Output Type:AC Three Phase Speed:1500RPM Frequency:50HZ Rated Power:100KVA/80KW Rated Voltage:400/230V Rated Current:144A Standby Power:110KVA/88KW engine brand:CUMMINS alternator brand:Engga Controller:Smartgen Fuel:Diesel Certificate:ISO9001:2008 Function:Soundproof / Waterproof canopy, ATS Cooling way:water-cooled DIMENSION:2200*800*1320MM Rated capacity of battery:120AH(2PCS) Rated capacity of circuit breaker:200A Power factor:0.8lagged Global Warranty:12 months / 1000 running hours
1.Main technical data of gensets 1.1ModelCcfj50jy 1.2Prime power50kw/63kva elf-exciting 3.5Prime voltage230v/400v 3.6Frequency50 hz 3.7Power factor0.8(lagging) 3.8Phase/wire3 phase 4 wires 3.9IsolationH Size:1850*730*1250 Weight:1000kg
20KW/25KVA Cummins Silent Diesel Generator Set Cummins Series Generator/Generators/Diesel Generator/Diesel Generator Set/Silent Generator/Silent Diesel Generator/Genset Power From 20KVA up to 1500KVA, with compacted structure and best configuration. OEM CUMMINS Powered Diesel Generator Sets with its high reliability, low use and maintenance cost win the loyalty of many customers in the field of Army, transportation engineering system and mine industries. Established in 1919, headquartered in Columbus, Indiana, (USA) Cummins Inc. Serves customers in more than 160 countries and territories through its network of 680 Company-owned and independent distributor locations and more than 5, 000 dealer locations. As the largest foreign engine investors of China, Cummins possess Chongqing Cummins Engine Co., Ltd (produce M, N, K series engine) and Dongfeng Cummins Engine Co., Ltd (produce B, C, L series engine ) and produce CUMMINS engines with globally uniform quality standards. Control Systems Standard control panel is the basic configure for normally operation and usage. The advantages of this panel are easy operation, aomprehensive function and reliable protection and so on. There are indicating gauges, lamps, transfer switches and emergency stop button, etc. The control panel wil stop the whole generator set and alarm as well when malfunction appears. LED Automatic Control Panel is a kind of intelligent controller with LED displaying the operating mode of the controller and the running state of the generator sets. It can configure the control procedure and protection parameter of the generator set, and completely satisfied the automatic controlling requirement of the generator sets for the user or factory. LCD Automatic Control Panel is the configuration for nobody on duty controlling generator sets. This kind of panel adopts module control system, with large LCD screen to show the menu. The module can receive output signal from ATS and realize automatic start and stop the generator sets. 1, DCEC/CCEC Cummins Diesel Engines 2, Stamford / Leroy Somer / Marthon Alternators 3, CE Approved 4, One Year Warranty General Data Sheet Cummins Generators 50HZ Genset Model Standby / Prime Power Engine Model No. of Cylinder Displacement (L) Oil Capacity (L) Coolant Capacity (L) Genset Size (mm) Weight (KG) KVA KW Cummins L W H HF20C 30/25 24/20 4B3.9-G2 4 3.9 11 17 1470 650 1145 650 HF30C 40/37.5 32/30 4BT3.9-G2 4 3.9 11 17 1685 650 1145 700 HF40C 62/50 50/40 4BTA3.9-G2 4 3.9 11 18 1800 670 1190 830 HF50C 70/62.5 56/50 4BTA3.9-G3 4 3.9 11 18 1900 670 1190 850 HF64C 90/80 72/64 6BT5.9-G2 6 5.9 16 29 2100 790 1320 1050 HF80C 110/100 88/80 6BT5.9-G2 6 5.9 16 29 2100 790 1400 1080 HF90C 125/113 100/90 6BTA5.9-G2 6 5.9 16 29 2200 790 1450 1150 HF108C 150/135 120/108 6BTAA5.9-G2 6 5.9 16 29 2400 840 1450 1200 HF128C 175/160 140/128 6CTA8.3-G2 6 5.9 16 30 2480 860 1450 1400 HF144C 200/180 160/144 6CTA8.3-G2 6 8.3 24 35 2480 860 1460 1650 HF160C 220/200 176/160 6CTAA8.3-G2 6 8.3 24 39 2700 950 1460 1650 HF180C 250/225 200/180 6LTAA8.9-G2 6 8.9 24 47 2700 960 1500 1800 HF200C 275/250 220/200 6LTAA8.9-G2 6 8.9 24 47 2700 960 1500 1900 HF220C 300/275 240/220 6LTAA8.9-G3 6 8.9 24 47 2700 960 1500 2050 HF280C 375/330 300/264 QSM11-G2 6 11 38 62 3110 1200 1745 2880 HF320C 450/400 360/320 NTAA855-G7A 6 14 37 65 3300 1250 1720 3050 HF360C 500/450 400/360 KTA19-G3 6 19 50 99 3310 1290 1720 3100 HF420C 575/525 460/420 KTA19-G4 6 19 50 99 3600 1290 1900 3750 HF500C 688/625 550/500 KTAA19-G6A 6 19 50 195 3800 1500 1980 4500 HF620C 850/775 680/620 KTA38-G2 12 38 135 265 3860 1600 2195 6000 HF720C 1000/900 800/720 KTA38-G2A 12 38 135 303 3860 1600 2195 7000 HF820C 1125/1025 900/820 KTA38-G5 12 38 135 309 5300 1950 2500 8500 HF1020C 1400/1275 1120/1020 KTA50-G3 16 50 177 349 5300 2150 2520 9950 HF1200C 1675/1500 1340/1200 KTA50-G8 16 50 204 349 5300 2200 2550 10500
Genset Main Performance Data Model:ZDCS20-A1 Rated Power:20KVA Power Factor:COSΦ=0.8 Rated Output Voltage:400V/230V Rated Current:27A Rated Speed:1500RPM Startup Control Mode:Electric Starting Fuel Consumption at 100% loading:208g/kw/h Noise (at 1m distance):98db(A) Regulating Rate Of Steady Voltage:â?¤Â±0.5% Regulating Rate Of Instantaneous Voltage:â?¤Â±15% Waving Rate Of Voltage:â?¤0.5% Waveform Distortion Degree Of Voltage:â?¤5% Time Of Steady Voltage:â?¤1.5 seconds Regulating Rate Of Steady Frequency:â?¤Â±2% Regulating Rate Of Instantaneous Frequency :â?¤Â±5% Time Of Steady Frequency:â?¤3 seconds Waving Rate Of Frequency:â?¤Â±0.5% Dimensions(LxWxH):1650x720x1200 mm Weight:700kg â??High efficient water cooled diesel engine. â??Radiator with pressure cap and drain point. â??Single bearing with brushless alternators (Class H, with AVR). â??Fully guarded engine-driven fan. â??Fully welded steel skid base with lifting holes and fork lift legs. â??Heavy duty rubber anti-vibration mountings. â??Integral fuel tank with filler cap and gauge (â?¤650kVA). â??Separate engine-driven battery charging alternator. â??12V or 24V maintenance free starter battery and connecting cables. â??Industrial silencer (15dBA reduction) supplied loose. â??Spin on oil and fuel filters and dry type air filter element. â??Auto start control system with LCD show. â??Battery charger provided. â?? Electric speed control â?? 24v starting batteries,maintennance-free type,connecting cables. â?? Equipped with CHINT MCCB;ABB in Option â?? Equipped with industrial silencer and flexible exhaust hose. â?? Main line 3P circuit breaker. â?? Radiator 40°C max, fans are driven by belt with safety guard. â?? Rigorous factory test wiring with IEC standard. â?? Design Comply to ISO8528/GB2820 â?? Absorber (Anti Instant Braking) â?? Wide range of optional extra features available. â?? User Manual, Packing List
Bcm1000-60 as below: Cummins engine:kta38-g2(original from uk) marathon alternator:mx-600-4 control system: uk deep sea dse7320 Open type size:4500 *1650 *2400 mm i unit in 1*20gp container Weight:7900kg
EA Genset supplies Cummins engine diesel generators sizes from 1 kVA to 3000 kVA Variety of Fuel Types
Genset Model----PCC275B Prime Rating (kw)-----200 Standby Rating (kw)---220 Rate voltage(V)---400 Rate current(A)----361 Power factor---0.8 Frequency(Hz)---50 Engine Engine Model----MTAA11-G2 Gross Engine output-Prime (kw)---224 Gross Engine output-Standby (kw)---246 Bore * stroke (mm)----125*147 Cylinders and structure----6 In line Displacement(Liter)---10.8 Compression Ratio----16.1:1 Intake way---Turbocharged/Air-Air intercooler Max intake resistance (KPa)---6.2 Air intake (m3/h)---947 Max exhaust back pressure (KPa)----10 Exhaust gas flow (m3/h)----2367 Exhaust temp (â??)-----510 Cooling way------Water Radiator & Fan Fan exhaust flow (m3/min)-----420 Coolant capacity (L)----55.4 Highest water temperature(â??)-----104 Minimum air opening to room (m2)-----2.1/1.4 Thermostat range (â??)----82-94 Max oil temperature (â??)---121 Lubrication system oil capacity (L)---36.7 Rate load fuel consumption(L/H)----51.6 Standard Governor-----Electronic Alternator Rated Voltage(V)-----400/230 Output Way----3 Phases, 4 wires Rated power factor----0.8 Exciter Brushless----Self-exciter Max voltage regulation---±1% Phase---3 Protection class---IP21-23 Insulation class---H Controller-- GC6110
New power-npc series diesel generator we provide can be warrant of its certified of origin. Especially, as oem factory we can keep perfect and reliable quality by the supports of original cummins enterprise. Rated voltage: 380v/220v Line way: 3 phases & 4 lines Frequency: 50hz Power factor: 0.8(lagging) We can also provide 60hz and other international standard requirements about diesel generator sets to comply with the demands of clients.
Cummins QSK60-G6 Diesel Generator Sets, Two (2) 2000 KW open skid mounted, V16 cylinder engine, turbocharged, After-cooled, Cummins High Pressure Injection (HPI) PT full authority electronic fuel system. Quantum series utilizes sophisticated electronics and premium engineering to provide outstanding performance levels, reliability and versatility for Standby, Prime and Continuous Power applications. 480 volt, 1800 rpm, 60 HZ, Year 2011, Well maintained in Excellent Condition.
Model 6btaa5.9-g2 Power of output/kva 137.5 Number of cylinder, bore, stroke(mm) 6-102x120 Displacement (l) 5.88 Oil capacity (l) 16 Type of governor Electronic Dimension(l, w, h) (mm) 2300*800*1500 Net weight (kg) 1100
Engine brand Cummins Alternator brand Stamford Engine model 4BTA3.9-G2 Alternator model XN50 Engine ouptout 66kw Alternator power 50kw Cylinder No. 4 Protection grade IP22 Cooling method water cooled Excitation mehtod brushless Start method electric starting Insulation grade H weight: 850kg dimensions:1760*710*1400mm
Rated power: 30kva-1650kva Engine: cummins Alternator: leroy somer / stamford / marathon/ Diesel engine: four stroke, water cooling, dierect spraying, 1500/1800rpm, the closed-end circular cooling with fan. The ac generator:phases:3 phases and 4 wires The rated voltage:400/230v(adjustable) The rated frequency:50hz/60hz(adjustable) The rated factor:0.8(lagging) Excitation:brushless insulation class:h Protection:ip22 or ip23 voltage adjustment: avr Standard export package
350kva, 50hz, 3phase, 220/380v, standby power, silent type. Cummins engine nta855-g1b with stamford alternator, deepsea controller dse7320, delixi circuit breaker Brilliant power, the headquaters is in china and western factory in spain, uk, is a market-oriented enterprise based on 10 years experience in the field of generator set, lighting tower and related accessories , whose power range from 8kva to 4000kva. As a new generation in the power generation industry, we fully supply generator set, lighting tower to our clients in accordance with market /customer demand for a variety of applications, such as residential, commercial, industrial, rental purposes. In order to supply reliable and excellent performance , brilliant adopts renowned engine from all over the world, covering deutz, perkins, cummins, doosan, mitsubishi, yanmar as well as trusted chinese engine. In consideration of stable voltage output, top-class alternator is our prior option, including leroysomer, stamford, meccalte etc, to be cost-effective , domestic alternator with reliable performance is available too. On the basis of market segmentation and product orientation, we are not only supply generator set, lighting tower to the market, but also focus on differential applications , which follow the idea of selling products as a consulter not just a manufacturer.
EAC 1000 Engine: CUMMINS Engine Model : KTA38-G2A Stand By kVA: 1000 Stand By kW : 800 Prime kVA: 909 Prime kW : 727 Rated Current : 1308 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2A Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 895 / 1199 Prime Power Hp 813 / 1089 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 202,3 Lt %75 LOAD 153,7 Lt %50 LOAD 103,1 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9350 Weight (Open) Kg 8200 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 890 Engine: CUMMINS Engine Model : KTA38-G2B Stand By kVA: 890 Stand By kW : 712 Prime kVA: 809 Prime kW : 647 Rated Current : 1165 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2B Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 789 / 1057 Prime Power Hp 711 / 953 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 176,9 Lt %75 LOAD 133,3 Lt %50 LOAD 91,3 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9300 Weight (Open) Kg 8150 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 825 Engine: CUMM�°NS Engine Model : KTA38-G2 Stand By kVA: 825 Stand By kW : 660 Prime kVA: 750 Prime kW : 600 Rated Current : 1080 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G2 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 38 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 731 / 980 Prime Power Hp 664 / 890 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 167 Lt %75 LOAD 128 Lt %50 LOAD 90 Frequency Hz Power kVA 825 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9250 Weight (Open) Kg 8100 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnot permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 790 Engine: CUMMINS Engine Model : KTA38-G1 Stand By kVA: 790 Stand By kW : 632 Prime kVA: 718 Prime kW : 574 Rated Current : 1033 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model KTA38-G1 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 701 / 953 Prime Power Hp 634 / 862 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 158 Lt %75 LOAD 122 Lt %50 LOAD 86 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9200 Weight (Open) Kg 8050 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 495 Engine: CUMMINS Engine Model : QSZ13-G3 Stand By kVA: 495 Stand By kW : 396 Prime kVA: 450 Prime kW : 360 Rated Current : 648 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternator - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMINS Engine Model QSZ13-G3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 17:01 Bore 130 Strok 163 Displacement L 13 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 40 Standby Power kw / Hp 470 /629 Prime Power kw / Hp 450 /603 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 60 Fuel Consumption (lt / h) L Full Load 101 L %75 LOAD 74,2 L %50 LOAD 49 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 4100 Weight (Open) Kg 3625 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 440 Engine: CUMMINS Engine Model : NTAA855-G7A Stand By kVA: 440 Stand By kW : 352 Prime kVA: 400 Prime kW : 320 Rated Current : 576 Engine - CUMM�°NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM�°NS Engine Model NTAA855-G7A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 14.0:1 Bore 140 Strok 152 Displacement L 14 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 38,6 Standby Power kw / Hp 407 / 545 Prime Power kw / Hp 370/ 500 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 60 Fuel Consumption (lt / h) L Full Load 89,2 L %75 LOAD 67,8 L %50 LOAD 47,5 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation �±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 3765 Weight (Open) Kg 3290 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 420 Engine: CUMMINS Engine Model : NTAA855-G7 Stand By kVA: 420 Stand By kW : 336 Prime kVA: 382 Prime kW : 306 Rated Current : 550 Engine - CUMMINS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat�¶r - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMINS Engine Model NTAA855-G7 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 14.0:1 Bore 140 Strok 152 Displacement L 14 Air Intake Turbocharged,Air-Air Cooled Speed (RPM) 1500 Oil Capacity L 39 Standby Power kw / Hp 377 / 505 Prime Power kw / Hp 343 / 460 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 55 Fuel Consumption (lt / h) L Full Load 89,2 L %75 LOAD 67,8 L %50 LOAD 47,5 Frequency Hz Power kVA 385 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation ±1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 3765 Weight (Open) Kg 3275 Width (Silent) Mm 1600 Length (Silent) Mm 4500 Height (Silent) Mm 2400 Fuel Tank Capacity L 650 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.