Product description Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source. Technical index Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Electrical parameters - continued AC Voltage Output - continued Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
Commodity:Avobenzone CAS No. 70356-09-1 Molecular Formula C20H22O3 Molecular Weigh 310.39 EINEC No. 274-581-6 Specification Quality standard: USP36 Appearance Off-white powder Assay 95.0-105.0% Melting range 81.0~86.0 Impurities Any individual impurity: 3.0% The sum of all of the impurities: 4.5% Loss on drying 0.5% Packaging and storage: 1kg/aluminum foil bag. 25kg/barrel, pharmaceutical packaging barrel. Sealed, stored in dark, with a shelf life of 2 years. Reference dosage: The hygiene standards for cosmetics stipulate that the maximum amount added shall not exceed 5%, and the general dosage is 1-4%. Usage: Sunscreen agent-1789 is the most effective fat soluble UVA filter and is a safe and effective UVA sunscreen approved by the US FDA for sale on the counter. It can effectively block UVA, thereby increasing the SPF value of sunscreen products. It can improve the efficacy of sunscreen products when used in combination with UVB filters, and BL-200 has the best effect when used in combination with octyl methoxycinnamate. BL-200 can increase its stability in the product. It has an extremely effective protective and repairing effect on human skin. Application: This product is soluble in oil and can be formulated into a cream using the usual method. However, the product turns red when it encounters metal ions, so other components such as formula water should not introduce metal ions. The equipment should be made of pure stainless steel, and an appropriate amount of EDTA-2Na should be added to the formula water phase to chelate with metal ions.
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power 0.05% (0.01A-0.2A) Reactive power Apparent power Active energy
Product description Portable Three-phase Standard Meter is a portable reference standard meter used to test three phase meters and single phase meters, it designed to work both in the eld and in the laboratory. Technical index Portable Three-phase Standard Meter Electrical parameters Accuracy class 0.05% Voltage supply Range 5V-480V Error Display range 5.000000V-480.0000V Harmonic 2nd-63st Range 1mA-120A Error Display range 1.000000mA-120.0000A Active power
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit. Provide three-phase active power, reactive power, power factor measurement and display, can expand the measurement range, replaces old analogical meter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical voltmeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical ammeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Especially developed for indication and supervision of the three-phase circuit, replaces an analogical voltmeter, reducing installation manpower and optimizing the used one of spaces in the panel. Ideal for protection of three-phase networks is monitored and generally to own alarm superior and inferior. Protection of the parameters of programming by password.
Product Description Major technical data: Accuracy class: 1.0 Power consumption: 20 years. Main functions: 1) Measurement of 50hz for 3-phase active power 2) 4 tariffs and 8 time periods for user's option 3) RS 485 communication functions 4) Manual and remote control program, and remote-metering functions 5) To record the parameters automatically through CMRI. Features: 1) High accuracy, reliability, overload capability 2) Low power consumption 3) Smt technology and re-flow soldering technology 4) Light weight, small size, easy to install. Model: DTSF318/DSSF318 Standard: IEC 62052-11 IEC 62053-21 IEC 62056-21 Productivity: 100.000pcs/year.
DTSY1088 single phase integrated type keypad meter measures total active energy. It is STS certified and complies with the standards of IEC62052, IEC62053, IEC62055, IEC62056 etc . The Measurement and Control Unit (MCU) is BS standard complied and can be installed into meter box to prevent unauthorized operation. FEATURES 1.Easily configurable Prepaid & Postpaid mode . 2.Reverse energy measured in forward. 3.Easily configurable user friendly kWh. 4.Configurable LCD displaying items 5.Programming reading by optical 6.Communications between MCU and MSDS is 4G/3G/GPRS (MCU to DCU is RF/PLC ) 7.Real time measures voltage, current, frequency, active power, etc. 8.Events record with time stamp. 9.Open Protocol: DLMS/COSEM 10.Plug&Play Communication modules(RF/PLC/4G/3G/GPRS optional ) 11.Advanced AMI/AMR integration
DESCRIPTION Adopting large scale IC and SMT processes,the DTSD1088 DLMS meter is made to accurately total active/reactive energy,forward and reverse active/reative energy and maximum demand.And in real-time it also measures and takes in process parameters like active/reactive power,apparent power,Voltage,current,power factor,frequency and so on,and implements time-of-use control,automatic stroge of reading-day demand,and records load profile and events.And with infrared,RS485,PLC communications equipped,the DTSD1088 DLMS meter is an ideal device to realize time-of use energy measurement and efficient processing in ease.It complies with applicable standards of IEC62052-11,IEC62053-21,IEC62053-61,IEC62054-21,IEC62056-61,IEC62059-11,IEC62059-21. FEATURES 1. Energy measurement (separate and total):Forward and reverse,active,four-quadrant,time-of use,sub-phase. 2. Demand record 3. Real-time parameters 4. Data archive 5. Data freezing 6. Events record 7. Optional infrared,PLC,M-BUS,Ethernet,GPRS communication
DESCRIPTION DTSD1088 three phase multifunctional meter is made to accurately measures total active/reactive energy, forward and reverse active/reactive energy and maximum demand. And in real-time it also measures and takes in process parameters like active/reactive power, apparent power, voltage, current, power factor, frequency and so on, and implements time-of-use control, automatic storage of reading-day demand, and records of load profile and events. DTSD1088 meter realizes time of use energy measurement and efficient processing in ease. It complies with applicable standards of IEC62052-11, IEC62053-21, IEC62053-23, IEC62053-661, IEC62054-21, IEC62056-61, IEC62059-11 and IEC62059-21. FEATURES 1.Customized meter design for Finland Utility. 2.Special terminal block connection for easy wiring. 3.Terminal cover &front cover with detecting features. 4.With backup battery for RTC. 5.Load Profile(Optional) 6.MD measurement 7.Over-load protection: Automatic power-off as load exceeds the specified value(optional) 8.With optical communication port(IEC1107) 9.Open protocol: DLMS/COSEM(Optional)
DESCRIPTION DTSD1088 three phase multifunctional meter is made to accurately measures total active/reactive energy, forward and reverse active/reactive energy and maximum demand. And in real-time it also measures and takes in process parameters like active/reactive power, apparent power, voltage, current, power factor, frequency and so on, and implements time-of-use control, automatic storage of reading-day demand, and records of load profile and events. With infrared, RS485, PLC and GPRS communication equipped, DTSD1088 meter realizes time of use energy measurement and efficient processing in ease. It complies with applicable standards of IEC62052-11, IEC62053-21, IEC62053-23, IEC62053-661, IEC62054-21, IEC62056-61, IEC62059-11 and IEC62059-21. FEATURES 1.Functional LCD displays(menu driven, scrolling function, IR remote control mode) 2.Events record: Power-on/power-off (latest ten time), power quality monitoring(10 times), meter cover open(10 times recorded and can be read by MDM software). 3.Load curve recording: Active/reactive energy, voltage(3 phases), current(3 phases), power factor(3 phases) and time stamp(DD/MM/HH/YY) 4.External relay 5.Over-load protection: Automatic power-off as load exceeds the specified value(optional) 6.RTC, broadcast time synchronization via communication interface(could be set by GPS time via the MDM) 7.Optional multi-communication: PLC based on OFDM according to CENELEC standards(A-band), GPRS(SIMCOM-chip), RS485, integrated M-Bus(extended connection to gas and water meters) according to OMS standard. 8.Open Protocol: DLMS/COSEM 9.Advanced AMI integration (Optional)
194Q is a high-end multifunction power analyzer manufactured by Blue Jay. higher measurement accuracy and powerful functions. With its four direct access keys and TFT displays friendly full text interface helps user operate device more easy in 3P3W or 3P4W LV installation. All monitored data is available via a digital RS485 communication port running Modbus Protocol. It can be used as a data gathering device for an intelligent Power Distribution System or Plant Automation System. Provide Harmonic measurement with multi-tariff record user can easy establish accounting standards for different time. Max 52th harmonic individual monitor let user clear grasp of the present electrical grid quality.
1.Starting test and creeping test 2.Measuring the different constant meters synchronously. 3.With the protect function of overload, short voltage circuit and open current circuit. 4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test. 5.The stored testing data can be transferred to multi-format for other program using
Features: 1. Check the error of active and reactive of watt-hour meter at the same time, and meanwhile check the error of main and secondary meter in the same circuit. 2. Display the electrical constants such as: voltage, current, power, power factor, phase and frequency and etc. 3. Measure ct ratio, wave form display. 4. Measure 2-51 voltage and current harmonics. 5. Judge wrong wiring. 6. Measure the baud rate for multi-function energy meter and meter number reading. ¦ct secondary loading function. 8. Automatically correct the clamp error.
.1 Description DEM8900-1/DEM8900-2/DEM8900-3 (short form for DEM8900) is designed by adopting the updated microprocessor and digital signal processing technology, which can be applied for monitoring the electrical system. DEM8900 can measure and analyze the real time electrical parameters, such as I,kWh,kvarh., Meanwhile, DEM8900 has functions of multi-tariff,RS485 communication ( MODBUS protocol),analog output, remote input and electrical pulse output. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured, and tested in accordance with Quality Assurance System ISO 9001. 1.2 Measured parameters Note 1. DEM8900-1 measure current, active energy, active power (optional, with analog output) 2. DEM8900-2 measure current, reactive energy, reactive power (optional, with analog output) 3. DEM8900-3 measure Current, active energy, reactive energy, active/reactive power (optional, with analog output) 1.3 EMC and Safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
Overview: The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion:Both voltage and current
Overview: The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion: Both voltage and current