1.Thickness measurement using both Magnetic Method and Eddy Current Method to measure the non-magnetic coating on a magnetic metal substrate, or non-conductive coating on non-magnetic metal substrate. 2.Single-point or two-point method could be used to correct probe system deviation, in order to ensure the accuracy of the device in the process of measuring. 3.Fast automatic identification of iron and non-iron substrate. 4.Power voltage indicator. 5.Speaker beep while operating. 6.Power-off automatically when idle; manually power-off available. 7.Negative display function to ensure the accuracy of zero point calibration. 8.Ultra-low power consumption, less than 10 μA in standby mode. z
Looking for Ultrasonic Thickness Gauge, Contact India Tools & Instruments Co. backed by rich industry experience, the company is recognized as splendid Ultrasonic Thickness Gauge manufacturers, suppliers, and exporters based in India. Visit: http://www.india-tools.net/ultrasonic-thickness-gauge.html
India Tools & Instruments Co. is known for being the world famous Thickness Gauge Manufacturers. Thickness gauge is used to measure the thickness of the materials as to determine the tensile strength of the same. We are the highly acclaimed manufacturers for engineering the products with the high technology and best quality products. Call us now or leave your enquiries today to get the products delivered at your doorstep. Visit: http://www.india-tools.net/thickness-gauge.html
Product description The basic type coating thickness gauge ac-112 series have two types: type c ( integral type ), type cs ( separate type ); suitable for automotive, paint layer coating thickness measurement; integral type suitable for single-hand operation, large probe with large contact surface have better stability, users can get continuous, good repetitive and precise measurements. Separate type can provide several type probe, measure can be more flexibility. Product parameters Measuring range0~1250 um 0~50mil (other range may be specified) Resolution0.1 um (0~99.9um)/1 um (over 100um) Humidity:
LDT-L200 Ladle Lining Laser Thickness Gauge Overview LDT-L200 is a new generation of ladle lining thickness gauge launched by our company. The system equipment emits a pulsed laser beam to the lining surface of the ladle, and receives the returned laser light to measure its flight time. Then the system equipment calculates the distance between the equipment and the target point according to the transmission speed of the laser. During measurement, the user pushes the equipment to a certain position on the platform in front of the ladle, and the equipment can start to scan and measure the target area of the ladle after the equipment performs rapid self-positioning. The detection principle The measurement speed of LDT-L200 can reach up to 2,000,000 points per second, and each scan can obtain distance data of more than 1.5 million points. The actual surface curve of the entire ladle lining can be obtained by combining the measurement data of different positions. During the measurement, the laser head of the equipment rotates at a certain step angle to rapidly change the angle of the pulsed laser beam. Within 1 minute, the three-dimensional surface contour of the ladle lining can be formed, and the thickness information of the furnace lining can be obtained through coordinate conversion calculation. The measurement accuracy up to 2mm. In order to accurately calculate the thickness of the lining in the ladle, the measuring head of the laser thickness gauge is installed on the ladle repairing platform. By moving the swivel arm for hoisting, the laser scanning head is moved to the intersection position during measurement, and the relative position of the laser head to the ladle mouth will be calculated during installation. Through mathematical modeling, a complete 3D figure of the thickness of the entire ladle lining can be displayed after laser scanning The main components 1. Laser measuring head 2. Fixed laser thickness gauge host 3. Optical fiber communication 4. Cooling circulation system The technical indexes Laser reproducibility: 2mm Laser accuracy: 2mm Local fastest measurement time:
Product Code Product Description PRS-A0115 Thickness Gauge (Flakiness Index BS) STANDARDS : Thickness Gauge is used to determine if the aggregate particles are to be considered as flaky, i.e. their thickness is less than 0.6 of their nominal size. The aggregate to be classified is separated into seven sieve fractions from 6.3 to 63 mm, and each fraction is examined separately. Slot sizes are 4.9 x 30 mm, 7.2 x 40 mm, 10.2 x 50 mm, 14.4 x 60 mm, 19.7 x 80 mm, 26.3 x 90 mm and 33.9 x 100 mm. Dimensions 310x130x10 mm Weight (approx.) 0,4 kg
IPRE Coating Thickness Gauge PRCT110 Website: www.iprecn.com Features Integrated with magnetic-induction probe (F) and eddy current probe (N), switch to the suitable probe automatically according to the material to be measured Magnetic induction probe (F) is to measure the thickness of Non-magnetic coating on magnetic substrate Substrate: iron, steel�magnetic stainless steel (does not include non-magnetic stainless steel), etc. Coating: zinc, copper, chrome-tin, plastic powder, paint (does not include nickel), etc. Eddy current probe (N) is to measure the thickness of non-conductive coating on non-magnetic metal substrate Substrate: copper, aluminum, zinc, non-magnetic stainless steel, etc Coating: plastic powder, paint, anodizing film, etc Power off automatically, time can be preset according to your requirements Main Technical Specification Probe Type F N Measuring Principles Magnetic Induction Eddy Current Measuring Range 0�1250µm 0�1000µm Measuring Mode Single or continuous Calibration Mode Zero Calibration Accuracy Zero calibration(um) ±(3%H+1)um ±(3%H+1.5)um Two-point calibration(µm) ±[(1�3)%H+1]um ±[(1�3)%H+1.5]um Measuring Condition Min. radius of curvature(mm) convex 1.5 convex 3 Min. diameter of area(mm) Φ7 Φ5 Critical thickness of substrate(mm) 0.5 0.3 Dimensions in mm 52*25*110 Weight 200g Standard Delivey Main Unit 1 pc Calibration Block 1 pc Battery 2 pcs Manual 1 pc Packing list 1
Operating Principle:P-E (pulse-echo) with dual-crystal probes Measuring Range:0.03'' to 12'' in standard mode Storage:5 arrays are divided to store 500 thickness values Repeatability:0.001'' Display Resolution: 0.001inch Units:Inch or Millimeter Update Rate:4Hz Measuring Error: Low limit to 0.4'': +-0.004'' 0.4'' to high limit: +_ (1%H+0.1) mm Note: H is the actual thickness of the testing material Operating Time:Up to 200 hours with alkaline batteries (without backlight) Instrument Shut-off:AUTO OFF after 5 minutes of inactivity Power Requirements:Two 1.5V AA alkaline batteries (Warning with low battery voltage) Operating Temperature:14°F to 122°F, 4°F in special requirements
Canneed MBT-200 Hall Effect Thickness Gauge (Magnetic Bottle Thickness Gauge)¡± is a refined portable thickness gauge. It is used to measure the thickness of nonmagnetic material, such as plastic, glass, synthetics, aluminum and titanium, etc. The measurement accuracy is undistorted by the samples shapes. MBT-200 is based on the theory of Hall Effect. For test, place the steel ball on one side of the sample and the probe on the other side. The Hall Effect sensor on the probe measures the distance from the probe tip to the steel ball. The calculator will display the real thickness readings. Attributes: * Adopted non-destructive test method. With quick measurement for spot thickness on area where accurate measurement of corners, small radii, or complex shapes are required * Display the real time thickness readings and automatically capture the minimum thickness * A standard instrument in plastic packaging industry * Rapid measurement, up to 16 times per second * Accuracy: 1% * It stores 95,000 thickness readings as the internal data record. Technical Data: Steel Ball Dia. 1/16 (1.59mm) 1/8 (3.18mm) 3/16 (4.76mm) Thickness Range (Standard Probe) .0001-.0900 (.001-2.590mm) .0001-.0900 (.001-4.570mm) .0001-.0900 (.001-6.350mm) Calibration Graduation (Accuracy) 3%* 2%* 1%* The accuracy to be subject to the thickness range. Please refer to the manual for detailed specifications: Scanning Speed : up to 16 times (Optional) Minimum Mode : rapid search and minimum thickness display Resolution : 0.01 mm or 0.001 mm (0.001 or 0.0001 ) Display : LCD display, can display the real time reading, minimum reading, alarm status and data document information at the same time. Data Recorder : It stores, reviews, eliminates and transfers 95,000 thickness readings and documents in numeric identifying code. Data Output : RS-232 serial port On-site Report: : Minimum value, maximum value, SD Calibration : Two-point standard calibration, or multi-calibration up to 5 reference points Deviation Mode : Display the difference between the actual thickness and the pre-set reference thickness Alarm Mode : Programmable, vocal and indication-visible high and low alarm setting points Power : 100/120/220/240 VAC, 48-62 Hz Battery : Rechargeable Nickel-Cadmium battery. According to the working status of background light, it can last for 8-16 hours. Charging time is 2 hours. Metric/Imperial Unit : Inch or mm for option Language : English Working Temperature : 0 - +50¡æ Dimension : 9.375*5.45*1.5 (238*138*38mm) N.W. : 3.2 kg Standard Configuration: MBT-200 Hall Effect Thickness Gauge includes: * Standard probe * Probe stand * Probe cable * User manual * Nickel-made rechargeable battery * External power supply and charger * Steel ball and calibration set, including Steel ball (with diameters of 1/16 , 1/8 , 3/16 ) Calibration block: 0.010 /0.25 mm, 0.04 /1 mm, 0.160 /4 mm (If pre-test sample is over 0.160 /4 mm, accessories are optional by order.).
Spectral Confocal Displacement Sensor The spectral confocal displacement sensor can realize precise measurement of distance, thickness of transparent objects and three-dimensional object morphology features. The instrument has high measurement accuracy, small size, simple operation and convenient to carry. It is widely used in semiconductors, photovoltaics, electronic components, automobiles, glass panels, logistics, food and other fields. The spectral confocal displacement sensor is mainly composed of measuring head, controller and optical fiber. A specific color-coded lens is used to generate axial dispersion of the white light, and the reflected signal of the measured workpiece is analyzed by the spectrometer to analyze the confocal light wave signal. Finally, the measured displacement of the workpiece is calculated by the wavelength and displacement conversion curve. Features 1. High stability; 2. Applicable to measurement of various morphology features; 3. The equipment is lightweight and compact , easy to carry and integrate into automated measurement system ; 4. Simple operation and high measurement accuracy; Technical parameters 1) Measuring range: ±3mm (displacement) , 0.5-2mm (glass thickness) 2) Working distance: 55mm 3) Spot size: 10m 4) Linearity: ±1m 5) Resolution: 0.05 m 6) Maximum inclination angle: ±10 7) Probe size: 33*75mm; 8) Probe weight: 150g
Product Description AMITTARI Standard Type Coating Thickness Gauge AC-112 Series have 2 types: Type A ( Integral Type ), Type AS ( Separate Type). Integral Type suitable for single-hand operation, large probe with large contact surface have better stability, users can get continuous, good repetitive and precise measurements. Separate Type can provide several type probe, measure can bemore flexibility. Product Parameters Measuring Range 0~1250 um 0~50mil (other range may be specified) Resolution 0.1 um (0~99.9um)/1 um (over 100um) Accuracy: 1~3%n or 2.5 um or 0.1mil (Whichever is the greater) Product Accessories Standard Accessories Main Unit Calibration Foils Substrate ( Iron ) Substrate ( Aluminium ) Carrying Case Operation Manual Optional Accessories USB data output Bluetooth data output Portable platstic case
YUSHI INSTRUMENTSWe Are Manufacturer 20 years NDT experience,ISO, CE & RoHS certificated, this is how we keep superior quality and competitive offers for global valued customers This instrument can be widely used in the fields such as manufacturing, metal processing, chemistry and business inspecting for measuring the thickness of all sorts of materials where ultrasonic wave can spread through with a constant speed and get the reflection from the back side Probes/Transducers Option: PT-08/04/06/12GT-12ZT-12TC110/210/705 Display Type:2.4'' color OLED, 320�240 pixels, contrast 10,000:1 Operating Principle:Pulse echo with dual elemet transducers Measuring Range:0.025 to 20.00 (depends on material, probe and surface condition) Measuring Resolution:0.001 or 0.01 Units:Inch or Millimeter Gain:Low, Medium or High for varying test conditions Display Mode:Normal, Minimum/Maximum capture, DIFF/RR% V-Path Correction:Automatic Refresh Rate: 4Hz, 8Hz or 16Hz Material Velocity Range:0.0197 to 0.3939 in/μs Languages:English, Chinese, Japanese, French etc Alarm Settings:Minimum and Maximum alarms. Range of 0.010'' to 20.00. Dynamic waveform color change on alarm Operating Time:Approximately 40 hours with two AA batteries Instrument Shut-off:ALWAYS ON or AUTO OFF after 5, 10, 20 minutes of inactivity Operating Temperature:14°F to 122°F Size:6 � 3 � 1.5 (H � W � D) Weight:280g including batteries Battery and Couplant are Prohibited Goods by Air Shipping by DHL taking 3-5 days Whats in the BOX? 1*Main Unit, 1*Probe, 1 * Carrying Case, 1* User Manual
Ready to measure no calibration adjustment required for most applications High contrast segment LCD diplay Flexible Japanese cable, resistant to break Precision measurement Standard CmView communication software Measuring Principle Magnetic Method (Fe): Measuring the thickness of non- magnetic coatings on steel, iron and other ferromagnetic metal substrates, e.g. painting, varieties of anti-corrosion coating, powder spraying, plastic, rubber, synthetic material, phosphate coating, chromium, zinc, Aluminum, tin and cadmium, etc. Features Display: High Contrast Segment Liquid Crystal Display(LED Backlight) Measuring Range: 0 TO 10000μm Auto Power-off: Auto off after 3 minutes of inactivity Calibration Method: Zero calibration, One-Point and Two-point calibration Power Requirements: 2 AA size batteries, low-voltage indication function
Specifications Display: 4 digits LCD, backlit Range: 0~1250 ¬ªm/0~50mil (other ranges can be specified ) Min.radius workpiece: F: Convex 1.5mm/Concave 25mm N: Convex 3mm/ Concave 50mm Min. measuring area: 6mm Min.Sample thickness : 0.3mm Resolution: 0.1 ¬ªm (0~99.9¬ªm); 1 ¬ªm (over 100¬ªm) Accuracy: f+1~3%n or 2.5 ¬ªm or 0.1mil (Whichever is the greater) Bttery Indicator: Low batter indicator. PC interface: with RS-232C interface Power supply: 2x1.5 AAA(UM-4) battery Operating condition: Temp. 0~50f¦ . Humidity
Bronze Sleeve Packed Water Level Gauge Rating : Max. BOP 250 PSIG (17.24 Bar) at 435 F (225 C) Material : Bronze Description : Consisting of Steam Arm, Water Arm, Drain Cock, Left & Right Hand Type Ends : Screwed Specials : IBR Item Code : BM000057, BM000058 Size : 15mm Notes : Available Valve Size : 15mm to 20mm
Bronze Sleeve Packed Water Level Gauge Rating : Max. BOP 250 PSIG (17.24 Bar) at 435 F (225 C) Material : Bronze Description : Consisting of Steam Arm, Water Arm, Drain Cock, Left & Right Hand Type Ends : Flanged Specials : IBR Item Code : BM000055, BM000056 Size : 15mm Notes : Available Valve Size : 15mm to 20mm
Richter hardness tester, ultrasonic thickness gauge, coating thickness gauge.
12 x 2000 Premium Foodservice Film with Slide Cutter This 12â?³x 2000â?²durable plastic wrap is a must-have in any commercial kitchen or food service operation. Versatile and easy to use, this plastic wrap can be used for a variety of applications. Great for covering and wrapping food items for food prep and storage, this wrap is perfect for a variety of kitchen uses. Itâ??s the ideal wrap for food service and institutional use, such as in cafeterias, restaurants, and fast food establishments. Additional information Weight 6.19 lbs Dimensions 13 x 5 x5 in Type Wrap Material PVC Quantity 1/each Color Clear Length 2,000 Feet Width 12 Inches