power tools test; Lighting test.
The Cellular Electricity Power IoT RTU is a powerful smart meter used for power internet of things solution, is special using for remote monitoring 100~400VAC of 3-Phase electricity power distribution safety and measurement, can measuring the 3-phase 3-wire, 3-phase 4-wire distribution power voltage, current, factor, watts, frequency, apparent power, active power, reactive power, active energy, reactive energy. Also, it provides Dual SIM, 2 digital inputs, 2 relay outputs, 1 ambient sensor input for monitoring onsite temperature and humidity, also 1 RS485 for extend I/O to monitoring oil level and temperature or read meters. 1. Can be operated from anywhere, no distance limitation; 2. Quad band 850/900/1800/1900Mhz GSM GPRS Module inside. 3. 3G/4G/NB-IoT Modules are optional, LCD Display is optional; 4. Modular design, can easily upgrade the cellular module if network upgrade; 5. Embedded ARM�® Cortexâ?¢-M4 32 Bit RISC Core, 168 MHz inside, RTOS system, reliable performance with anti-jamming and in-built watchdog; 6. High isolate voltage, current and voltage input signal isolated by accuracy transformer, afford arrive DC2500V; 7. Working Voltage: 60~500VAC or 70~800VDC; 8. 3-phase 3 wires or 4 wires power parameter measurement, include voltage, current, factor, watts, frequency, apparent power, active power, reactive power, active energy, reactive energy, phase loss; 9. Measurement range: AC100~400VAC, currant range: 5A, other range should use CT; 10. 2 digital inputs, compatibles dry and wet contact, 2 relay output (5A/30VDC, 5A/250VAC), compatibles pulse outputs; 11. 1 ambient sensor input for monitoring onsite temperature and humidity ; 12. 1 RS485 port, supports Modbus RTU Master and Slave, can be used to extend I/O ports or meters; 13. Provides 1 channel DC power source output for external device, saving wiring cost; 14. Each parameter can setup threshold, when exceed or recovery will alarm immediately; 15. Can monitoring phase loss, when occurs will alarm immediately. 16. Inbuilt inter-lock logic programmer and powerful timer program function. 17. Resend the data while communication failure and alert to users by SMS; 18. Inbuilt TCP/IP protocol stack, supports cloud, APP and web server applications; 19. Supports Modbus TCP, Modbus RTU protocol and transparent transmission, can be used as master and slaves, can integrate to SCADA, HMI, DSC directly; 20. Supports USB setting, reading, records inquiry and firmware upgrade;
.1 Description DEM8900-1/DEM8900-2/DEM8900-3 (short form for DEM8900) is designed by adopting the updated microprocessor and digital signal processing technology, which can be applied for monitoring the electrical system. DEM8900 can measure and analyze the real time electrical parameters, such as I,kWh,kvarh., Meanwhile, DEM8900 has functions of multi-tariff,RS485 communication ( MODBUS protocol),analog output, remote input and electrical pulse output. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured, and tested in accordance with Quality Assurance System ISO 9001. 1.2 Measured parameters Note 1. DEM8900-1 measure current, active energy, active power (optional, with analog output) 2. DEM8900-2 measure current, reactive energy, reactive power (optional, with analog output) 3. DEM8900-3 measure Current, active energy, reactive energy, active/reactive power (optional, with analog output) 1.3 EMC and Safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
An electric meter, or energy meter, is a device that measures the amount of electric energy consumed by a building, tenant space, or electrically powered equipment. Electric utilities use electric meters installed at customers' premises to measure electric energy delivered to their customers for billing purposes
Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Gas Or Smoke Analysis Apparatus.