1. Introduction JCZ5 12kv vacuum contactor HVJ6-12 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 12KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of circuit equipment. 2. Service condition a) Ambient air temperature: -25- +40. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95,monthly mean not higher than 90; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5. Main technical parameters Rated voltage: 12000 v Control circuit: 110V 220V Rated current: 200A 400A 630A Contacts separation: 5+1-0.5 mm Over travel: 1.5±0.5 mm Main circuit power frequency withstand voltage: 42000 v Auxiliary circuit power frequency voltage withstand: 2500 v Control circuit power frequency voltage withstand: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30104 Weight: 32KG
1. General HVD32 ZW32 12kv 630A This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system. 2 . Main technical parameter Rated voltage: 12 kv 1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv Rated current: 630A Rated short circuit breaking current: 12.5KA, 16KA, 20KA Rated short-circuit current (peak): 31.5KA, 40KA, 50KA Rated peak withstand current: 31.5KA, 40KA, 50KA 4s rated short time withstand current: 12.5KA, 16KA, 20KA Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation) Closing time: 30-60 ms Opening time: 20-40 ms Rated short circuit breaking current breaking times: 30 times Mechanical life: 10,000 times Secondary circuit 1 minute power frequency withstand voltage: 2000 v Energy storage motor rated power: 40 w Energy storage motor rated voltage V: DC220/110 Rated closing operation voltage v: DC220/110, AC220/110 Rated switching operation voltage v: DC220/110, AC220/110 Electric energy storage time: 8 s
The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long maintenance is simple .no explosion dangerous no contaminate and the noise is low . The pack vacuum contactor can operate the ebery kind of electric appliances equipments, and fuse match f-c cabinet
HCJ5 1.14kv 250A vacuum interrupter for vacuum contactor 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environment 2. Vacuum Tube main technique parameter Rated voltage: 1.14 kv Rated current: 250A Rated making current: 2500A Rated breaking current: 2000A Limiting breaking current: 2500A Rated short-time withstand current: 2000A Rated short-time withstand voltage: 10 kv Mechanical life: 1000000 times Breaking operations AC3: 150000 times Breaking operations AC4: 6000 times Automatic closing force of the contacts: 50±10 N Force required to hold contacts open at full stork: 70±10 N Circuit resistance at lowest rated contacts force: â?¤120μΩ Limiting abrasion of contacts: 2 mm Storage life: 20 years Internal gas pressure: â?¤1.33Ã?10-3 Pa
HCJ3 7.2kv 400A vacuum interrupter for vacuum contactors 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long maintenance is simple .no explosion dangerous no contaminate and the noise is low . The pack vacuum contactor can operate the ebery kind of electric appliances equipments, and fuse match f-c cabinet 2. Vacuum Tube main technique parameter Rated voltage: 7.2 kv Rated current: 630A Rated making current: 4 KA Rated breaking current: 3.2 KA Limiting breaking current: 4 KA Rated short-time withstand current: 3.2KA Rated short-time withstand voltage: 32 kv Rated lighting impulse voltage: 60 kv Circuit resistance at lowest rated contacts force: â?¤80μΩ Electrical life: 250,000 times Mechanical life: 500,000 times Closing force due to bellows and atmosphere: 70±20 N Force required to hold contacts open at full stroke: 100±30 N Limiting abrasion of contacts: 3 mm Internal gas pressure: â?¤1.33Ã?10-3 Pa Storage life: 20 years
HCJ3 7.2kv 630A vacuum interrupter for vacuum contactors 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long maintenance is simple .no explosion dangerous no contaminate and the noise is low . The pack vacuum contactor can operate the ebery kind of electric appliances equipments, and fuse match f-c cabinet 2. Vacuum Tube main technique parameter Rated voltage: 7.2 kv Rated current: 630A Rated making current: 6.3KA Rated breaking current: 5.04KA Limiting breaking current: 6.3KA Rated short-time withstand current: 6.3KA Rated short-time withstand voltage: 32 kv Rated lighting impulse voltage: 60 kv Circuit resistance at lowest rated contacts force: â?¤80μΩ Electrical life: 250,000 times Mechanical life: 500,000 times Closing force due to bellows and atmosphere: 70±20 N Force required to hold contacts open at full stroke: 100±30 N Limiting abrasion of contacts: 3 mm Internal gas pressure: â?¤1.33Ã?10-3 Pa Storage life: 20 years
HCJ5 1.14kv 1000A vacuum interrupter for vacuum contactor 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environmen 2. Vacuum Tube main technical parameter Rated voltage: 1.14 kv Rated current: 1000 A Rated put through current: 10000A Rated breaking current: 8000A Limiting breaking current: 10000A Rated short-time withstand current: 8000A Rated short-time withstand voltage(1 min): 10 kv Mechanical life: 1000000 times Rated breaking time AC3: 150000 times Rated breaking time AC4: 6000 times Automatic closing force of the contacts: 70±20 N Force required to hold contacts open at full stork: 90±20 N Contact automatic blocking ability loop electrical resistance: �80μΩ Contact-wear allowance thickness: 2 mm Shelf life: 20 years Internal gas pressure: �1.33�10-3 Pa
JCZR 7.2kv 12kv Indoor Vacuum Contactor-Fuse Combination Electric Appliance General: This combination electric appliance may install in the switch cabinet to form the F-C loop, use with the integrated protection device. It is used for loading of the switching on and switching off the power pant as well as the industry and mining enterprise, dropout AC high-tension motor, the transformer, capacitor and so on, and it has overload, short circuit protection function. This combination electric appliance may use in AC 50 HZ three-phase power systems. Technical Data: 1. Main Technical Parameter see Table 1. Rated voltage: 7.2 kv / 12 kv Power frequency withstand voltage phase to phase, to earth: 32 kv / 42 kv Power frequency withstand voltage the fracture impact withstand voltage(fracture): 60 kv / 75 kv Fuse rated current A: 25-250 / 25-250 Prospective short circuit breaking current KA: 50 / 50 Prospective short circuit making current(peak value) KA: 130 / 130 Prospective short circuit withstand current( peak value) KA: 10 / 10 Rated short time withstand current( effective value) KA: 4 / 4 Rated short circuit duration S: 4 / 4 Rated making current KA: 4 / 4 Rated breaking current KA: 3.2 / 3.2 Limit breaking current KA: 4.5 / 4.5 Contactor distance between fixed and moving contact mm: 4.5 / 5 Contactor over-travel mm: 1.5 / 1.5 Mechanical life times: Model J:100,000; Model D:300,000 / Model J:100,000; Model D:300,000 Closing coil Rated operation voltage(V): DC220,DC110 Opening coil Rated operation voltage(V): DC220,DC110 Holding coil Rated operation voltage(V): DC220,DC110 Closing coil power: 1200 W Holding coil power: 15 W Opening coil power: 80 W Closing coil Normal work voltage range: 85%-110% rated voltage Holding coil Normal work voltage range: 85%-110% rated voltage Opening coil Normal work voltage range: 60%-120% rated voltage
HVJ30 1.14kv vacuum contactor 1000A 1250A HVJ30-1.14/1000?1250 series AC vacuum contactor is applicable for AC 50HZ power system of rated voltage 1.14KV and rated current up to 1000 A~1250Ato open and close circuit, start and control AC motor frequently. It is suitable for composed magnetic starter with various protective devices (JDB electronic integrated protector, JR9 type over current protection device, resistance-capacitance absorbers). It is particularly suitable for compose a explosion-proof magnetic starter and large mineral switchgear. Rated voltage: 1.14 kv Rated current: 1000A 1250A Making capacity(A): 5000(100 times) Breaking capacity(A): 4500(10 times) Limit breaking capacity(A): 5000(3 times) Electrical life times(AC3): 600,000 times Electrical life times(AC4): 6,000 times Mechanical life times: 1,000,000 times Rated operating frequency (AC3): 600 times /h Rated operating frequency (AC4): 120 times /h Short-time operating frequency(20s): 1000 times /h Contacts separation: 2.8±0.1 mm Over travel: 1.0±0.1 mm
Vacuum Interrupters TJ-7.2/400 The Interrupter adopts ?one shut technolog ceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields
Vacuum Interrupters TJ-3.6/630 The Interrupter adopts ne shut technology, ceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields.
Vacuum Interrupters -TJ-1.5/3000A The Interrupter adoptsone shut technology ceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields
Vacuum Interrupters TJ-3.6/630 The Interrupter adopts ne shut technology, ceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields.
Vacuum Interrupters TJ-7.2/400 The Interrupter adopts �??one shut technolog ceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields
Vacuum Interrupters TJ-1.14/160A The Interrupter adoptsone shut technologyceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields.
Vacuum Interrupters -TJ-1.5/3000A The Interrupter adoptsone shut technology ceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields
Vacuum Interrupters TJ-1.14/1000B The Interrupter adopts one shut technology, ceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields.
Vacuum Interrupters TJ-12/400 The Interrupter adopts â??one shut technologyâ?�, ceramic shell, CuWC as the contact material;is characterized by high insulation, low stop-flow, strong blowout ability , long life, smallsize etc, and has advantages as easy to maintain, no explosion risk ,pollution-free and lownoise etc. Contactors assembled by it are used to control and protect the electricity transmission and distribution system in electrical, mechanical, chemical, metallurgy, mining and railway department, especially in frequent operation fields.
Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 25KA Rated short circuit making current(peak value): 63KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 25KA Rated withstand current(peak value): 63KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: �20μΩ Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 2000±200N Contacts bouncing duration at closing operation: �2ms Contacts re-bouncing clearance at opening operation: �2mm Synchronism of three phases: �1ms Items Value Rated voltage 12KV Rated current 1250A Rated frequency 50Hz Rated power frequency withstand voltage 42kV Rated lightning impulse withstand voltage 75kV Rated short circuit breaking current 25KA Rated short circuit making current(peak value) 63KA Breaking operations under rated short circuit breaking current 30 times Rated short time withstand current 25kA Rated withstand current(peak value) 63kA Rated duration of short circuit 4s Mechanical life 20000 times Closing force due to bellows and atmosphere 120±50N Force required to hold contacts opening at full stroke 190±50N Circuit resistance at lowest rated contacts force �20μΩ Storage life 20 years Limiting abrasion of contacts 3mm  Mechanical requiements of vacuum circuit breaker Items Value Clearance between opening contacts 11±1mm Average opening speed(Contacts closing position~75% contacts opening distance) 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position) 0.6±0.2 m/s Rated contacts pressure 2000±200N Contacts bouncing duration at closing operation �2ms Contacts re-bouncing clearance at opening operation �2mm Synchronism of three phases �1ms
HCJ5 1.14kv 1000A vacuum interrupter for vacuum contactor 1. Brief introduction The interrupter adoption porcelain and ceramics makes to insulate the outer shell. Contact is WCCu metal alloy material advanced technique of adoption Including bulk small. Breaking the abiliting strong the life span is long, maintenanle is simple, no explosion dangerous, no contaminate and the noise is low. It is extensive to used for coal mine , chemical engineering, Petroleum metallurgy etc. department, more than keeping with at the multifarious operation with the bad place usage of environmen 2. Vacuum Tube main technical parameter Rated voltage: 1.14 kv Rated current: 1000 A Rated put through current: 10000A Rated breaking current: 8000A Limiting breaking current: 10000A Rated short-time withstand current: 8000A Rated short-time withstand voltage(1 min): 10 kv Mechanical life: 1000000 times Rated breaking time AC3: 150000 times Rated breaking time AC4: 6000 times Automatic closing force of the contacts: 70±20 N Force required to hold contacts open at full stork: 90±20 N Contact automatic blocking ability loop electrical resistance: 80 Contact-wear allowance thickness: 2 mm Shelf life: 20 years Internal gas pressure: 1.3310-3 Pa