GSB2 series Micro Circuit Breakers comply with IEC60898-1: Rated Isolation Voltage: up to AC500V Rated Voltage: 240V AC for 1P 415V AC for 2P, 3P and 4P Rated Current of Frame (A): 63A Rated Current (A): 1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Rated Ultimate Short-circuit Breaking Capacity (KA): 6 Rated Impulse Withstand Voltage or Uimp (KV): 4 Instantaneous Release: C or D Mechanical Life: 20000 times Grade of Protection: IP20 Connection Capacity: 1-25MM2 Frequency: 50Hz or 60Hz Poles: 1, 2, 3 or 4. Width of single pole: 18mm.
Pole number: 1,2,3P Rated voltage: 120/240V Rated current: 10,15,20,25,30,40,50,60A Interrupting Capability: 10KA Standard: US standard
Bis approval for isi marking as per latest is/iec 60898:2002 for assured quality and protection Green product – recyclable, low watt loss, free from hazardous material like cfc and silicon (rohs) Mcb with patented unique slr (slide latch-release) feature for tool free removal from din rail. It also allows individual mcbs to be removed from bus mounted assembly Ergonomically designed, with a user friendly lever for effortless switching To highlight exact switching position, easily recognizable color coded on-off is embedded on the attractive grey lever
* 1P, 2P, 3P, 4P * Rated Current In(A):1~125 * Rated Voltage Ue(V): 230/ 400 * Rated Frenquency(HZ): 50/60 * Rated Short Circuit Capacity Icn (A): 10000
A6 1P circuit breaker switch belongs to the advanced level of the nineties in the world. They have protective functions as shortage and overloading,and are used in lighting distribution system in industry,commerce and dwelling,and protect fractional electric motors.And they also have many merits of high protective grade(up to IP20),high breaking capacity,good reliability of sensitive action,convenient multi-pole assorting,long using life etc.They are mainly adapted to the circuit of AC50Hz, 230V in single pole,400V in double,three on four poles for protecting overload and shortage.Meanwhile,they are also used in turning on or off the electric apparatus and lighting circuit under the normal condition.
We can supply c45n mcb dz47 mcb, dz47le, c60n mcb, c65n mcb, ic65n mcb, merlin gerin mcb, lg mcb, abb mcb, mem mcb, legrand mcb, lg mcb, nt-50 safety breaker, s101 screw mcb, e4cb mcb, 200b mcb 200bz mcb, l7 mcb, nc-100h mcb, my mcb mt mcb mu mcb, sx mcb, bh mcb, hydraulic magnetic miniature circuit breaker Cm1 mccb cdm1, dpx mccb, hhb mccb, 3vl siemens mccb, am7 mccb, ns mccb, ds mccb, ea mccb, sa mccb, ab mccb, hfd mccb, 3ve mpcb, 3vu cb, gv Mpcb isomax s molded case circuit breaker (abb mccb) , nf-cs mccb(mitsubishi mccb), dpx mccb(legrand mccb), ns mccb (merlin gerin mccb) etc. Moulded case circuit breaker 1. Product net weight: 128g/pole 2. Packing quantity& weight: 12 pole /box, 20 box/carton, 240 pole/carton . 3. N.W: 22.5 kg/carton 4. G.W:24kg/carton 5. Packing measurement: inner box 22.5¡Á9¡Á8 cm, carton 45¡Á23.5¡Á33.5 cm ( ie 0.036 cbm)
1P 250V DC solar mini circuit breaker Description: PQL7 PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
egrand mcb series Miniature Circuit Breaker Application Legrand miniature circuit breaker is mainly suitable for overload and short circuit protection. It is especially used for illumination and distribution in industry and commerce, etc. it is of pleasing outlook & high breaking capacity, reliable performance, high inflammable resistance and shock resistance for long service life. It is within the circuit of AC 50/60HZ, rated voltage of single pole up to 230V, two, three or four poles up to 400V. It can also be for an unfrequent switchover of the circuit and illumination under normal conditions
BKN Miniature Circuit Breaker Application BKN series circuit breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50HZ/60HZ single-pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
Product Feature Model: EBS1B-125 MCB Standard: IEC 60947-2 Rated current In (A): 32, 40, 50, 63, 80, 100, 125 Rated voltage Ue (V):230/400 Poles:1P, 2P, 3P, 4P Rated insulation voltage Ui (V): 500 Rated impulse withstand voltage (V): 6000 Rated breaking capacity: 10kA Rated frequency: 50/60 Hz Trip characteristic:B: (3~5) C: (5~10) D: (10~20) Thermal operating limit: (1.13~1.45) Mechanical life: 20 000 Electrical life: 4000 Mount: on 35mm DIN rail Packaging Standard export carton
DZ47-63 Miniature circuit breaker has novel structure,reliable performance,high breaking capacity,pleasing outlook and small size,Its case and items are adopted by high fire-resistant and shockproof plastics,It mainly used in the building office,house and similar building for illuminating at AC 50 Hz/60 Hz,rate voltage below 230/ 400 V,rated current below 63 A,distribution circuit and equipment overload,short circuit protection.It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of IEC 60898 and GB 10963.1 standards.
miniature circuit breaker lockout with aluminum: 1.suitable for MCB; 2.0.5g/PC; 3.100PCS/box; info@new-pv.com www.new-pv.com
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: C/D The number of poles: 1P+N Rated short circuit breaking capacity: Icn 4.5kA Rated working current: In 6-40A Rated working voltage Ue : AC 230V Rated operating frequency : 50/60Hz Rated insulation voltage Ui: 500V Rated impulse withstand voltage Uimp: 4kV Mechanical/electrical life: 10000/4000 Times
1P Miniature Electric DC Circuit Breaker 60A Single Phase Main Circuit Breaker Please contact us for further information!
Ishcanto ixd47-63 series miniature circuit breaker is made of plastic shell, operating mechanism, contact arc system, tripping mechanisum and other components. The shell is made of high-strength special plastic, with strong impact capability and light wieght. Feature: short circuit protection Isolation function Overload protection Control
SH200 Miniature Circuit Breaker Resin Type, ,Sh200 Mcb
Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment..We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
4p 1000V DC Solar Mini Circuit Breaker Description: PQB1Z-63 4P PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A (can be extended to 125A) Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current : A/AC
Standard: IEC/EN61008-1 GB/T16916.1 Release Type of Leakage Protection: Electronic /Electromagnetic The number of poles: 1P+N/3P+N Rated limit short circuit breaking capacity (Inc): 6kA Rated working current (In): 16-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated impulse withstand voltage (Uimp): 4kV Rated residual operating current : 10/30/100/300mA Mechanical/electrical life: 4000/4000 Times Type of residual current: A/AC