The disposable virus sampling tube/Virus Transport Medium(VTM) is suitable for nucleic acid extraction of SARS-CoV-2 virus, various influenza viruses, avian influenza viruses, rubella, swine fever and other virus samples. The disposable virus sampling tube/Virus Transport Medium(VTM) is suitable for nucleic acid extraction of SARS-CoV-2 virus, various influenza viruses, avian influenza viruses, rubella, swine fever and other virus samples. It is also suitable for the collection and transportation of specimens of Chlamydia, Mycoplasma, and Mycoplasma Arthroplasma. Samples are usually collected from the mouth, throat, nasal cavity, and anus. Sampling tube: The tube body and tube cover are made of polypropylene, which will not deform at high temperature and high pressure (121C, 15min), and will not become brittle at low temperature (196C). Resistant to static extrusion and dynamic impact. The bottom tapered design is resistant to centrifugation and vibration. Built-in sample preservation solution is used for sample preservation to prevent leakage. Sample preservation solution: Functioned with virus lysis solution and virus nucleic acid preservation solution. The virus lysate realizes the inactivation of the virus in the sample and reduces the risk of secondary infection. The unique protection system can prevent nucleic acid from being degraded and improve the accuracy of downstream detection. The sample has a wide adaptability and can be used for the collection, preservation and transportation of various swabs. Sampling swabs: sampling swabs are flocking sampling heads, which are non-toxic to cells and viruses, and do not contain RNase, which can greatly increase the collection and release of virus samples , ensure the accuracy of PCR detection results. The plastic rod is made of ABS, with a unique molded breaking point design, and there is no tiny debris during the breaking process. Features: 1.More collection and release:nylon flocked swabs provide optimum specimen collection because of their ability to collect more specimen at the collection site and to more rapidly release the entire samples specime 2. High safety factor: it can lyse pathogens, inactivate viruses, and reduce the risk of secondary infection. 3. Stable nucleic acid: a unique protection system that can prevent nucleic acid from being degraded and improve the accuracy of downstream detection. 4. Wide sample adaptability: it can be used for the collection, preservation and transportation of various swabs,Including oral swabs, throat swabs, nasal swabs, vaginal swabs and so on.
St-8612pc materials tensile test machine Standard: in accordance with GB 16491, GB/T 2951.1, UL1581, IEC 60811-1-1 standards Technical parameters: 1. Induction method: high precision load cell (sensor) 2. Capacity (optional): 100 / 200 / 500 / 1000 / 2000 / 5000 kgf 3. Unit (switchable): KGF, N, LBF 4. Can meet or surpass of reading: 0.4~100% 5. Load resolution: 1/200000 the same stage and the some resolution during the whole test 6. Class: 1 level 7. Load accuracy: 1% 8. Testing range: 800mm (exclude the grips) 9. Availability width: 340mm 10. Displacement resolution: 0.01/0.001mm 11. Normal non-metal large deformation test instrument: 1 set Metal deformation test instrument (elongation meter): normal distance 10/25/50/100mm optional 12. System constitution: above windows xp operating system, t2006 specific control software and a4 color print function for tester, indicator: computer system software and print function 13. Test speed: 1) metal specimen 0.01~250mm/min, 2) non-metal specimen: 0.01~500mm/min 14. Method of speed: keyboard input 15. High security: restrict protection 16. Over load: protect automatically when 10% of max exceeds. 17. Motor: ac servo motor 18. Tensile grips: select according to users products requirement 19. Power source: ac 220v10%, 50hz / 5a 20. Weight: approx. 280kg Polywood case
Functions as follow: 1. The testing machine is equipped with 100KN axial actuator, which can complete the uniaxial tensile, compression and fatigue testing of materials. 2. The machine is configurate with high temperature heating box, which can complete the fatigue testing uner 1100 . 3. Adopt of imported load cell, displacement and deform extensometer, which would control the data of testing force, confining pressure, specimens deformation automatically and precisely. Such as: a) constant stress, constant displacement, constant deformation. b) speed of constant stress, constant displacement, constant deformation. c) rate control of stress, displacement, deformation. d) loading and unloading in circulation. 4. The testing machine adopts high performance electro-hydraulic servo proportional valve set with wide speed and digital controlling with full digital closed-loop speed regulation control system, smoothly (no impact) conversion among force (stress), displacement and deformation (strain). 5. Safety protections: a) electric system: over voltage, over current, over heating. b) measuring and c pressure, oil temp, oil-way blocking. d) high temp system: ultralimit of high temp e) deformation and time pre-setting, limit of deform. f) protection of specimens rupture 6.The software of testing is working under windows with strong data processing, automatically save, display and printing. Standards as follow, GB/T2611-2007 General Technical Requirements for Testing Machine JJG 139-1999 Tension,Pressure and Universal Testing Machine GB/T2282010 Metal Tensile Test GB/T3075-82 Standard Test Method for Axial Fatigue of Metals GB/T2039-80 Test Method for Tensile Creep of Metals GB/T16826-2008 Electro-hydraulic Servo Universal Testing Machine JB/T9397-2002 Technical Condition of Tensile and Compression Fatigue Machine GB/T228.1-2010 and GB4338-2006-T Testing Methods of Metals Technical spec: 1.Actuator: imported HANCHEN dynamic servo actuator in Germany. Max static loading forceï¼?100KN Max dynamic loading forceï¼?100KN loading frequencyï¼?0.1Hzï½?100Hz orï¼?0.1-30HZï¼? Speed of flexï¼?0ï½?200mm/s Dynamic performanceï¼?loadï¼?±100kNï¼?Ã?amplitudeï¼?±0.1mmï¼?Ã?frequency(100Hz) Accuracy of loadï¼?±0.1%FS Accuracy of displacementï¼?±0.5%FS 2.TEMP of heating furnaceï¼?1100ï¼?accuracy : ±5 3. Testing specimens Specimens plateï¼?0ï½?10mm Round rod specimensï¼?dia. :0ï½?Ï?30mm High tempï¼?connect to M20 of high temp with threaded 4.Oil source systemï¼? Powerï¼? AC380V 50HZ about 35KW Flowï¼?57L/Min Pressureï¼?rated pressure: 25MPa 5.Sensorï¼? Load cellï¼?INTERFACE1032,range is 125KN,accuracy is ±0.04%FS
Features: Chassis: Nylon composite construction Drive: Four wheel with lightweight extruded aluminum shaft Radio: Traxxas TQ 2.4GHz High Output Traxxas Link with mini receiver Electronic Speed Control: Traxxas Velineon VXL 3S Motor: Traxxas Velineon 3500 with ultra high temperature Neodymium magnets and high speed ball bearings Spur Gear: 54 tooth, 0.8 module 32 pitch Pinion Gear: 13 tooth Battery: Traxxas Power Cell 8.4V 3000mAh 7-cell with high-current connector Battery Charger: Body: Painted and trimmed Bumpers: Front and rear, composite construction Shocks: Traxxas Ultra oil filled with high-volume body, silicone bladders, dual X-ring seals and progrssive springs Suspension: C-hub design Transmission: Ball bearing equipped with adjustable Torque-Control slipper clutch with finned aluminum alloy pressure plates Differentials: Revo-spec sealed silicone filled planetary gear type Ball Bearings: Rubber sealed Caster: Adjustable caster/toe-in refers to the angle of the front suspension when viewed from the side of the car in relation to the chassis Camber: Adjustable, camber refers to the angle of the tops of the tires from vertical when viewed from front or behind vehicle Tires: Mud-Terrain, with foam inserts 1.7" (43mm) wide, 4.3" (109mm) diameter Wheels: Beadlock style split spoke with chrome center and color molded outer rim to simulate beadlock, 12mm hex Steering: Dual bellcrank pivoting on rubber sealed bearings with integrated cam-type servo saver, waterproof digital high- torque (125 oz-in) servo. INCLUDES: Traxxas Slash 4X4 Short Course Race Truck with 2.4GHz radio system, brushless ESC and motor, body, 7-cell 3000mAh NiMH battery, AC powered charger, decals and illustrated instruction manual.
Product Description Insulated Copper Tube is mainly used for Installation of Air Conditioner. The Insulated Copper Tube is usually supplied by roll as per ASTM B280 standard, AS 1571 standard and EN 12735 standard. Our Insulated Copper Tube is R22, R407C, R410A, R404A, and R507C compliant. Product Feature The insulation is a double layered structure made of cross linked foam polyethylene with closed cells. The insulation tube is extruded to ensure close tube contact to enhance dew point proofing properties. The insulation is covered with embossed polyethylene film to prevent the foam creasing. The insulation tube is good for Anti-UV, heat resistance, low water absorption. Product Specification / Models Pair Coil size: 1/4 inch +1/2 inch, 1/4 inch +3/8 inch, 3/8 inch +5/8 inch, 3/8 inch +3/4 inchú¼ 1/2 inch +5/8 inch, 1/2 inch +3/4 inch Single Coil size: 1/4 inch, 3/8 inch, 1/2 inch, 5/8 inch, 3/4 inch Length: 3m, 5m, 6m, 7.5m, 15m, 18m, 20m, 25m and 30m Application ISO 9001 Other Information Supply Ability: 200MT/month Carton Box
FOR COLLECTION AND TRANSPORT OF SAMPLESFOR NUCLEIC ACID AMPLIFICATION TESTS Intended use: VIROSWAB/TRANSFER is a transport system used for the collection and transport of cells from clinical samples or from the environment, for isolation of nucleic acids that will be used in nucleic acid amplification tests. Summary and explanation of the test: Amplification of nucleic acids isolated of the cells obtained from clinical samples or from the environment by methods like polymerase chain reaction (PCR) is widely used for various purposes like detection of infectious agents, identification of their genotypes, identification of DNA sequences that lead to genetic diseases, drug resistance, etc. The sensitivity of these methods is very much dependant on the appropriate collection and transport of the samples. VIROSWAP/TRANSFER is a kit prepared to enable this. VIROSWAP/TRANSFER is made up of two parts: Sterile dacron swab in a plastic package for collecting the sample and sterile transport medium in a crack-proof plastic tube. Samples obtained by the dacron swab is put in the transport medium. Specimens like a biopsy, scrapings, discharge can directly be put into the medium. Limitations: RNA molecules are very susceptible to nuclease digestion that may be coming from degrading cells. If amplification is intended to be done using RNA molecules as a template, it is recommended to transport the samples in an icebox and isolate nucleic acids within 4 hours. Principles of the procedure: VIROSWAB/TRANSFER is designed in a way to enable easy collection and appropriate transport of the samples. Polycarbonate tubes will not crack as glass tubes when the samples are frozen to preserve for an extended period of time. On the other hand the glass like transparent structure makes it easy to visualize and manipulate the samples. Dacron swab is kept dry; after collecting the sample the shaft of the swab is broken and the swab is placed into the tube containing the transport medium. The shaft of the swab is made from special plastic to enable easy breaking. The transport medium contains tris which keeps the pH around 8.0, which is suitable for nucleic acid preservation. Samples may contain nucleases (DNAse and RNAse) which will digest free nucleic acids and prevent their amplification. These enzymes require Mg++ as their co-factor to be functional. EDTA that is included in the transport medium strongly binds Mg++ and thus inhibits nucleases and preserve nucleic acids. Ingredients: Sterile dacron swab in a plastic package. Nucleic acid transport medium (20mM Tris (pH 8.0), 2mM EDTA) 3ml in plastic tube.
Types: PMMA Sheet, PMMA Plate, Extruded Acrylic Sheet, Cast Acrylic, Cast PMMA Sheet, Frosted Satin Acrylic Main character: 1,Acrylic sheet is the best polymer transparent material, transmittance is 93%. Commonly known as plastic crystals. 2,High degree of mechanical The higher strength and impact resistance of acrylic sheet are 7-18 times higher than ordinary glass. 3,Light in weight The density of acrylic sheet is 1.19-1.20 g / cm¦ , and the same size of the material, its weight is only half of the ordinary glass. 4,Easy processing Acrylic can be used not only for cutting lathe, drilling machine for drilling, and can use acetone, chloroform and other adhesive devices into a variety of shapes and glass products. But also use blow molding, injection, extrusion and other methods of plastic molding process to the aircraft canopy. Application: Acrylic sheet are widely used for engraving sheets, advertisement sheets, instruments, parts of instrument, lamps, decorations, airplanes, automobile fittings, medical appliances, work of arts, insulation materials for electrical appliances, specimen, sign boards and various articles for light industry, culture, education and livelihood. Strong point: 1. Light transmission 92% is higher than the normal glass 91%.Surface is crystal clear, is enjoyed fame of THE QUEEN OF THE PLASTIC 2. Fine mechanical performance, it is suitable to use many performance way to make various sculpts. 3. Good resistant to Acid and corrosion, the surface is suitable to be printed. 4. Not easily fragile, the hardness is similar as copper or aluminum. 5. Good weather resistant, it is suitable to be used in outdoor of cold or hot region. The heat softening point is about 100 Degree. 6. Non-toxic, no odor, it can be used as container of food and medicine. Maintenance: 1, Temperature: the product will be softening when the temperature exceed 100 Degree, so it should avoid to use in the temperature of above 100 Degree. 2, Scratch: The surface of hardness of the PMMA sheet is similar as Aluminum, so the surface protection is necessary, if surface scratch happened, it should use the abrasive which brass used to polish it. 3, Clean: For keeping the surface clear ,when cleaning the surface, it should used the soft cloth with the suds of concentration 1% to clean it.
Zinc Coated Gabion Box These are manufactured from mechanically woven double twisted hexagonal wire mesh using Heavily Galvanized steel wire. The edges of the mesh are reinforced with a thicker wire called the selvedge wire to strengthen them and to facilitate construction. Gabions can be divided into cells by fitting diaphragms which reinforce the structure and make installation easier. Zinc + PVC Coated Gabion Box In case of marine or highly corrosive environment, an additional protection is provided by extruding a 0.5mm to 0.8mm thick PVC coating over the heavily galvanized wire. PVC coating is done on the galvanized wire prior to manufacturing of the gabion mesh. Advantages: 1.Stone filling is characterized by porosity that enables water to flow and doesnt create hydraulic pressure on the panels of gabion structures, it has drainage function. 2.Gabions are able to deform while still retaining their integrity, they adapt themselves to terrain where the concrete structures may crack and fail, they are suitable for unstable subgrades. 3.The high resistance and durability is secured by outstanding features of steel wire, its surface treatment by heavy galvanization or PVC coating and by the quality of stone filling. During the lifetime the pores are filled up with alluvia and the whole structure is grown through by vegetation what increases its strength and therefore is able to resist against great pressures. 4.Gabion baskets are made from double twisted, hexagonal woven wire mesh. The wire used to manufacture the gabion baskets is fabricated from high quality tensile, heavily galvanized steel, which is also available with an extruded PVC coating for additional corrosion protection, when required by the application. The double twist of the woven wire mesh provides integrity, strength and continuity to the structure by adding a non-raveling effect that prevents any accidental damage from spreading. Gabion application: Gabion baskets come in a variety of sizes and are best suited for gravity retaining walls, mechanically stabilized soil retaining structures, stream,bank protection, slope paving, outfall structures, weirs, etc Packing & Delivery: Packing Details: In pallet or in bundle, as buyer's requirement. Delivery Details: 5-10 Days after received the deposit by TT, according to buyer's quantity.
Ag+(Silver Ion) Features :1) Our products are not coated with silver ion(Ag+) catalyst material on the film surface. The resin of the film fabric is made by adding an ion(Ag+) catalyst and extruding the fabric. As a result, this is uniformly distributed with ion (Ag+) particles, and the antibacterial action is semi-permanent. 2) The fact that silver is harmless to the human body is well known, so it is familiar to people and is this basic research on Korea is well done. Silver ion(Ag+) catalyst, paying attention to the sterilization and antibacterial function of silver while looking for eco-friendly materials We're starting to develop technology. 3) Silver is chemically equivalent to mercury, nickel and chromium in heavy metals. However, it is special that it does not show any toxicity to the human body. 4) Silver ions have an adverse effect on cell metabolism and inhibits growth of bacteria and fungi when exposed to bacteria, fungi and viruses, thereby negating growth. 5) Silver is a metal used to treat medical conditions for more than 100 years due to its antibacterial and anti-viral abilities. 6) The simplification of the work process has enabled reasonable prices. 7) Semi-permanent anti-bacterial and anti-viral activities :it keeps you safe from -Contact infection - Direct contact propagation: hand-borne transmission - Indirect contact propagation: Infection by environment such as contaminated equipment or food - Countermeasures: Hand sanitizer (limit of sustainability) or Ag+ antibacterial film (anti-permanent) : Development of silver ion material technology that increases antibacterial efficacy by "removing 99.9% per hour" : We can use it subway straps, shopping cart hand grip , door handle strap, gas station , restaurant table, computer and mobile phone screen. etc
GST-01 Gel Strength Tester Significance of Gel Strength Testing Gel strength stands as a pivotal quality parameter across diverse industries, particularly in sectors like food production. Notably, in the realm of surimi processing, gel strength serves as a decisive factor governing the texture and excellence of surimi-derived products such as imitation crab meat. This metric significantly influences the mouthfeel, solidity, and overall sensory experience of the product. Understanding Gel Strength gcm The evaluation of gel strength is a procedural necessity, especially within food sectors like surimi processing. At its core, the gel strength test is aimed at scrutinizing the texture and caliber of gels, predominantly within industries reliant on gel-based products. Purpose: The gel strength assessment gauges a gel's capacity to endure deformation when subjected to an external force. This evaluation method is frequently employed to ascertain the texture and uniformity of gels, particularly those formed from proteins present in surimi (a paste derived from fish or meat). Principle: During the test, a punch probe, possessing specific dimensions, compresses the surface of a gel specimen at a constant rate of deformation until puncture occurs. Typically, a speed of 60mm/min and a probe diameter of �?5mm are utilized. Gel strength is derived from force multiplied by distance, thus denoted in "gcm." Technical Features of GST-01 Gel Strength Tester The GST-01 Gel Strength Tester boasts industrial-grade stability facilitated by PLC control, alongside intuitive HMI touch screen operation. Key Features: - Equipped with a 7-inch HMI touch screen, ensuring user-friendly navigation. - Incorporates a precision ball lead screw mechanism for meticulous speed and displacement control. - Custom-designed program offers flexibility in executing gel strength tests. - Multiple fixtures enable diverse texture analyses. - Safety prioritized with features like travel limit protection, automatic returning, and load cell protection cover. - Offers a range of test items including weight, peak, and distance measurements. - Features a dot matrix microprinter for comprehensive documentation. - Optional RS 232 port and professional software facilitate advanced data management. Test Items Covered: - WEIGHT: Measures distance at a specified load. - PEAK: Evaluates gel strength. - DISTANCE: Measures load at a specific distance. Main Parameters Test Range: 0-50N (or as required) Stroke: 110mm (without probe) Test Speed: 1~100mm/min Displacement Accuracy: 0.01mm Accuracy: 0.5% F.S. Control: PLC and human machine interface Output: Screen, Microprinter, RS232(optional)
Serum is one of the main specimens tested in clinical biochemical and immunological tests. At present, the methods of obtaining serum samples in medical institutions are mainly obtained by centrifugation after collecting venous blood after the blood is completely coagulated. Under normal circumstances, it takes more than 60 minutes for an isolated blood sample to completely coagulate, or even not coagulate, which is difficult to meet the needs of rapid laboratory testing. Therefore, shortening the coagulation process and quickly separating serum samples are important factors to improve the efficiency of laboratory medicine. The accelerator was born from this. In vacuum blood collection tubes containing coagulant, fibrin precipitated filaments and lumps sometimes appear, which is caused by the unstandardized use of coagulation blood collection tubes. Choosing a coagulant with too fast coagulation speed in the preparation of vacuum blood collection tubes will cause fibrin to shrink too fast and fragile red blood cells will easily fragment and cause mild hemolysis. Generally, the precipitation of fibrin has the following reasons: Use procoagulant blood collection tube or separation gel to promote coagulation blood collection tube. To make the coagulant evenly distributed in the blood, it must be slightly inverted and mixed 4-5 times to make the center of the blood collection tube and the surrounding blood coagulate at the same time. If the blood is not completely coagulated and then centrifuged, it can cause the precipitation of fibrin. The upper part of the serum appeared jelly-like and fragmented, mixed with the blood. Fibrin filaments are caused by the fact that fibrin has not yet fully contracted. Secondly, when the blood collection tube company prepared the coagulant blood collection tube, the coagulant was not sprayed enough or the prepared water-soluble coagulant was not used up on the same day, and continued use the next day, which resulted in the decrease of the coagulant effectiveness. The fibrinogen in the blood is gradually transformed into insoluble fibrin under the action of the coagulant. If the coagulant dose is insufficient or fails to extend the clotting time, centrifugation can lead to the precipitation of fibrin. Deshengâ??s main products are blood collection tube additives. It has 15 years of R&D and production experience. Coagulant, high-efficiency coagulant powder, heparin sodium, heparin lithium, and serum separation gel are our main products for so many years. With high quality, stable performance and guaranteed after-sales service, everyone is welcome to come to exchange and cooperate.
Product Code Product Description PRS-KA0552 Manual (Hand Operated) Pressure System for Lateral Pressure in Hoek Triaxial Cell PRS-B4231 2000 kN Automatic Compression Testing Machine, 220-240 V 50-60 Hz PRS-KA0555 Hoek Triaxial Cell BX, Ã? 42,04 mm dia. PRS-KA0557 Hoek Triaxial Cell NX, Ã? 54,74 mm dia. PRS-KA0560 Hoek Triaxial Cell HQ, Ã? 63,5 mm dia. PRS-KA0568 Compression Jig Assembly for Rock Core Specimens PRSGE-3800 Hydraulic Hand Pump, 700 bar. PRSC-0210 High Precision Pressure Transducer and Electronics STANDARDS : EN 1926, 14580; ASTM D2664, D2938, D3148, D5407 The manual pressure system is used for maintaining the constant lateral pressure in the Hoek triaxial cells and consists of a hydrolic hand pump with oil reservoir (PRSGE-3800), a precision LPI digital readout unit (PRS-B4920), a pressure transducer (PRSGM-0110) and a 3 m long flexible hose with quick release coupling. The manuel pressure system is used with any Hoek triaxial cell and 2000 kN Automatic Compression Testing Machine (PRS-B4231) for the triaxial tests. Other type of PARSROS compression testing machine (respect to the capacity) can be used instead of PRS-B4231. Technical Specifications LateralPressure Equipment PRS-B4231 Max. Working Pressure 700 bar (70 MPa) 410 bar Dimensions 1050x500x300 mm 800x500x970 mm Weigth (approx.) 20 kg 795 kg
Product Code Product Description PRS-KA0550 Automatic Pressure System for Lateral Pressure in Hoek Triaxial Cell, 220-240 V 50-60 Hz PRS-KA0550/110 Automatic Pressure System for Lateral Pressure in Hoek Triaxial Cell, 110 V 60 Hz PRS-B4231 2000 kN Automatic Compression Testing Machine, 220-240 V 50-60 Hz PRS-KA0555 Hoek Triaxial Cell BX, Ã? 42,04 mm dia. PRS-KA0557 Hoek Triaxial Cell NX, Ã? 54,74 mm dia. PRS-KA0560 Hoek Triaxial Cell HQ, Ã? 63,5 mm dia. PRS-KA0568 Compression Jig Assembly for Rock Core Specimens PRS-B0210 High Precision Pressure Transducer and Electronics STANDARDS : EN 1926, 14580; ASTM D2664, D2938, D3148, D5407 The PRS-KA0550 Automatic Pressure System is used to apply lateral pressure in the Hoek Cell during the triaxial testing of rock specimens. The power pack is equipped with a proportional valve to provide a sensitive control of the loading rate and to maintain a constant confining pressure to within 0.1 bar. Pressure is controlled by using the PID closed loop controlled electronics. The user can define the set lateral pressure and display the lateral pressure through the control and readout unit. Control Uni is designed to control the power pack and processing of data from pressure transducers which is fitted to the power pack. All the operations of Control Unit are controlled from the front panel consisting of a 800x480 pixel 65535 color resistive touch screen display and function keys 4 analogue channels are provided for loadcells, pressure transducers or displacement transducers. It has easy to use menu options. It displays all menu option listings simultaneously, allowing the operator to access the required option in a seemless manner to activate the option or enter a numeric value to set the test parameters. Its specimen setting sub-menu lists different specimen types including but not limited to cube, cylinder, block, beam, beam double upper bearers, cube splitting tensile, cylinder splitting tensile, paving block splitting tensile and kerb flexure. The Control Unit digital graphic display is able to draw real-time "Load vs. Time" or "Stress vs. Time" graphics. The Control unit offers many addition unique features. You can save more than 10000 test results in its internal memory. Storage capacity can be increased up to 32 GB using SD memory cards or USB disk-drives. Control unit has support for various off-the-shelf USB printers, supporting both inkjet and laser printers. Control unit is equipped with a built-in internal camera which can save real-time video during testing for security purposes. Thanks to its built-in internet protocol suite, every aspect of control unit device can be controlled remotely from anywhere around the world. Last but not the least, It has support for Android tablets permitting to control and monitor your testing equipment remotely.
cervical sampling brush for HPV test brush or swab is optional 5ml/10ml/20ml cell preservation solution optional
Product introduction: CD series nucleic acid extractor is a nucleic acid extraction and purification system for DNA/RNA introduced by our company. It realizes the transfer of magnetic beads/samples through adsorption, transfer and release of magnetic beads by magnetic rod and magnetic rod sleeve, and complete automatic extraction and purification operation. The operation is automatic, fast and simple, using special deep orifice plate and magnetic rod sleeve. CD32 can operate 1-32 samples(CD48 can operate 1-48 samplesï¼?CD96 can operate 1-96samples ) at the same time. With different kinds of magnetic beads nucleic acid extraction reagents, our extractors are able to extract animal tissue, plant tissue, blood and humor samples. It is mainly used for the extraction and purification of nucleic acid in human samples. Scope of application: This product is suitable for nucleic acid extraction and purification of serum, plasma, pharyngeal swabs, anal swabs, feces, reproductive tract secretions, explants, urine, sputum, etc. It can be used in clinical gene amplification testing laboratories, CDC centers for Disease Control and Prevention, laboratories of scientific research institutes, laboratories of medical colleges and universities, etc.
Product Introduction: Intended use: Used for transport and preservation of clinical samples of aerobic bacteria, anaerobic bacteria, hypotrophic bacteria, viruses and chlamydia. Not used for microbial identification and drug sensitivity tests. Storage condition: Storage at room temperature, away from light, environmental humidity < 80%, disposable test-tube products should be stored in 5-25 Product performance index: This product is uniform, no precipitation of gel solid; After sterilization, the pH of the medium should be 7.3±0.1 at 25 Sample requirements and applicable instruments: Suitable for laboratory equipment The collection, storage, handling and transportation of samples should be strictly aseptic to avoid contamination.
Disposable Sterile Nylon Flocked Collection Swab With Virus Transport Medium This product is mainly composed of flocked swab, virus transport medium, virus transport medium tube. It is mainly used for collection, transportation and preservation of oropharyngeal parts of respiratory and enteric virus such as influenza, bird flu, hand-foot-mouth disease, swine flu and so on. It is also suitable for the collection of other viruses, chlamydia, mycoplasma and ureaplasma urealyticum specimen. Nylon flocked swab: Nylon flocked head , ABS stick ,incision, EO Sterile --Swab head are made of safe materials with superior quality to the national standard, maximizing the collection and release of samples. --Swab rod are made of special easily broken materials that will not result in micro debris. Features ----Higher sampling rate ----Faster and complete release of samples ----Enhance diagnostic sensitivity ----Convenient handling and transportation Size: 10ml / 5ml / 2ml etc..
Non-Pyrogenic Low Retention Lab Racked Sterile Universal Dnase/Rnase Filter Pipette Tips Material: Medical grade PP material Size: 10uL 100uL 200uL 1000uL Absorption treatment: Low Retention Treatment Sterilization manner: Irradiation Sterilization Fits most brands and models of pipettors: Eppendorf, Thermo, Brand, Gilson, Rainin (Made in China) and Dragon, etc. Application: Fast and accurate pipetting processing widely used in molecular biology, clinical chemistry, biochemistry research. Other features: Sterilize, DNase & RNase free, Non-pyrogen (Endotoxin free)
CE Magnetic Bead Method Nucleic Acid Extraction and Purification Kit It's designed for the rapid, efficient and automatic isolation and purification of high quality virus nucleic acid from a variety of samples on the automatic nucleic acid extraction system. Features: 1): Rapid and Reliable: Fast procedures and easy to use 2): High Sensitivity 3): High Efficiency: â?¥ 95% of the nucleic acid can be combined. 4): Versatile: Nucleic acid of various virus, Hepatitis, etc. in different samples, such as Serum, Plasma, Whole blood, Swabs, Saliva, Body fluid, Tissue, Feces, BALF, etc. for a broad range of down stream applications. 5): Safe: Non-toxic
CE FDA Disposable Saliva Collection Kit It is suitable for collecting and preserving oral saliva samples at room temperature, widely used in virus detection, gene detection, cytology sample processing, virology cell culture, molecular diagnosis detection, saliva microorganism extraction, etc. Specification: A set includes 1 collection funnel, 1 sampling tube & 2ml storage solution. Packing: Solf blister packing.