Chv-450/3.6(1.14) contactor has the same performance and function with baker ac contactor, while it's more aligned with chinese national standards on some parameter index, contactor has independent drive with insolating function and the ability of breaking short time current. It has current/voltage mutual inductor which can realise the zero-current-break and comprehensive protection function; adopt quick pipe connection mode which is easy to use and maintain; highly integrated with small size and compact structure.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb Wattage: 10W Blue UV light Lumen: 900-1000lm Color Temperature (CCT): 6500K Input Voltage: AC 90-130V & 220v-240V With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
CE Certificate CJX2 series 3P AC Contactor Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure. Application CJX2 Series AC contactor is mainly applies to the circuit of AC 50Hz/60Hz, and rated insulation voltage 660V. When use in AC-3, and rated operational voltage is 380V, rated current up to 630A, for long distance breaking circuit and frequently starting or control the motor. Combined with proper thermal overload relay can protect load circuit. Contactor can frequently start and control AC electromotor. Construction Features 1. Adopt build-in block system to mount auxiliary contractor block, air delay auxiliary contractor, thermal overload relay and so on, which can be combined into multiple derved series product. 2. Contactor has the advantage of Small volume, light, low consumption, long life and good safety. 3. Main contactor below 32A has 1N/C or 1N/O, there is 1N/C and 1N/O above 40A, Contactor can be assembled with F4, F8 auxiliary contact or time-delay block. 4. Contactor can not only use screw mounting, but also use 35mm(CJX2-09-95), 75mm (CJX2-40-95) and 2x35mm (CJX2-D115-170) international standard Din-rail mounting
1. General HVJ5 1.14kv 125A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 125A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36V, 110V, 220V, 380V Rated current: 125A Opening distance: 1.8±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 2000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10 S Remark: “Ie” is Rated current of main circuit.
CJT1 220V-380V air ac modular contactor is suitable for frequency 50HZ,rated insulation voltage up to 380V, rated operation current 10-150A. It is mainly used for making or breaking electric circuits at a long distance and for frequent starting and stopping and controlling AC motors. It is used in combination with thermal relay to compose a magnetic motor starter. The product accords with standard IEC 60947-4-1,GB14048.4
LP1-D series DC operated AC contactor is suitable for use in the circuits up to rated voltage 660V AC 50Hz or 60Hz,and in rated current 9-95A in AC-3/380V load circuits It for remote controlling circuit making,breaking and frequent starting AC motors It can also combine with the auxiliary contact group,air delayer,thermal relay devices etc
3TF Series AC low voltage Contactor is suitable for frequency 50/60Hz, rated insulation voltage up to 1000V, rated operation current 9~475A under AC-3 duty. It is mainly used for making or breaking and frequent starting& stopping electric circuit at a long distance. It can combine with the thermal relay to compose a magnetic motor starter. The product conforms to IEC60947-4-1.
Siemens, merlin gerin, abb, westinghouse, honeywell, ge, schneider, allen bradley, moeller, aeg, fuji, furnas, albright, lovato, benshaw, hager, l&t, brook, chint, danfoss, omron, teco, sprecher, stromberg, togami, joslyn clark, eaton, matsushita. Specific contactors, low voltage contactor, magnetic contactors, solid-state contactor, definite purpose contactors, modular contactor, low noise contactor, miniature contactor, standard contactor, contactors for special applications
Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups..
1. General HVJ5 1.14 kv 250A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1140V and rated current to 250A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 v Control voltage: 36V, 110V, 220V, 380V Rated current: 250A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 4500,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 60*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: “Ie” is Rated current of main circuit.
1. General HVJ5 1.14 kv 1000A AC vacuum contactor is designed for long-distance making and breaking of circuit, frequent starting and controlling of AC motors in the power systems, with AC 50Hz-60Hz, rated voltage of 1,140V and rated current to 1000A. It also can be equipped with thermal relay and all kinds of protection apparatus like electromagnetic starter, especially applied to explosion-proof starter and so on. 2. Main technical parameter Rated voltage: 1140 V Control voltage: 36 V, 110 V, 220 V, 380 V Rated current: 1000A Opening distance: 2±0.2 mm Over travel: 1±0.2 mm Final pressure: 30±3 N Main circuit power frequency voltage withstand: 4200 V Auxiliary circuit power frequency voltage withstand: 2500 V Control circuit power frequency voltage withstand: 2000 V Making capacity: 10Ie,100 times Breaking capacity: 8Ie,25 times Limit breaking current(A): 10000,3 times Electricity life times AC3: 60*104 Electricity life times AC4: 1.5*104 Mechanical life times: 300*104 Overload capacity: 8Ie 10S Remark: “Ie” is Rated current of main circuit.
1. CJX2-K LC1-K Three Phase ac mini contactor is suitable for use in the circuit up to the rate and frequent starting, controlling the AC motor. 2. The addition of auxiliary contact group to the contactor, combined with the proper thermal relay, can act to protect the circuit bound to overload. 3. The LC1-K Series AC Contactor complies with IEC947-2,VDE0660 and BS5452 .
CJX2-N LC1-N ac mechanical interlock contactor is suitable for using in the circuits up to the rated voltage 660V AC 50/60Hz, current 620A, for convertible controlling the motor. This mechanical interlocking device ensures contact changeover of the two convertible contactors. It conforms to IEC60947-4-1
Laundry soaps, detergent powder, bathing/toilet soaps, liquid detergent etc. tubular batteries, inverter, wall and floor tiles, stones, spices etc..We provide all sorts of in house shipping facilities along with our products, manufacturer
Waste Specification: European Classification: E46 EWC Code: 19.01.02 Basel Code: B10 10 The material is loose steel scrap processed through an incinerating plant for domestic waste followed by magnetic separation, fragmentized into pieces and consisting partly of tin coated steel cans. At a visual inspection, the material is fragmentized, with iron and steel parts, resulting partly cut or in shredded form. The stock appears heterogeneous and contains all kind of cut or dismantled steel parts such as sheets, bars, frames, wires, bolts and other iron/steel household residues. The incinerated scrap is eventually oxidized, due to the thermal and cooling treatments, that the material has been submitted to. The burnt scrap also contains minor slag parts, ash and iron oxide, due to the recovery process. Such components are inherent and adhere to the scrap surface. The total impurities, can be sorted, but not fully removed. The consignment does not contain any type of arms, ammunition, mines, shells, cartridges, radioactive contaminated, or any other explosive material in any form either used or otherwise. The collected stock, is stored in open air, on cemented flooring. Due to the scrap dimensions and the material conditions, this particular scrap, should be carefully evaluated first, by the end users, to confirm its adequate recovery ratio and its suitability to be re-melted in the electric arc furnace. Please feel free to contact us for further details
The Incinerated scrap or E46, is the by-product derived from the reprocessing of incinerated domestic waste. After the combustion process, the furnace output (IBA Incinerator bottom ash) is firstly washed, magnetically separated and screened to separate any no ferrous material. At a visual inspection, the material is fragmentized, with iron and steel parts, resulting partly cut or in shredded form. The stock appears heterogeneous and contains all kind of cut or dismantled steel parts such as sheets, bars, frames, wires, bolts and other iron/steel household residues. The incinerated scrap is eventually oxidized, due to the thermal and cooling treatments, that the material has been submitted to. The burnt scrap also contains minor slag parts, ash and iron oxide, due to the recovery process. Such components are inherent and adhere to the scrap surface. The total impurities, can be sorted, but not fully removed. The consignment does not contain any type of arms, ammunition, mines, shells, cartridges, radioactive contaminated, or any other explosive material in any form either used or otherwise. The collected stock, is stored in open air, on cemented flooring. It can be loaded loose in 20â?? heavy duty container. Please feel free to contact us for further details.
Product Type : ICUMSA 45 Material : SUGAR Polarisation : 99.80 % Ash Content : 0.08 % Solubility : 100 % dry and free flowing Radiation : within internationally accepted limits Color: Sparkling white Granulation : fine crystal Moisture : 0.8 % Max Magnetic Particles 4 mg / k So2 Content 70 mg / k Ash by electrical conductivity 0.04 % max ( on dry basis ) Sulphur dioxide 20 mg / kg min
Construction equipment (home improvement, electrical supply, pipes and fitting etc..), heavy machinery: mining equipment, excavator, drilling, and so on paper and packaging, production line: kraft paper, plastic and paper box, aluminum foil, plastic wrap, boxes, paper cups, take a way box and so on.. renewable energy: solar panels, inverter, photovoltaic chemical and raw material: soda ash, titanium, pe, ppe .Our company hangzhou xing ying technology co., ltd.(astrioglobal) also provides exporting, quality control, international logistics and consulting/negotiation.
Mini circuit breaker; earth leakage circuit breaker; moulded case circuit breaker; ac contactor; relay; magnetic starter.