We sell current transformers. Please contact me for quotation.
Tarpaulin, tarp, pe tarp, frp, grp, grating, pultruded, composite, frp rebar, panel tanks, pond liner, geomembrane, junction box, truck cover, boat cover, tent, camping, current transformers, indoor current transformers, outdoor transformers, switch gears, oil filled tank type transformers, wound primary type transformers, bar type transformers, window type transformers.
The whole production line are made SUS304 stainless steel ,with food safety standards.The use of high pressure bubble cleaning ,when the bubble is released in water,the material will be irregular strong turnover movement ,stirring effect .Effectively separate surface impurities to avoid damage to materials by touching ,knocking and scratching . Scope of application :clean vegetable processing ,central kitchen ,large dining canteen,catering chain ,food factory ,etc .
current tranformer LJB1 Deyang YOYIK is a strong technical force, first-class product quality, brand reputable large-scale mechanical and electrical equipment Limited. Company products covered a wide range of products sold worldwide, a number of users trust. Acting foreign first-class brand, EATON VICKERS, star, and so on products. Guarantee genuine, the spot sale. #DF-current tranformer LJB1-DF Sound wave receiver DZXL-32A Starting Valve Displacement Sensor TDZ-1B-03 potentiometer is a transducer TDZ-1E-12 LVDT Sensor TD-1GNK-350-15 Magnetoresistive probe CS-1 G-090-05-01 Bolt electric heating rod ZJ-20-T12(A) Bolt electric heating rod ZJ-16.5-T1A HP LVDT SPRAY POSITION SENSOR BY PASS B151.36.09.04.10 PPROACH SWITCH INDUCTIVE PROXIMITY SENSOR LJ12A3-4-Z/BY Electrode 2401B Bolt electric heating rod ZJ-20-3A Eddy Current Sensor PR6422/001-101 Sensor Unit FMU41 G2 magnetic pickup sensor price 70085-1010-428 level transmitter 3051DP2A22A1AB4HR5 Reducer(with motor) SR-101V LIMIT SWITCH YBLXW-5/11G2 Differential pressure transducer RC861CJ097JYM Eddy Current Sensor PR6425/010-111 non contact displacement sensor DET-35A Sensor DF312580-90-01-02 Sensor and cable CWY-DO-815004 Steam Turbine Pressure Switch 396723-SA6B2530-0INHG SPEED SENSOR A5S11N3/200-5T Transducers FPD-2 (0-75mV/4-20mA, AC127V) Eddy Current Sensor PR6422/001-111 lube oil pressure switch PS531SPP10/BB32N3 Close switch E2E-X10ME1 transmitter LJB1-1000A/10V Low filling level gauge EFA16B1H2 LVDT transmitter XCBSQ-02/150-01-12 Vibration speed sensor HD-ST-3 LVDT vavle IV 2000TDZ-A Keypad Board SY-PANEL1-WHEEL (V1.2) contactless position sensor DET200A AD Change Card AC6682 Weighing Transducer STC-250 Limit Switch WLGCA2-2 proximity transmitter TM0180-A07-B00-C05-D50 Extension cable WT0181-A80-B00 lvdt precision DET-1000B Ignition XDH-20C LVDT snesor CCH02A.319Z-1 high temperature differential pressure transmitter 3051CD1A2B21AM5B4Q4 low rpm tachometer HY-TACH temperature thermometer WTYY-1021 Contact block 3SB1400-0A inductive displacement sensor DET-25A DC SIGNAL CONVERTER M5VF-AA-R variable displacement transducer TDZ-1E-012 0-275 SYNCHRONISER SID-2CM/50-N-E-N-W Bolt electric heating rod ZJ-18-430 magnetic displacement sensor ZDET50A lubrication oil tank oil level indicator CCH02A.427Z-2 Stainless pressure vacuum gage ZJTFXC-150 lvdt encoder B151.36.09.04.15 LVDT Sensor K156.36.06.007 TRANSMITTER AX410/500011/STD Operation Board GP LVDT transmitter XCBSQ-01/250-01-01 Rectifier bridge cooling fan GDRM42 current tranformer LJB1 ZYR-DFYL-2025-2-6
1. DC immune CT with good DC error ; 2. High precision: 0.2, 0.1,0.05 Class, 3. Good linearity; 4. Max Current:6A,10A,30A,40A,60A,80A,100A,120A,160A,200A ; 5. Ratio :1000:1; 2000:1 or 2500:1 ; 7. Pin connection/ PCB mounting ; 8. It applied in Electricity meters .
DC immune Current transformer for Electricity meter -Adopted high permeability core, high accuracy , good linearity; -Anti-combustion plastic case ; -Encapsulated with epoxy resin with strong insulation ability; -DC immune function with good DC error , conform to IEC 62053-21; - Customised shield to against the external magnetic field .
KF series split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor voltage. These CTs can be mounted without removing existing cables for easily installation.
main parameter of 69kv CT Rated current ratio: 2000/1600/1500/1200/1100/800/500/400/300 : 5 A Rated output capacity of each corresponding ratio: 200/160/150/120/110/80/45/35/25 VA Winding accuracy class: 0.2/5P20/5P20/5P20 CNMEs business activities cover national and international engineering, Generation Stations, Electrical Engineering Equipment, all kinds of electrical equipment, Test And Design and so on. The activities consist of the industries of high voltage power transmission and distribution, diesel power generation, thermal power generation, Transformer Test Laboratory Design, Electrical Lab Design And Solution, Power Plant Design and so on.
These Current Transformers are manufactured in Wound Primary type and Window type construction. It is manufactured using Automatic Pressure Gelation casting and Vacuum Casting Technique. It ranges from 3.3 kV to 33 kV.
Resin cast current transformers are available for metering and protection application. These current transformers are mainly fabricated according to client’s specification. Ct coils are encapsulated in cast resin (polyester / epoxy). Secondary terminals are provided with either screws or studs. The main insulation between primary and secondary and earth is obtained by this epoxy resin. These transformers are of compact design with high mechanical and electrical properties. These are non-hygroscopic and hence give very good insulation properties even in given humid conditions. General particulars Rated voltage: 11 kv Rated primary current: 100 a Rated secondary current: 1a or 5a Rate burden: 5va Rated frequency: 50hz Accuracy class: 0.5 or 0.5s Temperature: as per is-2705/1992 Highest system voltage: 12kv Insulation level: 28kvrms/75kv(p) Stc: 13.1ka for 1 sec Continues thermal current: 1.2 times of rated current Core material: crgo Copper wire material: enameled wire as per is-4800 part-4 or iec-317 Insulation class/material: epoxy resin Secondary terminal: m5 brass bolt with nut &washer or m5 threaded bush with screw &washer Primary terminal p1 & p2 size and material Mounting base: ms 5mm thick zinc plated Rountine test :as per is-2705/1992
The initial magnetic permeability and temperature stability between nanocrystalline soft magnet alloy and permalloy are similar. Under the same conditions of core sizes and characteristics, the weight of the former is much lighter (about 1/3 lighter), cost much lower. Applications: Electronic kwh meter Precise power meter Overcurrent protection in mechanical control apparatus Current control in industrial automation Good thermal stability Paper ctn
We are one of the leading trader and supplier of world class range of Resin Cast Current Transformers that are procured from our certified vendors of the market. These transformers are fabricated using the finest grade raw material and sophisticated technology at vendors’ end. Our offered products are widely demanded among clients due to their quality attributes like high performance, user friendly interface, longer service life and compact design. Our offered transformers are carefully examined on various parameters by our vendors to ensure their flawlessness. Specifications: Resin cast current transformers up to 33KV class As per mutual discussion
VoltageBurdenRange 1-ph.Tape wound & resin cast Upto 1100 v Prim:1 a to 10000 a; sec: 5 or 1a Bar primary ctsMetering & 2.5 va to 30 vaCl. 0.2/0.5/1.0/3.0/5.0 Protective2.5 va to 30 vaCl. 5p3/5p5/5p10/5p15/5p20 ProtectiveVk & rct reqd.Cl.Ps 3-ph.Tape wound & resin cast Upto 1100 v Prim: 200 a to 5000 a; sec: 5 or 1a Bar primary cts Metering & 2.5 va to 30 vaCl. 0.2/0.5/1.0/3.0/5.0 Protective2.5 va to 30 vaCl. 5p3/5p5/5p10/5p15/5p20 ProtectiveVk & rct reqd.Cl.Ps 1-ph.Tape wound & resin cast Upto 1100 v2.5 va to 15 vaPrim:1 a to 150 a; sec: 5 or 1a Wound primary cts Metering & Cl. 0.5 / 1.0 / 3.0 Protective Cl. 5p10 3-ph.Resin cast Upto 1100 v2.5 va to 5 vaPrim:50 a to 100 a; sec: 5 or 1a Wound primary cts Metering Cl. 0.5 / 1.0 1-ph.Resin cast Upto 1100 vSuitable for cablesSuitable for relays Core balance ctsProtectiveUpto 33 kvOf all makes 1-ph.Special cts Upto 1100 v Tape wound & resin cast Interposing & summation cts 1-ph.Resin cast cts Upto 6.6 / 11kv5.0 va to 15 vaPrimary : 1 to 3000 ampers Metering & Sec: 1, 5 and some special required ampers. Protective Cl. 0.2/0.5/1.0 Cl. 5p3/5p5/5p10/5p15/5p20 Cl.Ps As per mutual discussion
Accuracy class- 0.5 Burden- as oer customer requirement
The high-voltage electric energy measurement devices of power plants and substations and the electric energy measurement devices of a large number of users are related to the interests of power generation power transmission power supply and multiple parties of users. In order to ensure accurate measurement the inspection must be carried out in accordance with SD109 "Inspection Regulations for Electric Energy Measurement Devices" and DL / T448-2000 "Technical Management Regulations for Electricity Measurement Devices".
Features: Wide range of system current Ratings Hinged terminal cover Various mounting options like DIN rail mounting, Wall mounting Terminal with self lifting screw with dual connection facility giving access from both sides of transformers
Main Feature: 1.Small size, low cost 2.High secondary turns 3.Secure locking hinge Model No.: MEWOI-CT23CT55CT58,CT88,CT410,CT610,CT816 Name: MEWOI-CT23CT55CT58,CT88,CT410,CT610,CT816 Split Core Current Sensor/Transformer SPECIFICATION Model Number: MEWOI-CT23CT55CT58,CT88,CT410,CT610,CT812,CT816 Apply to: GB28040 and IEC68169 Rated Voltage : 0.66/0.72KVrms Primary Current input : 100-5000Arms Secondary Output: 5Arms/1Arms Insulaiton Strength: 2KVac/min Insulation Resistance DC500V/100MΩ Working frequency 50-400Hz Operating Temperature-25to 50 Storage Temperature -30to 70 MEWOI-CT23CT55CT58,CT88,CT410,CT610,CT812,CT816 series of split type current transformers are mainly used in industrial urban network, agricultural network transformation project, easy installation, no need to disassemble any cable or bus-bar circuit, and support electrified operation, not affect the normal power consumption of users, save a lot of manpower and material resources for the user transformation project, and improve the efficiency of transformation. This series current transformer can be used in conjunction with relay protection, measurement and metering devices. At present, it is widely used in transformation projects such as semiconductor industry.
LZZBJ9-12A1(A2) current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omni-directional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50- 60Hz and highest voltage for equipment 7.2 kV /12 kV . Main technical parameter 1. Rated voltage: 6.6 kV or 11 kV etc. 2.Rated secondary current: 5A?1A 3.Rated insulation level: 7.2/20/60 kV or 12/28/75 kV 4.Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers 5.Other technical parameter pls see as follows Rated transformation ratio(A) Accuracy classes combination Rated output(VA) (ALF) (FS) Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2(S)/0.2(S) 0.2(S)/0.5 0.2(S)/10P 0.5/10P 0.2S/0.5/10P 0.2/0.5/10P 10 15 15 15 10 15 20 5 (10) 150I1n 375I1n 300/5 31.5 80 400/5 31.5 80 500/5 40 100 600/5 50 125 800/5 20 63 125 1000/5 80 160 1200~1500/5 80 160 1500~2000/5 100 160 2000~3150/5 130 160 Rated transformation ratio(A) Accuracy classes combination Rated output(VA) (ALF) (FS) Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2S//0.5/ 10P 0.5/0.5/10P 10 15 15 15 20 10 15 5 (10) 150I1n 375I1n 300/5 31.5 80 400/5 31.5 80 500/5 40 100 600/5 50 125 800/5 63 125 1000/5 80 160 1200~1500/5 80 160 1500~2000/5 100 160 2000~3150/5 130 160 Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Factory price vegetable current cleaning machine The whole production line are made SUS304 stainless steel ,with food safety standards.The use of high pressure bubble cleaning ,when the bubble is released in water,the material will be irregular strong turnover movement ,stirring effect .Effectively separate surface impurities to avoid damage to materials by touching ,knocking and scratching . Scope of application :clean vegetable processing ,central kitchen ,large dining canteen,catering chain ,food factory ,etc .